Towards in vivo TLD dosimetry in mammography

被引:23
|
作者
Warren-Forward, HM [1 ]
Duggan, L
机构
[1] Univ Newcastle, Sch Hlth Sci, Newcastle, NSW 2308, Australia
[2] Newcastle Mater Misericordiae Hosp, Dept Radiat Oncol, Waratah, NSW 2298, Australia
来源
BRITISH JOURNAL OF RADIOLOGY | 2004年 / 77卷 / 917期
关键词
D O I
10.1259/bjr/91138314
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
While phantoms are used for quality control assessment of the mammography unit, in vivo dose measurements are necessary to account for the variation in size and composition of the female breast. The use of thermoluminescent dosimeters (TLDs) in mammography has been limited due to TLD visibility. The aim of this current investigation was to access the suitability of a paper-thin LiF:Mg,Cu,P TLD (GR-200F) for in vivo dosimetric mammography measurements. The visibility of GR-200F has been directly compared with LiF:Mg,Cu,,P TLDs (GR-200A) using a number of commercially available phantoms. The phantoms of thickness 2-5 cm were imaged over the range of tube potentials (24-28 kVp) used clinically. Both types of TLD were placed on the surface of the phantoms allowing assessment of visibility, entrance surface dose (ESD) and field homogeneity. In vivo assessment of ESD and visibility was also carried out on a volunteer undergoing a routine mammography examination. The positions of the GR-200F TLDs were not identified either on the image of the Leeds TOR(MAM) phantom or the patient mammograms. The average ESD for the Leeds phantom was 8.8 mGy, while the patient ESD was 13 mGy. It is now possible to perform in vivo measurements with the potential of increasing the accuracy of the doses measured for women that do not conform to a standard breast thickness or density.
引用
收藏
页码:426 / 432
页数:7
相关论文
共 50 条
  • [1] COMPARISON OF ION-CHAMBER AND TLD DOSIMETRY IN MAMMOGRAPHY
    STANTON, L
    DAY, JL
    BRATTELLI, SD
    LIGHTFOOT, DA
    VINCE, MA
    STANTON, RE
    [J]. MEDICAL PHYSICS, 1981, 8 (06) : 792 - 798
  • [2] Dosimetry in a mammography phantom using TLD-300 dosimeters
    Munoz, I. D.
    Gamboa-deBuen, I.
    Avila, O.
    Brandan, M. E.
    [J]. MEDICAL PHYSICS, 2018, 45 (09) : 4287 - 4296
  • [3] Methodology for in Vivo Dosimetry Using TLD-100 for Radiotherapic Treatment
    Teiga Rodrigues, B.
    Domingues De Souza, P.
    Daruich de Souza, C.
    Chuery Martins Rostelato, M.
    Zeituni, C.
    Ribeiro Nogueira, B.
    de Oliveira Marques, J.
    Sorgatti de Souza, A.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2898 - 2899
  • [4] Utilization of Conebeam CT to Accurately Assess TLD Placement for In-Vivo Dosimetry
    Taylor, M.
    Nautiyal, J.
    Lambert, M.
    Ku, L.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [5] FIRST RESULTS ON IN VIVO TLD DOSIMETRY IN BRACHYTHERAPY OF HEAD AND NECK CANCER PATIENTS
    Adliene, Diana
    Jakstas, Karolis
    Budzanowski, Maciej
    Rudzianskas, Viktoras
    Urbonavicius, Benas
    Inciura, Arturas
    Sniureviciute, Migle
    [J]. MEDICAL PHYSICS IN THE BALTIC STATES, 2012, : 15 - +
  • [6] TLD DOSIMETRY WITH GOOD RESOLUTION
    HECK, RJ
    FESSENDEN, P
    [J]. MEDICAL PHYSICS, 1986, 13 (04) : 610 - 610
  • [7] VERIFICATION OF AN ON LINE IN-VIVO SEMICONDUCTOR DOSIMETRY SYSTEM FOR TBI WITH 2 TLD PROCEDURES
    SANCHEZDOBLADO, F
    TERRON, JA
    SANCHEZNIETO, B
    ARRANS, R
    ERRAZQUIN, L
    BIGGS, D
    LEE, C
    NUNEZ, L
    DELGADO, A
    MUNIZ, JL
    [J]. RADIOTHERAPY AND ONCOLOGY, 1995, 34 (01) : 73 - 77
  • [8] A COMPARISON OF TLD AND FILM FOR PERSONNEL DOSIMETRY
    SUNTHARALINGAM, N
    CAMERON, JR
    [J]. HEALTH PHYSICS, 1966, 12 (11): : 1595 - +
  • [9] TLD (LIF) BETA-DOSIMETRY
    DAROIS, E
    SKRABLE, KW
    CHABOT, GE
    [J]. HEALTH PHYSICS, 1979, 37 (06): : 795 - 796
  • [10] A COMPARISON OF TLD AND FILM FOR PERSONNEL DOSIMETRY
    CAMERON, JR
    SUNTHARA.N
    [J]. HEALTH PHYSICS, 1966, 12 (12): : 1774 - +