Locally adaptive denoising of Monte Carlo dose distributions via hybrid median filtering

被引:1
|
作者
El Naqa, I [1 ]
Deasy, JO [1 ]
Vicic, M [1 ]
机构
[1] Washington Univ, Sch Med, Dept Radiat Oncol, St Louis, MO 63110 USA
关键词
D O I
10.1109/NSSMIC.2003.1352445
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A fundamental prerequisite of computer aided radiotherapy treatment is the accurate estimation of the dose distributions so as to deliver a high homogeneous dose volume to the tumor without causing unnecessary side effects for the patient, The Monte Carlo (MC) method is considered as the most effective dose distribution computational technique. However, it is too slow and contaminated with noisy degradations that could affect the dose contour visibility and the estimates of dosimetric parameters. In this work, we propose a feature-adaptive median hybrid filter for the denoising of MC dose distributions. Median filtering has been shown to outperform the moving average (mean) in removal of impulsive noise (outliers) and preservation of edges, but it fails to provide the same degree of smoothness in homogeneous regions. We combine linear filters with the median operation to produce hybrid median filters. The filter output can be obtained as a weighted sum of the linear filter and the median operation depending on the properties of the local neighborhood. We evaluated the technique on different data sets, a challenging 2-D synthetic dataset of different geometric shapes at different scales with added noise and blurring, and 2-D/3-D water phantoms. The proposed filter, judged by mean square error, performed well in comparison with currently existing techniques. Denoising of full 3-D real treatment plan datasets has shown similar promise.
引用
收藏
页码:2703 / 2706
页数:4
相关论文
共 50 条
  • [1] Denoising of Monte Carlo dose distributions via locally adaptive hybrid median filtering
    El Naqa, I
    Deasy, J
    Vicic, M
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1452 - 1452
  • [2] Denoising of Monte Carlo dose distributions
    Deasy, JO
    [J]. PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 1494 - 1496
  • [3] Adaptive anisotropic diffusion filtering of Monte Carlo dose distributions
    Miao, BH
    Jeraj, R
    Bao, SL
    Mackie, TR
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (17): : 2767 - 2781
  • [4] Denoising of electron beam Monte Carlo dose distributions using digital filtering techniques
    Deasy, JO
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (07): : 1765 - 1779
  • [5] Denoising of Monte Carlo Dose Distributions Using UNet
    Javaid, U.
    Souris, K.
    Dasnoy, D.
    Montero, A. Barragan
    Huang, S.
    Lee, J.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E120 - E120
  • [6] Hybrid of median filtering and average filtering for Monte Carlo global illumination
    Xu, Q
    Sun, JZ
    Cai, J
    Shu, YT
    [J]. CAD/GRAPHICS '2001: PROCEEDINGS OF THE SEVENTH INTERNATIONAL CONFERENCE ON COMPUTER AIDED DESIGN AND COMPUTER GRAPHICS, VOLS 1 AND 2, 2001, : 838 - 841
  • [7] The denoising of Monte Carlo dose distributions using convolution superposition calculations
    El Naqa, I.
    Cui, J.
    Lindsay, P.
    Olivera, G.
    Deasy, J. O.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (17): : N375 - N385
  • [8] Using convolution superposition to guide denoising of Monte-Carlo dose distributions
    El Naqa, I.
    Cui, J.
    Olivera, G.
    Deasy, J.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2200 - 2200
  • [9] Denoising of electron beam Monte Carlo dose distributions using digital filtering techniques (vol 45, pg 1765, 2000)
    Deasy, JO
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (08): : 2441 - 2441
  • [10] Monte Carlo dose distributions for radiosurgery
    Perucha, M
    Sánchez-Doblado, F
    Leal, A
    Rincón, M
    Núnez, L
    Arráns, R
    Carrasco, E
    Sánchez-Nieto, B
    Sánchez-Calzado, JA
    Errazquin, L
    [J]. ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 561 - 564