Development of PD on-line monitoring system for large turbine generators

被引:1
|
作者
Huang, CJ [1 ]
Yu, WY [1 ]
Wei, W [1 ]
机构
[1] Shanghai Jiao Tong Univ, Power Sch, Shanghai 200030, Peoples R China
关键词
D O I
10.1109/ELINSL.2002.995872
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The feature of partial discharge (PD) is an important aspect of generators' insulation. The paper introduces an automatic on-line PD monitoring system for large turbine generators. By using digital signal processor (DSP) sampling technology, the system can get long duration PD signal with high sampling rate. Fast Fourier Transform (FFT) analysis, Finite Impulse Response (FIR) filter, Adaptive filter and Wavelet analysis have been used in data processing. DSP, high performance industry computer and multi-CPU server provide powerful ability for data processing. Client/Server structure and Fiber Distributed Data Interface (FDDI) network have been used in the system, so it can be expand to the distributing monitoring system for monitoring several generators in the same power plant simultaneously. Information of PD pulse can be kept in the database in server permanently; it can be used to follow the track of large generators aging. The system can recognize several typical PD in large turbine generator. Results from large turbine generators are given at the end of the paper.
引用
收藏
页码:23 / 26
页数:4
相关论文
共 50 条
  • [1] Study on an expert monitoring system used for PD on-line monitoring of large turbine generators
    Wu, GN
    Xu, DG
    Jiang, XW
    Xie, HK
    Park, DH
    [J]. 1998 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS, PROCEEDINGS, 1998, : 819 - 822
  • [2] An adaptive digital filter system used for on-line monitoring of PD in large turbine generator
    Wu, GN
    Huang, ZG
    Xie, HK
    Ma, JX
    Chen, ZP
    Chen, ZQ
    Sun, DL
    [J]. JOINT CONFERENCE OF 96' AICDEI / 4T-JCCEID, 1996, : 357 - 360
  • [3] Development of on-line vibration condition monitoring system of hydro generators
    Wang, Y
    Sun, FX
    Huang, TS
    [J]. PROCEEDINGS OF THE 2004 INTERNATIONAL CONFERENCE ON MACHINE LEARNING AND CYBERNETICS, VOLS 1-7, 2004, : 1025 - 1029
  • [4] Noise rejection techniques used for on-line monitoring of partial discharges in large turbine generators
    Jiang, XW
    Zhang, XH
    Jia, ZD
    Xie, HK
    [J]. PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 & 2, 2000, : 157 - 160
  • [5] Development of the on-line monitoring system of partial discharge in large generators based on virtual instruments technology
    Yue, B
    Zhang, BH
    Chen, XL
    Cao, XP
    Xie, HK
    [J]. PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 266 - 269
  • [6] Research on on-line PD monitoring system for large power transformer
    Ma, WP
    Hao, DZ
    Zheng, LH
    Wang, S
    [J]. 1998 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS, PROCEEDINGS, 1998, : 505 - 508
  • [7] The study on on-line monitoring of fault discharge in large generators
    Xie, HK
    Jiang, XW
    [J]. 1998 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS, PROCEEDINGS, 1998, : 491 - 496
  • [8] Design of on-line monitoring system of turbine cavitation
    Pu, Zhongqi
    Zhang, Wei
    Shi, Keren
    Wu, Yulin
    [J]. Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2004, 28 (21): : 62 - 64
  • [9] Research of on-line monitoring system of turbine cavitation
    Pu, ZQ
    Zhang, W
    Shi, KR
    Wu, YL
    [J]. PROCEEDINGS OF THE THIRD INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, VOL 1, 2004, : 1154 - 1158
  • [10] On-line heat rate monitoring as a basis for an on-line turbine diagnostic system
    Bercovich, Y.
    Glickman, S.
    Levin, L.
    Gordinsky, A.
    Belfor, V.
    Berman, M.
    [J]. Proceedings of the ASME Power Conference 2005, Pts A and B, 2005, : 325 - 331