Matroshka DOSTEL measurements onboard the International Space Station (ISS)

被引:16
|
作者
Labrenz, Johannes [1 ]
Burmeister, Soenke [1 ]
Berger, Thomas [2 ]
Heber, Bernd [1 ]
Reitz, Guenther [2 ]
机构
[1] Univ Kiel, D-24118 Kiel, Germany
[2] German Aerosp Ctr DLR, Inst Aerosp Med, D-51147 Cologne, Germany
关键词
Galactic cosmic rays; Radiation belts; Dosimetry; International Space Station; Matroshka; SOLAR; BELT;
D O I
10.1051/swsc/2015039
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
This paper presents the absorbed dose and dose equivalent rate measurements achieved with the DOSimetry TElescope (DOSTEL) during the two Matroshka (MTR) experiment campaigns in 2004/2005 (MTR-1) and 2007/2008 (MTR-2B). The comparison between the inside (MTR-2B) and outside (MTR-1) mission has shown that the shielding thickness provided by the International Space Station (ISS) spacecraft hull has a minor effect on the radiation exposure caused by Galactic Cosmic Rays (GCR). The exposure varies with the solar modulation of the GCR, too. Particles from Earth's radiation belts are effectively shielded by the spacecraft hull, and thus the contribution to the radiation exposure is lower for the inside measurement during MTR-2B. While the MTR-DOSTEL absorbed dose rate shows a good agreement with passive detectors of the MTR experiment for the MTR-2B mission phase, the MTR-1 absorbed dose rates from MTR-DOSTEL measurements are much lower than those obtained by a nearby passive detector. Observed discrepancies between the MTR-DOSTEL measurements and the passive detectors located nearby could be explained by the additional exposure to an enhanced flux of electrons trapped between L-parameter 2.5 and 3.5 caused by solar storms in July 2004.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Experiment NORT onboard the International Space Station (ISS)
    Avanesov, GA
    Artamonov, VV
    Aust, SA
    Eremin, VV
    Zubenko, GI
    Kondabarov, AV
    Maslov, IA
    Polyakov, EV
    Ougolnikov, OS
    [J]. COSMIC RESEARCH, 2003, 41 (05) : 521 - 525
  • [2] Experiment NORT onboard the International Space Station (ISS)
    G. A. Avanesov
    V. V. Artamonov
    S. A. Aust
    V. V. Eremin
    G. I. Zubenko
    A. V. Kondabarov
    I. A. Maslov
    E. V. Polyakov
    O. S. Ougolnikov
    [J]. Cosmic Research, 2003, 41 : 521 - 525
  • [3] Radiation dosimetry onboard the International Space Station ISS
    Berger, Thomas
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2008, 18 (04): : 265 - 275
  • [4] Flight model of HISUI hyperspectral sensor onboard ISS (International Space Station)
    Tanii, Jun
    Kashimura, Osamu
    Ito, Yoshiyuki
    Iwasaki, Akira
    [J]. SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES XXI, 2017, 10423
  • [5] Flight model of HISUI hyperspectral sensor onboard ISS (International Space Station)
    Japan Space Systems, 5-8 Shibakoen 3 chome, Minato-ku, Tokyo
    105-0011, Japan
    不详
    183-8501, Japan
    不详
    153-8904, Japan
    [J]. Proc SPIE Int Soc Opt Eng, 1600,
  • [6] The ESA Active Dosimeter (EAD) system onboard the International Space Station (ISS)
    Straube, Ulrich
    Berger, Thomas
    Dieckmann, Matthias
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2024, 34 (01): : 111 - 139
  • [7] Flight model performances of HISUI hyperspectral sensor onboard ISS (International Space Station)
    Tanii, Jun
    Kashimura, Osamu
    Ito, Yoshiyuki
    Iwasaki, Akira
    [J]. SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES XX, 2016, 10000
  • [8] CURRENT STATUS OF HYPERSPECTRAL IMAGER SUITE (HISUI) ONBOARD INTERNATIONAL SPACE STATION (ISS)
    Matsunaga, Tsuneo
    Iwasaki, Akira
    Tsuchida, Satoshi
    Iwao, Koki
    Tanii, Jun
    Kashimura, Osamu
    Nakamura, Ryosuke
    Yamamoto, Hirokazu
    Kato, Soushi
    Obata, Kenta
    Mouri, Koichiro
    Tachikawa, Tetsushi
    [J]. 2017 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2017, : 443 - 446
  • [9] Early results and validation of SAGE III-ISS ozone profile measurements from onboard the International Space Station
    McCormick, M. Patrick
    Lei, Liqiao
    Hill, Michael T.
    Anderson, John
    Querel, Richard
    Steinbrecht, Wolfgang
    [J]. ATMOSPHERIC MEASUREMENT TECHNIQUES, 2020, 13 (03) : 1287 - 1297
  • [10] Depth dose measurements with the Liulin-5 experiment inside the spherical phantom of the MATROSHKA-R project onboard the International Space Station
    Semkova, J.
    Koleva, R.
    Maltchev, St.
    Bankov, N.
    Benghin, V.
    Chernykh, I.
    Shurshakov, V.
    Petrov, V.
    Drobyshev, S.
    Nikolaev, I.
    [J]. ADVANCES IN SPACE RESEARCH, 2012, 49 (03) : 471 - 478