Full-scale experiment on smoke propagation in metro station tunnel fire under opening the platform screen doors

被引:18
|
作者
Qiu, Peiyun [1 ,2 ,3 ]
Long, Zeng [1 ]
Liu, Chang [1 ]
Yang, Yuxuan [1 ]
Tian, Xiangliang [1 ]
Zhong, Maohua [1 ]
机构
[1] Tsinghua Univ, Dept Engn Phys, Inst Publ Safety Res, Beijing 100084, Peoples R China
[2] Beijing Key Lab City Integrated Emergency Respons, Beijing 100084, Peoples R China
[3] Guangzhou Metro Grp Co LTD, Guangzhou 510330, Guangdong, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
Full-scale experiment; Fire; Smoke propagation; Station tunnel; Platform screen doors;
D O I
10.1016/j.tust.2020.103662
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The study conducted full-scale fire experiments in a representative subway station tunnel to investigate the law of smoke propagation, and three typical ventilation conditions were designed. Under opening the platform screen doors (PSD), the fuel pan was placed at the centerline of the tunnel, and the temperature profile was measured by a series of thermocouples. The vertical temperature distribution, longitudinal temperature distribution and smoke layer height were analyzed based on the measured data in the field. The results showed that the fire-induced smoke propagation was affected significantly by the longitudinal airflow. Under the natural ventilation, the temperature near the fire region was relatively low, and the smoke layer height varied slightly with the distance. Under the mechanical ventilation, the over track exhaust (OTE) system was activated by default, and the mode of the tunnel ventilation fan (TVF) system was changed. When the TVF system in the mode of supply in the A-end and exhaust in the B-end, the smoke distributed within the range of X = 38.5 to 5.5 m. At the location of X = 38.5 m, the smoke layer height was approximately 2 m, which had an impact on the evacuation. When the TVF system in the mode of exhaust at both ends, the smoke gathered at both ends of tunnel, with the smoke layer height of 4.7 m. Therefore, the third ventilation condition performed better owing to its more stable smoke layer and lower temperature. The conclusions from the full-scale fire experiments could provide on-site data for the emergency response during fire accident in metro station tunnels.
引用
下载
收藏
页数:8
相关论文
共 32 条
  • [1] Study on smoke propagation in tunnel construction of a hydropower station: A full-scale fire experiment
    Liu, Chang
    Cheng, Huihang
    Nie, Wenjun
    Jiang, Senlin
    Chen, Junfeng
    Lin, Peng
    Zhong, Maohua
    JOURNAL OF SAFETY SCIENCE AND RESILIENCE, 2023, 4 (02): : 188 - 202
  • [2] Full-scale experiment and CFD simulation on smoke movement and smoke control in a metro tunnel with one opening portal
    Weng, Miao Cheng
    Yu, Long Xing
    Liu, Fang
    Nielsen, Peter V.
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2014, 42 : 96 - 104
  • [3] Fire Ventilation in platform screen doors equipped Metro Station
    Faggioni, Nicolo
    Giauni, Francesca
    Bringiotti, Massimiliano
    GALLERIE E GRANDI OPERE SOTTERRANEE, 2018, (128): : 29 - 35
  • [4] Numerical and theoretical evaluations of the propagation of smoke and fire in a full-scale tunnel
    Wang, H. Y.
    FIRE SAFETY JOURNAL, 2012, 49 : 10 - 21
  • [5] The impact of screen doors on smoke spread of tunnel fire in island subway platform
    School of Municipal and Environmental Engineering, Shenyang Jianzhu University, Shenyang 110168, China
    Shenyang Jianzhu Daxe Xuebao, 2007, 5 (794-797):
  • [6] Full-scale experimental study on the smoke characteristics of train fire stopping at rescue station in railway tunnel
    Chen L.F.
    Hu L.H.
    Wang Q.S.
    Liu B.H.
    Meng N.
    Wu L.B.
    Wang H.B.
    Liu S.
    Wu L.
    Wang W.W.
    Journal of Applied Fire Science, 2010, 20 (03): : 251 - 270
  • [7] Full-scale fire tests of RC metro shield TBM tunnel linings
    Yan, Zhi-guo
    Zhu, He-hua
    Ju, J. Woody
    Ding, Wen-qi
    CONSTRUCTION AND BUILDING MATERIALS, 2012, 36 : 484 - 494
  • [8] Full-scale experimental study on fire-induced smoke propagation in large underground plant of hydropower station
    Liu, Chang
    Tian, Xiangliang
    Zhong, Maohua
    Lin, Peng
    Gong, Yuanping
    Yin, Bin
    Wang, Hongbin
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2020, 103
  • [9] Full-scale immersed tunnel fire experimental research on smoke flow patterns
    Xu, P.
    Jiang, S. P.
    Xing, R. J.
    Tan, J. Q.
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2018, 81 : 494 - 505
  • [10] Study on the smoke propagation characteristics of metro tunnel fire under the effects of piston wind
    Wang, Fei
    Liu, Fang
    Obadi, Imad
    Weng, Miaocheng
    INDOOR AND BUILT ENVIRONMENT, 2023, 32 (01) : 149 - 169