Ultrasensitive Controlled Release Aptasensor Using Thymine-Hg2+- Thymine Mismatch as a Molecular Switch for Hg2+ Detection

被引:62
|
作者
Ma, Ning [1 ]
Ren, Xiang [1 ]
Wang, Huan [1 ]
Kuang, Xuan [1 ]
Fan, Dawei [1 ]
Wu, Dan [1 ]
Wei, Qin [1 ]
机构
[1] Univ Jinan, Collaborat Innovat Ctr Green Chem Mfg & Accurate, Sch Chem & Chem Engn, Jinan 250022, Peoples R China
基金
中国国家自然科学基金;
关键词
MESOPOROUS SILICA NANOCONTAINERS; SENSITIVE DETECTION; GOLD NANOPARTICLES; BASE-PAIRS; MERCURY; APTAMER; BIOSENSOR; SENSOR; WATER; GRAPHENE;
D O I
10.1021/acs.analchem.0c03110
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An ultrasensitive controlled release system electrochemical aptasensor (CRSEA) has been developed for supersensitive determination of mercury ions (Hg2+), using gold nanoparticle-linked specific single-stranded DNA (Au NPs-ssDNA) as a molecular gate and mesoporous silica nanocontainers (MSNs) as containers. MSNs have a rich porous structure, thus entrapping the toluidine blue (TB) molecules inside. It is worth noting that Hg2+ binds to the ssDNA with multiple thymine (T) and induces the ssDNA to form a hairpin structure, which makes the separation of the Au NPs-ssDNA from the MSNs. Eventually, the stored TB molecules were released from MSNs. The electron transfer signals of TB were detected stably by a differential pulse voltammetry (DPV) detection method, which are correlated with the concentration of Hg2+. Therefore, the wide linear range (10 pM-100 mu M) and low limit of detection (2.9 pM) were obtained, and the system also displayed an apparent electrochemical signal response in real sample detection and showed a promising possibility in actual monitoring.
引用
收藏
页码:14069 / 14075
页数:7
相关论文
共 50 条
  • [1] Practical and regenerable electrochemical aptasensor based on nanoporous gold and thymine-Hg2+-thymine base pairs for Hg2+ detection
    Zeng, Guangming
    Zhang, Chen
    Huang, Danlian
    Lai, Cui
    Tang, Lin
    Zhou, Yaoyu
    Xu, Piao
    Wang, Hou
    Qin, Lei
    Cheng, Min
    BIOSENSORS & BIOELECTRONICS, 2017, 90 : 542 - 548
  • [2] Electrochemical aptasensor based on Au@HS-rGO and thymine-Hg2+- thymine structure for sensitive detection of mercury ion
    Zhao, Lei
    Wang, Yaoguang
    Zhao, Guanhui
    Zhang, Nuo
    Zhang, Yong
    Luo, Xiliang
    Du, Bin
    Wei, Qin
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 848
  • [3] A ratiometric electrochemical biosensor for sensitive detection of Hg2+ based on thymine-Hg2+-thymine structure
    Xiong, Erhu
    Wu, Liang
    Zhou, Jiawan
    Yu, Peng
    Zhang, Xiaohua
    Chen, Jinhua
    ANALYTICA CHIMICA ACTA, 2015, 853 : 242 - 248
  • [4] Thymine-Hg2+-Thymine Structure-based Detection of Hg2+ Enhanced by Gold Nanoparticle
    Mo Zhi-Hong
    Yang Lin-Ling
    Yang Xiao-Chao
    Chen Zi-Feng
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 37 (07) : 1033 - 1036
  • [5] Electrochemical Aptasensor Based on Sulfur Nitrogen Codoped Ordered Mesoporous Carbon and Thymine-Hg2+-Thynnine Mismatch Structure for Hg2+ Detection
    Lai, Cui
    Liu, Shiyu
    Zhang, Chen
    Zeng, Guangming
    Huang, Danlian
    Qin, Lei
    Liu, Xigui
    Yi, Huan
    Wang, Rongzhong
    Huang, Fanglong
    Li, Bisheng
    Hu, Tianyu
    ACS SENSORS, 2018, 3 (12): : 2566 - 2573
  • [6] Highly sensitive surface acoustic wave biosensor for the detection of Hg2+ based on the thymine-Hg2+-thymine structure
    Sun, Huimin
    Yang, Chunzhen
    Wang, Hong
    ANALYTICAL METHODS, 2023, 15 (36) : 4728 - 4735
  • [7] Ultrasensitive electrochemical sensing of Hg2+ based on thymine-Hg2+-thymine interaction and signal amplification of alkaline phosphatase catalyzed silver deposition
    Xu, Aigui
    Chao, Long
    Xiao, Hongbo
    Sui, Yuyun
    Liu, Jia
    Xie, Qingji
    Yao, Shouzhuo
    BIOSENSORS & BIOELECTRONICS, 2018, 104 : 95 - 101
  • [8] Intense charge transfer surface based on graphene and thymine-Hg (II)-thymine base pairs for detection of Hg2+
    Li, Jiao
    Lu, Liping
    Kang, Tianfang
    Cheng, Shuiyuan
    BIOSENSORS & BIOELECTRONICS, 2016, 77 : 740 - 745
  • [9] Label-Free Resonance Light Scattering Detection of Hg2+ Based on Specific Structure Thymine- Hg2+-Thymine
    Yang Sheng-yuan
    Xu Xiao-na
    Yu Jun-hui
    Yang Hui-xian
    Hu Cheng-lan
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35 (12) : 3471 - 3474
  • [10] Method for detection of Hg2+ based on the specific thymine-Hg2+-thymine interaction in the DNA hybridization on the surface of quartz crystal microbalance
    Sheng, Zhonghan
    Han, Jianhua
    Zhang, Jianping
    Zhao, Hong
    Jiang, Long
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2011, 87 (02) : 289 - 292