Cyclic variation in ultrasonic myocardial integrated backscatter is due to phasic changes in the number of patent myocardial microvessels

被引:11
|
作者
Micari, Antonio [1 ]
Pascotto, Marco [1 ]
Jayaweera, Ananda R. [1 ]
Sklenar, Jiri [1 ]
Goodman, Craig [1 ]
Kaul, Sanjiv [1 ]
机构
[1] Oregon Hlth & Sci Univ, Div Cardiovasc Med, Portland, OR 97239 USA
关键词
cardiac contraction; cyclic variation; integrated backscatter; myocardial blood volume;
D O I
10.7863/jum.2006.25.8.1009
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective. We tested the hypothesis that the cyclic variation in ultrasonic myocardial integrated backscatter (IBS) is due to cardiac contraction-induced changes in the number of patent myocardial microvessels. Methods. We performed experiments in open-chest dogs in which we increased the number of patent myocardial microvessels without changing cardiac contraction. We achieved this either by direct intracoronary administration of adenosine (group 1; n = 10) or by producing a noncritical coronary stenosis (group 2; n = 7). Results. At baseline, IBS was lowest in systole and highest in diastole. This cyclic variation in IBS was closely associated with the phasic changes in myocardial blood volume that were measured with myocardial contrast echocardiography. During adenosine administration, the diastolic IBS increased from -18.8 +/- 6.5 to -17.5 +/- 6.1 dB (P = .002), with an associated increase in the difference between the systolic and diastolic IBS from 3.8 +/- 1.1 to 4.6 +/- 1.0 dB (P = .009). After a noncritical stenosis was produced, diastolic IBS also increased from -26.6 +/- 8.3 to -25.2 +/- 7.3 dB (P = .001), with an associated increase in the difference between the systolic and diastolic IBS from 3.7 +/- 1.2 to 5.0 +/- 1.0 dB (P = .02). No change in IBS was noted in the bed that did not receive adenosine or the bed that had a stenosis. Conclusions. The variation in IBS during the cardiac cycle is closely associated with the phasic changes in myocardial blood volume seen during cardiac contraction. When the number of patent myocardial arterioles is increased via adenosine or placement of a noncritical stenosis, diastolic IBS increases with a concomitant increase in IBS cyclic variation. These results may have important clinical applications for the noninvasive diagnosis of noncritical coronary stenosis at rest.
引用
收藏
页码:1009 / 1019
页数:11
相关论文
共 50 条
  • [1] Influence of Contractility on Myocardial Ultrasonic Integrated Backscatter and Cyclic Variation in Integrated Backscatter
    毕小军
    邓又斌
    潘敏
    杨好意
    向慧娟
    常青
    黎春雷
    Current Medical Science, 2002, (03) : 233 - 234
  • [2] Influence of contractility on myocardial ultrasonic integrated backscatter and cyclic variation in integrated backscatter
    Bi Xiaojun
    Deng Youbin
    Pan Min
    Yang Haoyi
    Xiang Huijuan
    Chang Qing
    Li Chunlei
    Current Medical Science, 2002, 22 (3) : 233 - 234
  • [3] REDUCED CYCLIC VARIATION OF ULTRASONIC INTEGRATED BACKSCATTER DURING MYOCARDIAL CONTRAST
    MELTZER, RS
    OHAD, DG
    REISNER, SA
    SUCHER, E
    KAPLINSKY, E
    MOTRO, M
    BATTLER, A
    VERED, Z
    CIRCULATION, 1993, 88 (04) : 163 - 163
  • [4] Cyclic variation of myocardial integrated backscatter ultrasonic signal in hypertensive cardiomyopathy
    Di Bello, V
    Pedrinelli, R
    Bertini, A
    Giorgi, D
    Talini, E
    Cioppi, A
    Dell'Omo, G
    Moretti, L
    Giusti, C
    EUROPEAN HEART JOURNAL, 2000, 21 : 619 - 619
  • [5] CYCLIC VARIATION OF MYOCARDIAL BACKSCATTER - AN ULTRASONIC INDEX OF CONTRACTILE FUNCTION
    GLUECK, RM
    MOTTLEY, JG
    MILLER, JG
    SOBEL, BE
    PEREZ, JE
    CIRCULATION, 1983, 68 (04) : 330 - 330
  • [6] Ultrasonic analysis of anthracycline-induced myocardial damage using cyclic variation of integrated backscatter
    Nagai, H
    Omi, W
    Yuasa, T
    Sakagami, S
    Takata, S
    Kobayashi, K
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2003, 16 (08) : 808 - 813
  • [7] CYCLIC VARIATION OF INTEGRATED BACKSCATTER OF THE MYOCARDIUM PARALLELS MYOCARDIAL THICKENING
    LEUNG, DY
    GRIMM, RA
    MOREHEAD, A
    RODRIGUEZ, LL
    GRIFFIN, BP
    CIRCULATION, 1994, 90 (04) : 608 - 608
  • [8] DETECTION OF MYOCARDIAL EDEMA DUE TO HEMODILUTION USING INTEGRATED ULTRASONIC BACKSCATTER
    HAASLER, GB
    SAGAR, KB
    RHYNE, TL
    BOERBOOM, L
    OLINGER, GN
    WANN, LS
    CLINICAL RESEARCH, 1986, 34 (04): : A894 - A894
  • [9] Cyclic variation of myocardial integrated backscatter and myocardial wall thickness during percutaneous coronary angioplasty
    Tekten, T
    Onbasili, AO
    Ceyhan, C
    Discigil, B
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2003, 20 (05): : 423 - 428
  • [10] Novel ultrasonic fusion imaging method based on cyclic variation in myocardial backscatter
    J. Bai
    Y. Jiang
    X. Li
    D. Pan
    G. Hu
    P. He
    Medical and Biological Engineering and Computing, 2002, 40 : 163 - 167