Parameter optimization for operation of a bed-based task/ambient air conditioning (TAC) system to achieve a thermally neutral environment with minimum energy use

被引:16
|
作者
Mao, Ning [1 ,2 ]
Pan, Dongmei [3 ]
Chan, Mingyin [2 ]
Deng, Shiming [2 ]
机构
[1] China Univ Petr East China, Coll Pipeline & Civil Engn, Qingdao, Shandong, Peoples R China
[2] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
[3] South China Univ Technol, Sch Mech & Automot Engn, Guangzhou, Guangdong, Peoples R China
关键词
Bed-based task; ambient air conditioning system; Optimum operating parameters; Thermally neutral sleeping environment; Energy use; Computational fluid dynamics; Design of experiment; HEAT-TRANSFER; PERFORMANCE EVALUATION; SLEEPING ENVIRONMENTS; COMFORT; CFD; VERIFICATION; VENTILATION; SUBTROPICS; MODELS; FLOW;
D O I
10.1177/1420326X15608678
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The purpose of this paper is to optimize the operating parameters such as: supply air temperature, supply air flow rate and supply air humidity, for a bed-based task/ambient air conditioning (TAC) system installed in an experimental bedroom with two total insulation values of beddings and bed to obtain a thermally neutral sleeping environment with minimum energy use. A computational fluid dynamics (CFD) method was applied to calculate the values of predicted mean vote (PMV) and energy utilization coefficient (EUC) based on conditions of 16 simulation cases. From the simulation results, the design of experiment method was applied to identify operating parameters, individually or combined, that could significantly affect thermal neutrality and energy use for the bedroom environment to establish linear regression models for PMV and EUC. These models were used to obtain the optimum operating parameters of the bed-based TAC system. These models were validated by comparing the obtained optimization results using the models with the predicted results given by the CFD method. The results suggested that for a bed-based TAC system at a specified total insulation value of beddings and bed, a lower energy use can be achieved through adjusting operating parameters while the thermal comfort is maintained.
引用
收藏
页码:132 / 144
页数:13
相关论文
共 11 条
  • [1] Optimization on the performances of a novel bed-based task/ambient conditioning (TAC) system
    Pan Dongmei
    Deng Shiming
    Chan Mingyin
    [J]. ENERGY AND BUILDINGS, 2017, 144 : 181 - 190
  • [2] Performance evaluation of a novel bed-based task/ambient conditioning (TAC) system
    Pan Dongmei
    Chan Mingyin
    Xia Liang
    Xu Xiangguo
    Deng Shiming
    [J]. ENERGY AND BUILDINGS, 2012, 44 : 54 - 62
  • [3] Thermal, ventilation and energy saving performance evaluations of a ductless bed-based task/ambient air conditioning (TAC) system
    Mao Ning
    Pan Dongmei
    Deng Shiming
    Chan Mingyin
    [J]. ENERGY AND BUILDINGS, 2013, 66 : 297 - 305
  • [4] Experimental and numerical studies on the performance evaluation of a bed-based task/ambient air conditioning (TAC) system
    Ning, Mao
    Dongmei, Pan
    Mingyin, Chan
    Shiming, Deng
    [J]. APPLIED ENERGY, 2014, 136 : 956 - 967
  • [5] The Development of the Bed-Based Task/Ambient Air Conditioning System Applied to Sleeping Environments
    Deng Shiming
    Du Jing
    [J]. CLEANER ENERGY FOR CLEANER CITIES, 2018, 152 : 330 - 335
  • [6] A numerical study on influences of building envelope heat gain on operating performances of a bed-based task/ambient air conditioning (TAC) system in energy saving and thermal comfort
    Mao Ning
    Pan Dongmei
    Li Zhao
    Xu Yingjie
    Song Mengjie
    Deng Shiming
    [J]. APPLIED ENERGY, 2017, 192 : 213 - 221
  • [7] Energy performance of a bedroom task/ambient air conditioning (TAC) system applied in different climate zones of China
    Mao, Ning
    Hao, Jingyu
    Cui, Borui
    Li, Yuxing
    Song, Mengjie
    Xu, Yingjie
    Deng, Shiming
    [J]. ENERGY, 2018, 159 : 724 - 736
  • [8] Working parameter selection and analysis of radiant floor cooling combined with desk-based task/ambient conditioning (TAC) system
    Sun Liying
    Tan Shuang
    Zhen Lujie
    [J]. BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2017, 38 (01): : 104 - 120
  • [9] PMV-based dynamic optimization of energy consumption for a residential task/ambient air conditioning system in different climate zones
    Mao, Ning
    Hao, Jingyu
    He, Tianbiao
    Song, Mengjie
    Xu, Yingjie
    Deng, Shiming
    [J]. RENEWABLE ENERGY, 2019, 142 : 41 - 54
  • [10] Energy-saving Optimization Operation of Central Air-conditioning System Based on Double-DQN Algorithm
    Yan, Junwei
    Huang, Qi
    Zhou, Xuan
    [J]. Huanan Ligong Daxue Xuebao/Journal of South China University of Technology (Natural Science), 2019, 47 (01): : 135 - 144