Imaging mechanism and effects of adsorbed water in contact-type scanning capacitance microscopy

被引:25
|
作者
Nakagiri, N [1 ]
Yamamoto, T [1 ]
Sugimura, H [1 ]
Suzuki, Y [1 ]
机构
[1] NIKON CO, CENT RES LAB, TOKYO 140, JAPAN
来源
关键词
D O I
10.1116/1.589168
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In order to demonstrate its unique capabilities, a combined microscope comprised of a scanning capacitance microscope and a contact mode atomic force microscope was used to image a buried structure. The atomic force microscopy images surface topography, while the scanning capacitance microscope simultaneously images buried structure. By applying a modulation technique, the voltage derivative of the capacitance (dC/dV) was used as a scanning capacitance microscope signal. The sample used for the demonstration was a silicon wafer with metal lines 4 nm in thickness covered by a 40-nm-thick layer of silicon oxide. The scanning capacitance microscope image was dependent on the bias voltage applied to the probe and the sample. Since the scanning capacitance microscope signal above the metal lines is zero, the bias voltage dependency of the contrast in scanning capacitance microscope images corresponds directly to the scanning capacitance microscope signal versus V at locations where the metal line is not buried. However, the bias dependency of the contrast did not agree with the scanning capacitance microscope signal observed between metal lines. A possible mechanism for the discrepancy between these bias dependencies is discussed based upon charge deposition on the sample surface caused by tip contact and lateral movement of the charges in the adsorbed water on the sample surface. (C) 1996 American Vacuum Society.
引用
收藏
页码:887 / 891
页数:5
相关论文
共 50 条
  • [1] Intermittent-contact scanning capacitance microscopy imaging and modeling for overlay metrology
    Mayo, S
    Kopanski, JJ
    Guthrie, WF
    [J]. CHARACTERIZATION AND METROLOGY FOR ULSI TECHNOLOGY, 1998, 449 : 567 - 572
  • [2] An ultrasonic contact-type position restoration mechanism
    Lu, Xiaolong
    Hu, Junhui
    Bhuyan, Satyanarayan
    Li, Shiyang
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (12):
  • [3] SCANNING TUNNELING MICROSCOPY IMAGING OF ALKANE BILAYERS ADSORBED ON GRAPHITE - MECHANISM OF CONTRAST
    THIBAUDAU, F
    WATEL, G
    COUSTY, J
    [J]. SURFACE SCIENCE, 1993, 281 (1-2) : L303 - L307
  • [4] Contrast reversal in scanning capacitance microscopy imaging
    Stephenson, R
    Verhulst, A
    De Wolf, P
    Caymax, M
    Vandervorst, W
    [J]. APPLIED PHYSICS LETTERS, 1998, 73 (18) : 2597 - 2599
  • [5] Effect of adsorbed water on the resolution of scanning capacitance microscopes
    Lányi, S
    [J]. SURFACE AND INTERFACE ANALYSIS, 1999, 27 (5-6) : 348 - 353
  • [6] Displacement current sensor for contact and intermittent contact scanning capacitance microscopy
    Biberger, Roland
    Benstetter, Guenther
    Goebel, Holger
    [J]. MICROELECTRONICS RELIABILITY, 2009, 49 (9-11) : 1192 - 1195
  • [7] Resolution enhancement in contact-type scanning nonlinear dielectric microscopy using a conductive carbon nanotube probe tip
    Ishikawa, Kenya
    Honda, Koichiro
    Cho, Yasuo
    [J]. NANOTECHNOLOGY, 2007, 18 (08)
  • [8] Contrast mechanism of ferroelectric domains in scanning capacitance microscopy
    Leu, CC
    Chien, CH
    Chen, CY
    Chang, MN
    Hsu, FY
    Hu, CT
    [J]. ELECTROCHEMICAL AND SOLID STATE LETTERS, 2004, 7 (10) : A327 - A330
  • [9] Pixel patterns for voxels in contact-type three dimensional imaging systems
    Son, JY
    Saveljev, VV
    Kim, SK
    Javidi, B
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2006, 45 (2A): : 798 - 803
  • [10] Scanning capacitance microscopy imaging of state-of-the-art MOSFETs
    Kleiman, RN
    O'Malley, ML
    Baumann, FH
    Garno, JP
    Timp, GL
    [J]. MICROSCOPY OF SEMICONDUCTING MATERIALS 1999, PROCEEDINGS, 1999, (164): : 615 - 624