Asymmetric MRI magnet design using a hybrid numerical method

被引:36
|
作者
Zhao, HW [1 ]
Crozier, S [1 ]
Doddrell, DM [1 ]
机构
[1] Univ Queensland, Ctr Magnet Resonance, Brisbane, Qld 4072, Australia
关键词
MRI magnet; asymmetric design; hybrid numerical method;
D O I
10.1006/jmre.1999.1924
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper describes a hybrid numerical method for the design of asymmetric magnetic resonance imaging magnet systems. The problem is formulated as a field synthesis and the desired current density on the surface of a cylinder is first calculated by solving a Fredholm equation of the first kind. Nonlinear optimization methods are then invoked to fit practical magnet coils to the desired current density. The field calculations are performed using a semi-analytical method. A new type of asymmetric magnet is proposed in this work. The asymmetric MRI magnet allows the diameter spherical imaging volume to be positioned close to one end of the magnet. The main advantages of making the magnet asymmetric include the potential to reduce the perception of claustrophobia for the patient, better access to the patient by attending physicians, and the potential for reduced peripheral nerve stimulation due to the gradient coil configuration. The results highlight that the method can be used to obtain an asymmetric MRI magnet structure and a very homogeneous magnetic field over the central imaging volume in clinical systems of approximately 1.2 m in length. Unshielded designs are the focus of this work. This method is flexible and may be applied to magnets of other geometries. (C) 1999 Academic Press.
引用
收藏
页码:340 / 346
页数:7
相关论文
共 50 条
  • [1] Minimum Volume Optimal Design Method of Hybrid MRI Magnet
    Liu, Quanyue
    Lee, Sangjin
    Choi, Kibum
    Hahn, Seungyong
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2021, 31 (05)
  • [2] A comparison of MRI magnet design using a Hopfield Network and the Optimized Material Distribution method
    Lowther, DA
    Mai, W
    Dyck, DN
    IEEE TRANSACTIONS ON MAGNETICS, 1998, 34 (05) : 2885 - 2888
  • [3] Asymmetric Gradient Coil Design by Numerical Approach for MRI Brain Imaging
    You, Xiao Fei
    Yang, Wen Hui
    Song, Tao
    Wang, Hui Xian
    Wang, Zheng
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2012, 22 (03)
  • [4] Electromagnetic design of MRI superconducting magnet based on novel hybrid optimization methods
    Mei, Yunhao
    Liu, Qingyun
    Du, Huiyu
    Zhou, Yufu
    Liu, Zhengrong
    Mo, Lei
    Qiu, Bensheng
    Zhang, Qing
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2024, 617
  • [5] Iterative EM design of an MRI magnet using HTS materials
    Xu, Minfeng
    Ogle, Michele
    Huang, Xianrui
    Amm, Kathleen
    Laskaris, Evangelos T.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2007, 17 (02) : 2192 - 2195
  • [6] Optimization Design of Surface Permanent Magnet Synchronous Motor with Hybrid Magnets using Analytical Method
    Diao, Chengwu
    Zhao, Wenliang
    Li, Longxuan
    Kwon, Byung-il
    2024 IEEE 21ST BIENNIAL CONFERENCE ON ELECTROMAGNETIC FIELD COMPUTATION, CEFC 2024, 2024,
  • [7] A new design method for completely open architecture permanent magnet for MRI
    Yao, YY
    Fang, YT
    Koh, CS
    Ni, GZ
    IEEE TRANSACTIONS ON MAGNETICS, 2005, 41 (05) : 1504 - 1507
  • [8] A novel optimal design method of passive shimming for permanent MRI magnet
    Zhang, Yanli
    Xie, Dexin
    Bai, Baodong
    Yoon, Hee Sung
    Koh, Chang Seop
    IEEE TRANSACTIONS ON MAGNETICS, 2008, 44 (06) : 1058 - 1061
  • [9] Globally Optimal Superconducting Homogeneous Magnet Design for an Asymmetric 3.0 T Head MRI Scanner
    Ni, Zhipeng
    Hu, Geli
    Wang, Qiuliang
    Yan, Luguang
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2014, 24 (03)
  • [10] A homogeneous superconducting magnet design using a hybrid optimization algorithm
    Ni, Zhipeng
    Wang, Qiuliang
    Liu, Feng
    Yan, Luguang
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2013, 24 (12)