Electromagnetic corrosion control in water cooling systems

被引:0
|
作者
de Souza, Eduardo Alencar [1 ]
da Cunha Ponciano Gomes, Jose Antonio [1 ]
机构
[1] Univ Fed Rio de Janeiro, Dept Met Engn & Mat, Rio De Janeiro, Brazil
关键词
Carbon steel; Corrosion process; Electrochemical methods; Physical treatments of water; Water cooling systems; MAGNETIC-FIELD;
D O I
10.1108/ACMM-07-2013-1279
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
Purpose - The aim was to study the effect of an electromagnetic treatment used on corrosion control of carbon steel in cooling systems. Design/methodology/approach - The aim was to assess the performance of an electromagnetic treatment used on corrosion control of carbon steel in cooling water systems. Findings - The main conclusion is that the electromagnetic system cannot induce a direct effect on the corrosion rates. The use of chemical corrosion inhibitors cannot be suggested. Social implications - The optimized industrial use of water is an objective of unquestionable importance, as water is a finite resource. The use of efficient corrosion control on water cooling systems permits the reduction of the water volume required. Consequently, a social benefit can be associated with the improvement of corrosion control technologies. Originality/value - The development of alternative corrosion control technologies, such as the use of physical treatments, has been considered as a promising tool. In this work, a consistent assessment of the results achieved on a full-scale system, without using chemical corrosion inhibitors, is presented.
引用
收藏
页码:153 / 157
页数:5
相关论文
共 50 条
  • [1] CORROSION AND FOULING CONTROL IN COOLING WATER SYSTEMS
    CHAKRABO.S
    ALLARD, B
    [J]. KEMISK TIDSKRIFT, 1974, 86 (10): : 52 - &
  • [2] CORROSION CONTROL OF INDUSTRIAL COOLING WATER-SYSTEMS
    BOFFARDI, BP
    [J]. MATERIALS PERFORMANCE, 1984, 23 (11) : 17 - 24
  • [3] Improve corrosion and deposition control in alkaline cooling water systems
    Geiger, GE
    [J]. HYDROCARBON PROCESSING, 1996, 75 (01): : 93 - 98
  • [4] Corrosion control in cooling water systems: Recent experience using a new corrosion monitor
    Hale, ER
    Yang, B
    Enzien, MV
    [J]. CORROSION IN REFINERY PETROCHEMICAL AND POWER GENERATION PLANTS, PROCEEDINGS, 2000, : 367 - 376
  • [5] Characterizing biofilms for biofouling and microbial corrosion control in cooling water systems
    George, R. P.
    Mudali, U. Kamachi
    Raj, Baldev
    [J]. ANTI-CORROSION METHODS AND MATERIALS, 2016, 63 (06) : 477 - 489
  • [6] Corrosion management in cooling water systems
    Valliappan, M
    [J]. MATERIALS PERFORMANCE, 2002, 41 (02) : 42 - 46
  • [7] Corrosion inhibitors for cooling water systems
    Wake, T.
    Horiike, M.
    [J]. Zairyo to Kankyo/ Corrosion Engineering, 2001, 50 (01): : 3 - 7
  • [8] Monitor and control cooling water corrosion
    Choudhary, SG
    [J]. HYDROCARBON PROCESSING, 2004, 83 (05): : 55 - +
  • [9] Corrosion processes and control in recirculating cooling water systems in refinery and petrochemical industry
    Taseva, V
    Dobrevsky, I
    Nenov, V
    Dimitrova, N
    Bonev, B
    Grudeva, V
    Novakova, A
    [J]. MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2000, 51 (11): : 811 - 816
  • [10] Adopting a multipurpose inhibitor to control corrosion of ferrous alloys in cooling water systems
    Mahgoub, F. M.
    Abdel-Nabey, B. A.
    El-Samadisy, Y. A.
    [J]. MATERIALS CHEMISTRY AND PHYSICS, 2010, 120 (01) : 104 - 108