Heart rate detection with accelerometric sensors under the mattress

被引:0
|
作者
Conti, Massimo [1 ]
Aironi, Carlo [1 ]
Orcioni, Simone [1 ]
Seepold, Ralf [2 ,3 ]
Gaiduk, Maksym [4 ,5 ]
Madrid, Natividad Martinez [3 ,6 ]
机构
[1] Univ Politecn Marche, Dip Ingn Informaz, Ancona, Italy
[2] HTWG Konstanz, Dept Comp Sci, Constance, Germany
[3] IM Sechenov First Moscow State Med Univ, Inst Digital Med, Moscow, Russia
[4] HTWG Konstanz, Ubiquitous Comp Lab, Constance, Germany
[5] Univ Seville, ETSII, Seville, Spain
[6] Reutlingen Univ, Sch Informat, Reutlingen, Germany
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The ballistocardiography is a technique that measures the heart rate from the mechanical vibrations of the body due to the heart movement. In this work a novel non-invasive device placed under the mattress of a bed estimates the heart rate using the ballistocardiography. Different algorithms for heart rate estimation have been developed.
引用
收藏
页码:4063 / 4066
页数:4
相关论文
共 50 条
  • [1] Continuous Monitoring of Heart Rate Using Accelerometric Sensors
    Studnicka, Filip
    Seba, Petr
    Jezbera, Daniel
    Kriz, Jan
    [J]. 2012 35TH INTERNATIONAL CONFERENCE ON TELECOMMUNICATIONS AND SIGNAL PROCESSING (TSP), 2012, : 559 - 561
  • [2] Motion Assessment for Accelerometric and Heart Rate Cycling Data Analysis
    Charvatova, Hana
    Prochazka, Ales
    Vysata, Oldrich
    [J]. SENSORS, 2020, 20 (05)
  • [3] REAL-WORLD STUDY OF HEART RATE VARIABILITY DURING SLEEP USING UNDER-MATTRESS SENSORS IN OVER 30,000 INDIVIDUALS
    Leng, Yue
    Cotton-Clay, Andrew
    Baron, Susan
    Fava, Laura
    Johnson, Kyle
    Easwar, Venkat
    Kinsolving, Arthur
    Kahn, Philippe
    Zitser, Jennifer
    Kushida, Clete
    [J]. SLEEP, 2024, 47 : A208 - A208
  • [4] Bayesian Fusion of Multiple Sensors for Reliable Heart Rate Detection
    Borges, Gabriel de Morais
    Brusamarello, Valner
    [J]. 2014 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC) PROCEEDINGS, 2014, : 1310 - 1313
  • [5] Stress Detection Using Low Cost Heart Rate Sensors
    Salai, Mario
    Vassanyi, Istvan
    Kosa, Istvan
    [J]. JOURNAL OF HEALTHCARE ENGINEERING, 2016, 2016
  • [6] Contactless and continuous monitoring of heart rate based on photoplethysmography on a mattress
    Wong, M. Y. M.
    Pickwell-MacPherson, E.
    Zhang, Y. T.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2010, 31 (07) : 1065 - 1074
  • [7] Heart rate variability evaluation of sleep mattress breathing categories
    Tenhunen, M.
    Lipponen, J.
    Virkkala, J.
    Kuusimaki, S.
    Himanen, S. -L.
    [J]. JOURNAL OF SLEEP RESEARCH, 2014, 23 : 166 - 166
  • [8] Wearable sensors for smart abnormal heart rate detection during skiing
    Yue, Nan
    Claes, Stephan
    [J]. INTERNET TECHNOLOGY LETTERS, 2021, 4 (03)
  • [9] Comparative Study of Heart Rate Extraction Methods for a Novel Intelligent Mattress
    Otis, Samuel
    Mezghani, Neila
    Abdulrazak, Bessam
    [J]. 9TH INTERNATIONAL SYMPOSIUM ON SIGNAL, IMAGE, VIDEO AND COMMUNICATIONS (ISIVC 2018), 2018, : 93 - 98
  • [10] Estimating heart rate and RSA from the mattress-recorded kinetocardiogram
    Woodward, Steven H.
    Arsenault, Ned J.
    Voelker, Karin
    Nguyen, Tram
    Lynch, Janel
    Leskin, Greg
    Sheikh, Javaid
    [J]. PSYCHOPHYSIOLOGY, 2007, 44 (04) : 635 - 638