Empty-bag technique for acrylic intraocular lens implantation using Healon5

被引:5
|
作者
Cionni, RJ
Temel, M
Marques, DMV
Marques, FF
机构
[1] Cincinnati Eye Inst, Cincinnati, OH 45242 USA
[2] Univ Cincinnati, Coll Med, Dept Ophthalmol, Cincinnati, OH USA
[3] Dept Ophthalmol, Marmais Mugla, Turkey
[4] ABC, Fac Med, Dept Ophthalmol, Sao Paulo, Brazil
来源
关键词
D O I
10.1016/S0886-3350(03)00673-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine how often the empty-bag technique (EBT) for injecting an acrylic foldable intraocular lens (IOL) into the capsular bag using Healon(C)5 (sodium hyaluronate 2.3%) will require a 2-compartment technique to remove the ophthalmic viscosurgical device (OVD) and compare this with that of a standard injection method using Healon5. Setting: Cincinnati Eye Institute and Ambulatory Surgical Center, Cincinnati, Ohio, USA. Methods: Forty-one eyes of 40 patients were randomly assigned to 1 of 2 groups. In Group A, standard capsular bag expansion was performed with Healon5 before implantation of an acrylic posterior chamber (PC) IOL. In Group 13, Healon5 was placed in the anterior chamber followed by balanced salt solution expansion of the capsular bag before acrylic PC IOL implantation. In all patients, complete OVD removal was attempted with the automated aspiration tip anterior to the optic (rock 'n roll technique). The number of patients in each group who required placement of the aspiration tip posterior to the optic for complete removal was compared. Early postoperative intraocular pressure (IOP) was also compared. Results: In Group A, 15 (75%) of 20 eyes required placement of the aspiration tip posterior to the optic for complete OVD removal and in Group B, 1 (0.05%) of 20 eyes. The postoperative IOP was similar in both groups. Conclusions: The EBT decreased the likelihood that a 2-compartment OVD removal method would be necessary when using Healon5 for acrylic PC IOL implantation. The limitations of this new technique must be fully understood before it is used.
引用
收藏
页码:453 / 456
页数:4
相关论文
共 50 条
  • [1] Clinical comparison of Healon5 and Healon in phacoemulsification and intraocular lens implantation: A randomized multicenter study
    Okazaki, T
    Oshika, T
    Eguchi, S
    Oki, K
    Yaguchi, S
    Bissen-Miyajima, H
    Ota, I
    Sugita, G
    Miyata, K
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U35 - U35
  • [2] Clinical comparison of Healon5 and Healon in phacoemulsification and intraocular lens implantation - Randomized multicenter study
    Oshika, T
    Eguchi, S
    Oki, K
    Yaguchi, S
    Bissen-Miyajima, H
    Ota, I
    Sugita, G
    Miyata, K
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (02): : 357 - 362
  • [3] Prospective randomized comparison of DisCoVisc and Healon5 in phacoemulsification and intraocular lens implantation
    Oshika, T.
    Bissen-Miyajima, H.
    Fujita, Y.
    Hayashi, K.
    Mano, T.
    Miyata, K.
    Sugita, T.
    Taira, Y.
    [J]. EYE, 2010, 24 (08) : 1376 - 1381
  • [4] Prospective randomized comparison of DisCoVisc and Healon5 in phacoemulsification and intraocular lens implantation
    T Oshika
    H Bissen-Miyajima
    Y Fujita
    K Hayashi
    T Mano
    K Miyata
    T Sugita
    Y Taira
    [J]. Eye, 2010, 24 : 1376 - 1381
  • [5] Physician experience using Healon5® in phacoemulsification and posterior chamber lens implantation
    Osher, RH
    Koch, PS
    Cionni, RJ
    Arshinoff, SA
    Jackson, AL
    Clifford, AE
    Stewart, JA
    Stewart, WC
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U161 - U161
  • [6] Intraocular pressure after bilateral cataract surgery using Healon, Healon5, and Healon GV
    Arshinoff, SA
    Albiani, DA
    Taylor-Laporte, J
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (04): : 617 - 625
  • [7] Healon5 sandwich technique for phacoemulsification in vitrectomized eyes
    Sudan, Rajeev
    Muralidhar, Rajamani
    Sharma, Vikas
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (01): : 18 - 20
  • [8] Surgically induced astigmatism after intraocular lens implantation using the bag-in-the-lens technique
    Gobin, Laure
    Tassignon, Marie-Jose
    Wouters, Kristien
    De Groot, Veva
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (06): : 1015 - 1019
  • [9] Clinical results after spherotoric intraocular lens implantation using the bag-in-the-lens technique
    Tassignon, Marie-Jose
    Gobin, Laure
    Mathysen, Danny
    Van Looveren, Jan
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (05): : 830 - 834
  • [10] Intraocular pressure after small incision cataract surgery with Healon5 and Viscoat
    Rainer, G
    Menapace, R
    Findl, O
    Georgopoulos, M
    Kiss, B
    Petternel, V
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (02): : 271 - 276