Synthesis and biodegradation evaluation of nano-Si and nano-Si/TiO2 coatings on biodegradable Mg-Ca alloy in simulated body fluid

被引:30
|
作者
Bakhsheshi-Rad, H. R. [1 ]
Hamzah, E. [1 ]
Daroonparvar, M. [1 ]
Kasiri-Asgarani, M. [2 ]
Medraj, M. [3 ]
机构
[1] Univ Johor Bahru, Fac Mech Engn, Dept Mat Mfg & Ind Engn, Johor Baharu 81310, Johor, Malaysia
[2] Islamic Azad Univ, Najafabad Branch, Mat Engn Dept, Najafabad, Isfahan, Iran
[3] Concordia Univ, Dept Mech Engn, Montreal, PQ H3G 1M8, Canada
关键词
Composites; Corrosion; Mechanical properties; TiO2; Biomedical applications; AZ31 MAGNESIUM ALLOY; CORROSION BEHAVIOR; BIOMEDICAL APPLICATIONS; ELECTROPHORETIC DEPOSITION; ALUMINUM-ALLOY; HYDROXYAPATITE; NACL;
D O I
10.1016/j.ceramint.2014.05.126
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In the present study, nano-Si and nano-Si/TiO2 composite coatings have been successfully synthesized on the surface of Mg-1 wt%Ca alloy by the physical vapor deposition (PVD) method. The surface morphology and compositions of the coated specimens were characterized by X-ray diffraction (XRD), Fourier-transform infrared spectroscopy (FTIR), transmission election microscopy (TEM), scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). The results show the formation of thin and compact coating layers which homogeneously cover the surface of Mg alloy. Some micro-pores and micro-cracks were observed in the Si and Si/TiO2 films. It was also found that the Si and TiO2 nanoparticle had a spherical morphology with an average particle size of 30-40 nm and 70-80 nm, respectively. Electrochemical studies revealed that nano-Si/TiO2 coating offers a significant reduction in the corrosion rate (0.57 mm/year) compared to the Si coated (0.91 mm/year) and the uncoated alloys (6.21 nun/year) in simulated body fluid (SBF). Hydrogen evolution studies showed a lower degradation rate of nano-Si/TiO2 (1.57 mIkm(2)/day) than that of nano-Si coated alloy (2.22 ml/cm(2)/day). Immersion test showed that the nano-Si/TiO2 coating presented a greater nucleation site of hydroxyapatite (HA) than the uncoated sample. Thus nano-Si/TiO2 composite coating prepared by PVD on the Mg-Ca alloy is more appropriate for biomedical applications. (C) 2014 Elsevier Ltd and Techna Group S.r.l. All rights reserved.
引用
收藏
页码:14009 / 14018
页数:10
相关论文
共 14 条
  • [1] Synthesis, microstructure and biodegradation behavior of nano-Si and nano-ZnO/Si coatings on a Mg/HA/TiO2/MgO nanocomposite
    Khalajabadi, Shahrouz Zarnani
    Kadir, Mohammed Rafiq Abdul
    Izman, Sudin
    Samavati, Alireza
    Othaman, Zulkafli
    CERAMICS INTERNATIONAL, 2015, 41 (09) : 11346 - 11358
  • [2] Interfacial Engineering in TiO2/Nano-Si Heterostructure- Based Device Prototype for E-Nose Application
    Dwivedi, Priyanka
    Dhanekar, Saakshi
    Agrawal, Monika
    Das, Samaresh
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2018, 65 (03) : 1127 - 1131
  • [3] Effect of Si on Machinability of Al-Si-Mg Alloy and Evaluation of Tool Life with the Application of Biodegradable Esterified Nano Cutting Fluid
    Joseph, Akhil M.
    Paul, Cherian
    Aravind, Amith
    INTERNATIONAL CONFERENCE ON APPLIED MECHANICS AND OPTIMISATION (ICAMEO-2019), 2019, 2134
  • [4] Characteristics of As-Cast and Forged Biodegradable Mg-Ca Binary Alloy Immersed in Kokubo Simulated Body Fluid
    Idris, M. H.
    Jafari, H.
    Harandi, S. E.
    Mirshahi, M.
    Koleyni, S.
    MATERIALS AND MANUFACTURING TECHNOLOGIES XIV, 2012, 445 : 301 - 306
  • [5] Fabrication and corrosion behavior of Si/HA nano-composite coatings on biodegradable Mg-Zn-Mn-Ca alloy
    Bakhsheshi-Rad, H. R.
    Hamzah, E.
    Daroonparvar, M.
    Yajid, M. A. M.
    Medraj, M.
    SURFACE & COATINGS TECHNOLOGY, 2014, 258 : 1090 - 1099
  • [6] Hydroxyapatite coatings on Mg-Ca alloy prepared by Pulsed Laser Deposition: Properties and corrosion resistance in Simulated Body Fluid
    Rau, J. V.
    Antoniac, I.
    Filipescu, M.
    Cotrut, C.
    Fosca, M.
    Nistor, L. C.
    Birjega, R.
    Dinescu, M.
    CERAMICS INTERNATIONAL, 2018, 44 (14) : 16678 - 16687
  • [7] Corrosion behavior of TiO2 films on Mg-Zn alloy in simulated body fluid
    Chen, Shuai
    Guan, Shaokang
    Chen, Bin
    Li, Wen
    Wang, Jun
    Wang, Liguo
    Zhu, Shijie
    Hu, Junhua
    APPLIED SURFACE SCIENCE, 2011, 257 (09) : 4464 - 4467
  • [8] Synthesis and in vitro degradation evaluation of the nano-HA/MgF2 and DCPD/MgF2 composite coating on biodegradable Mg-Ca-Zn alloy
    Bakhsheshi-Rad, H. R.
    Idris, M. H.
    Abdul-Kadir, M. R.
    SURFACE & COATINGS TECHNOLOGY, 2013, 222 : 79 - 89
  • [9] Hierarchical Ag/TiO2/Si Forest-Like Nano/Micro-Architectures as Antireflective, Plasmonic Photocatalytic, and Self-Cleaning Coatings
    Dudem, Bhaskar
    Bharat, L. Krishna
    Leem, Jung Woo
    Kim, Dong Hyun
    Yu, Jae Su
    ACS SUSTAINABLE CHEMISTRY & ENGINEERING, 2018, 6 (02): : 1580 - 1591
  • [10] TiO2 supported Ru, Fe, and Co nano-catalysts coated in microchannel Si-microreactor for Fisher-Tropsch synthesis
    Abrokwah, Richard
    Rahman, Mahbubur
    Deshmane, Vishwanath
    Woosley, Smith
    Aravamudhan, Shyam
    Kuila, Debasish
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 251