An automatic monitor of formaldehyde in air by a monitoring tape method

被引:31
|
作者
Nakano, N
Nagashima, K
机构
[1] Riken Keiki Co Ltd, Itabashi Ku, Tokyo 1748477, Japan
[2] Kogakuin Univ, Fac Engn, Hachioji, Tokyo 1920016, Japan
来源
JOURNAL OF ENVIRONMENTAL MONITORING | 1999年 / 1卷 / 03期
关键词
D O I
10.1039/a900410f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An automatic monitor has been developed for measuring formaldehyde in air using a sensitive tape for formaldehyde. It is based on the color change of the tape on reaction with formaldehyde. The porous cellulose tape, containing silica gel as an absorbent and impregnated with the processing solution containing hydroxylamine sulfate, Methyl Yellow (pH indicator; pH 2.9-4.0, red-yellow), glycerin and methanol, was found to be a highly sensitive means of detecting formaldehyde and maintains a stable sensitivity. When the tape was exposed to a sample of air containing formaldehyde, the color of the tape changed from yellow to red. The degree of color change was proportional to the concentration of formaldehyde at a constant sampling time and flow rate, and it could be recorded by measuring the intensity of reflected light (555 nm). The tape could be used to detect down to 0.08 ppm (World Health Organization standard) of formaldehyde with a sampling time of 30 min and a flow rate of 100 mt min (-1). Reproducibility tests showed that the relative standard deviation of response (n = 10) was 3.8% for 0.1 ppm formaldehyde. The monitor is simple, specific, capable of unattended operation and is recommended for both laboratory and field operation.
引用
收藏
页码:255 / 258
页数:4
相关论文
共 50 条
  • [1] An automatic measurement of formaldehyde in air by a monitoring tape method
    Nakano, N
    Yamamoto, A
    Kawabe, T
    Nagashima, K
    [J]. NIPPON KAGAKU KAISHI, 1998, (07) : 506 - 510
  • [2] An automatic measurement of hydrogen cyanide in air by a monitoring tape method
    Nakano, N
    Yamamoto, A
    Kobayashi, Y
    Nagashima, K
    [J]. ANALYTICA CHIMICA ACTA, 1999, 398 (2-3) : 305 - 310
  • [3] An automatic monitor of ammonia in air using ammonia-sensitive tape
    Nakano, N
    Kawabe, T
    Isaka, M
    Nozima, Y
    [J]. BUNSEKI KAGAKU, 1998, 47 (07) : 423 - 428
  • [4] MONITORING OF FORMALDEHYDE IN AIR
    BALMAT, JL
    MEADOWS, GW
    [J]. AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1985, 46 (10): : 578 - 584
  • [5] DEVELOPMENT OF A MONITORING TAPE FOR THE DETERMINATION OF FORMALDEHYDE GAS IN FUMIGATION
    NAKANO, N
    ISHIKAWA, M
    KOBAYASHI, Y
    NAGASHIMA, K
    [J]. BUNSEKI KAGAKU, 1994, 43 (02) : 139 - 144
  • [6] DEVELOPMENT OF A MONITORING TAPE FOR PHOSGENE IN AIR
    NAKANO, N
    YAMAMOTO, A
    KOBAYASHI, Y
    NAGASHIMA, K
    [J]. TALANTA, 1995, 42 (04) : 641 - 645
  • [7] A new device for the automatic determination of formaldehyde in air
    Schlitt, H
    [J]. GEFAHRSTOFFE REINHALTUNG DER LUFT, 1997, 57 (02): : 75 - 78
  • [8] AN AUTOMATIC MONITOR FOR RADIO-IODINE IN AIR
    HOLFORD, RM
    [J]. HEALTH PHYSICS, 1968, 15 (02): : 168 - +
  • [9] AN AUTOMATIC MONITOR FOR MEASURING TRITIUM CONTAMINATION IN AIR
    SHAW, DF
    [J]. JOURNAL OF SCIENTIFIC INSTRUMENTS, 1955, 32 (05): : 178 - 180
  • [10] Automatic monitor for ammonia in clean room air
    Hase, U
    Matsuyoshi, Y
    [J]. NEC RESEARCH & DEVELOPMENT, 1998, 39 (02): : 95 - 100