Picosecond dissector with crossed sweep and optimization of picosecond dissector parameters.

被引:0
|
作者
Andreev, S. [2 ]
Dorokhov, V. [1 ]
Getmanov, Ya. [1 ,3 ]
Komelkov, A. [1 ]
Malyutin, D. [4 ]
Matveenko, A. [4 ]
Meshkov, O. [1 ,3 ]
Ries, M. [4 ]
Smirnov, A. [2 ]
Vorobiev, N. [2 ]
Zarovsky, A. [2 ]
Kurkin, G. [1 ]
机构
[1] RAS, SB, BINP, Novosibirsk, Russia
[2] RAS, GPI, Prokhorov Gen Phys Inst, Novosibirsk, Russia
[3] Novosibirsk State Univ, Novosibirsk, Russia
[4] Helmholtz Zentrum Berlin, Berlin, Germany
基金
俄罗斯科学基金会;
关键词
Synchrotron radiation; diagnostics; electron-optical dissector; streak camera; picosecond;
D O I
10.1117/12.2524826
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this paper, we report on the development and manufacture of a dual-slit electron-optical dissector based on the PIF-01 streak image tube with a picosecond time resolution operating in the crossed-sweep mode. The dissector is designed to work on synchrotron radiation sources and electron-positron colliders, when it is necessary to record simultaneously the temporal profiles of electron and positron bunches filling from two to several hundred neighboring separatrices of an accelerator ring. In order to obtain the crossed-sweep mode, high-frequency (HF) sinusoidal voltages with multiple frequencies are fed to two pairs of deflecting plates of the tube, located perpendicular to each other. This separation of pulses will allow separate acquisition of the bunch profiles from neighboring separatrices of an accelerator, which are superimposed on each other in the absence of the crossed sweep. During the tests of the device which have been conducted on a laser system, two trains of light pulses, "shifted" in time with respect to each other, were recorded with a time resolution of 6 +/- 0.5 ps. Improvement of a single slit dissector was also done using the MASIM software. As a result, the temporal resolution of the modernized dissector measured on a femtosecond Ti:sapphire laser was about 1.5 ps. The dissector was tested on the MLS (Berlin, Germany) accelerator. Using both the HAMAMATSU C10910 streak camera and the dissector, comparative measurements of the longitudinal bunch length were performed.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] A Picosecond Image-Converter Dissector with a Crossed Sweep
    S. V. Andreev
    N. S. Vorobiev
    V. L. Dorokhov
    A. I. Zarovsky
    A. S. Komelkov
    G. Ya. Kurkin
    O. I. Meshkov
    A. V. Smirnov
    Instruments and Experimental Techniques, 2020, 63 : 87 - 91
  • [2] A Picosecond Image-Converter Dissector with a Crossed Sweep
    Andreev, S. V.
    Vorobiev, N. S.
    Dorokhov, V. L.
    Zarovsky, A. I.
    Komelkov, A. S.
    Kurkin, G. Ya.
    Meshkov, O. I.
    Smirnov, A. V.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2020, 63 (01) : 87 - 91
  • [3] Calibration of an image-tube picosecond dissector
    Anchugov O.V.
    Dorokhov V.L.
    Kurkin G.Y.
    Zinin E.I.
    Molyavin P.A.
    Meshkov O.I.
    Shvedov D.A.
    Petrozhitskii A.V.
    Gornostaev P.B.
    Zarovskii A.I.
    Shashkoff E.V.
    Smirnov A.V.
    Shchelev M.Y.
    Optoelectronics, Instrumentation and Data Processing, 2016, 52 (3) : 304 - 310
  • [4] A Picosecond Electron-Optical Dissector for Detecting Synchrotron Radiation
    S. V. Andreev
    O. V. Anchugov
    N. S. Vorob’ev
    V. L. Dorokhov
    A. I. Zarovskii
    A. S. Komel’kov
    S. A. Krutikhin
    G. Ya. Kurkin
    D. A. Malyutin
    A. V. Matveenko
    O. I. Meshkov
    A. V. Smirnov
    E. V. Shashkov
    Instruments and Experimental Techniques, 2019, 62 : 208 - 213
  • [5] A Picosecond Electron-Optical Dissector for Detecting Synchrotron Radiation
    Andreev, S. V.
    Anchugov, O. V.
    Vorob'ev, N. S.
    Dorokhov, V. L.
    Zarovskii, A. I.
    Komel'kov, A. S.
    Krutikhin, S. A.
    Kurkin, G. Ya.
    Malyutin, D. A.
    Matveenko, A. V.
    Meshkov, O. I.
    Smirnov, A. V.
    Shashkov, E. V.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2019, 62 (02) : 208 - 213
  • [6] Development, Calibration and Application of New-generation Dissector with Picosecond Temporal Resolution
    Meshkov, O. I.
    Zinin, E. I.
    Dorokhov, V. L.
    Anchugov, O. V.
    Kurkin, G. Ya.
    Shvedov, D. V.
    Petrozhitsky, A. N.
    Gornostaev, P. B.
    Zarovskii, A. I.
    Shashkov, E. V.
    Smirnov, A. V.
    Schelev, M. Ya.
    Vereshchagin, A. K.
    SELECTED PAPERS FROM THE 31ST INTERNATIONAL CONGRESS ON HIGH-SPEED IMAGING AND PHOTONICS, 2017, 10328
  • [7] A METHOD OF CROSSED TIME SWEEP FOR MEASURING PICOSECOND PROCESSES
    ARAKELYAN, SA
    BABUSHKIN, AV
    VOROBEV, NS
    GYUZALYAN, RN
    NERSISYAN, MN
    SMIRNOV, AV
    KVANTOVAYA ELEKTRONIKA, 1990, 17 (12): : 1576 - 1578
  • [8] PARAMETERS OF VIDEOTRACK OF ANALOG DISSECTOR ASTROSENSORS
    RUMYANTSEV, KE
    IZVESTIYA VYSSHIKH UCHEBNYKH ZAVEDENII RADIOELEKTRONIKA, 1994, 37 (1-2): : 26 - 38
  • [9] PARAPHASE SWEEP-VOLTAGE AMPLIFIER FOR THE LI-602 DISSECTOR.
    Bogomolov, G.D.
    Voronin, V.I.
    Instruments and Experimental Techniques (English Translation of Pribory I Tekhnika Eksperimenta), 1974, 17 (4 pt 2): : 1085 - 1086
  • [10] PARAMETRIC OPTIMIZATION OF THE DISSECTOR SYSTEM OF IMPULSE RADIATION SOURCE DETECTION
    BICHKOV, SI
    RUMYANTSEV, KY
    IZVESTIYA VYSSHIKH UCHEBNYKH ZAVEDENII RADIOELEKTRONIKA, 1986, 29 (05): : 12 - 18