Automatic analysis of global spinal alignment from simple annotation of vertebral bodies

被引:4
|
作者
Doerr, Sophia A. [1 ]
De Silva, Tharindu [1 ]
Vijayan, Rohan [1 ]
Han, Runze [1 ]
Uneri, Ali [1 ]
Ketcha, Michael D. [1 ]
Zhang, Xiaoxuan [1 ]
Khanna, Nishanth [2 ]
Westbroek, Erick [3 ]
Jiang, Bowen [3 ]
Zygourakis, Corinna [3 ]
Aygun, Nafi [2 ]
Theodore, Nicholas [3 ]
Siewerdsen, Jeffrey H. [1 ,2 ,3 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21205 USA
[2] Johns Hopkins Univ, Dept Radiol & Radiol Sci, Baltimore, MD 21205 USA
[3] Johns Hopkins Univ, Dept Neurosurg, Baltimore, MD 21205 USA
基金
美国国家卫生研究院;
关键词
spine surgery; global spinal alignment; image analysis; image-guided surgery; surgical outcomes; surgical data science; INTEROBSERVER RELIABILITY; SPINOPELVIC PARAMETERS; INTRAOBSERVER; DEFORMITY; RADIOGRAPHS; KYPHOSIS;
D O I
10.1117/1.JMI.7.3.035001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Measurement of global spinal alignment (GSA) is an important aspect of diagnosis and treatment evaluation for spinal deformity but is subject to a high level of inter-reader variability. Approach: Two methods for automatic GSA measurement are proposed to mitigate such variability and reduce the burden of manual measurements. Both approaches use vertebral labels in spine computed tomography (CT) as input: the first (EndSeg) segments vertebral endplates using input labels as seed points; and the second (SpNorm) computes a two-dimensional curvilinear fit to the input labels. Studies were performed to characterize the performance of EndSeg and SpNorm in comparison to manual GSA measurement by five clinicians, including measurements of proximal thoracic kyphosis, main thoracic kyphosis, and lumbar lordosis. Results: For the automatic methods, 93.8% of endplate angle estimates were within the interreader 95% confidence interval (CI95). All GSA measurements for the automatic methods were within the inter-reader CI95, and there was no statistically significant difference between automatic and manual methods. The SpNorm method appears particularly robust as it operates without segmentation. Conclusions: Such methods could improve the reproducibility and reliability of GSA measurements and are potentially suitable to applications in large datasets-e.g., for outcome assessment in surgical data science. (C) 2020 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Automatic analysis of global spinal alignment from spine CT images
    Doerr, S. A.
    De Silva, T.
    Vijayan, R.
    Han, R.
    Uneri, A.
    Ketcha, M. D.
    Zhang, X.
    Khanna, N.
    Westbroek, E.
    Jiang, B.
    Zygourakis, C.
    Aygun, N.
    Theodore, N.
    Siewerdsen, J. H.
    [J]. MEDICAL IMAGING 2019: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2019, 10951
  • [2] Does balloon kyphoplasty improve the global spinal alignment in osteoporotic vertebral fracture?
    Masahiro Kanayama
    Fumihiro Oha
    Akira Iwata
    Tomoyuki Hashimoto
    [J]. International Orthopaedics, 2015, 39 : 1137 - 1143
  • [3] Does balloon kyphoplasty improve the global spinal alignment in osteoporotic vertebral fracture?
    Kanayama, Masahiro
    Oha, Fumihiro
    Iwata, Akira
    Hashimoto, Tomoyuki
    [J]. INTERNATIONAL ORTHOPAEDICS, 2015, 39 (06) : 1137 - 1143
  • [4] Automatic annotation of dialogue structure from simple user interaction
    Purver, Matthew
    Niekrasz, John
    Ehlen, Patrick
    [J]. MACHINE LEARNING FOR MULTIMODAL INTERACTION, 2008, 4892 : 48 - 59
  • [5] Impact of spino-pelvic and global spinal alignment on the risk of osteoporotic vertebral collapse
    Ohnishi, Takashi
    Iwata, Akira
    Kanayama, Masahiro
    Oha, Fumihiro
    Hashimoto, Tomoyuki
    Iwasaki, Norimasa
    [J]. SPINE SURGERY AND RELATED RESEARCH, 2018, 2 (01):
  • [6] Fully automatic cross-modality localization and labeling of vertebral bodies and intervertebral discs in 3D spinal images
    Wimmer, Maria
    Major, David
    Novikov, Alexey A.
    Buehler, Katja
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2018, 13 (10) : 1591 - 1603
  • [7] Fully automatic cross-modality localization and labeling of vertebral bodies and intervertebral discs in 3D spinal images
    Maria Wimmer
    David Major
    Alexey A. Novikov
    Katja Bühler
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2018, 13 : 1591 - 1603
  • [8] From the Spinopelvic Parameters to Global Alignment and Proportion Scores in Adult Spinal Deformity
    Cho, Yongjae
    Jo, Dae Jean
    Hyun, Seung-Jae
    Park, Jin Hoon
    Yang, Na Rae
    [J]. NEUROSPINE, 2023, 20 (02) : 467 - 477
  • [9] Research on segmentation of vertebral bodies from spinal MR images based on gauss weighted and local contraction
    Dan, Sui
    Zhen, Jiao
    Xinfeng, Yang
    [J]. Open Cybernetics and Systemics Journal, 2015, 9 : 1064 - 1073
  • [10] Measurement of distances and locations of thoracic and lumbar vertebral bodies from CT scans in cases of spinal deformation
    Gruenwald, Alexander T. D.
    Roy, Susmita
    Lampe, Renee
    [J]. BMC MEDICAL IMAGING, 2024, 24 (01):