Development of a new pulsatile extracorporeal life support device incorporating a dual pulsatile blood pump

被引:5
|
作者
Choi, S. W.
Nam, K. W.
Chung, J.
Lee, J. C.
Hwang, C. M.
Won, Y. S.
Sun, K.
Min, B. G.
机构
[1] Seoul Natl Univ, Grad Sch, Coll Med, Dept Biomed Engn,Interdisciplinary Program Biomed, Seoul 110744, South Korea
[2] Korea Univ, Korea Artificial Organ Ctr, Seoul 136701, South Korea
[3] Korea Univ, Coll Med, Seoul 136701, South Korea
[4] Soonchunhyang Univ, Coll Med, Dept Thorac & Cardiovasc Surg, Bucheon, South Korea
[5] Seoul Natl Univ, Coll Med, Dept Biomed Engn, Seoul, South Korea
[6] Med Res Ctr, Inst Med & Biol Engn, Seoul, South Korea
来源
关键词
dual pulsatile pump; extracorporeal life support device (ECLS); equivalent energy pressure (EEP);
D O I
10.1177/039139880602900607
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new pulsatile extracorporeal life support device (ECLS) has been developed, designed to sustain pulsatile blood flow during emergency cardiopulmonary resuscitations and cardiopulmonary operations. This device features two identical pulsatile pumps that operate alternately and can therefore provide blood inflow in a more uniform manner than similar systems featuring a single-pump configuration. In order to confirm the presumed benefits of this newly-developed dual pulsatile pump configuration, we have conducted a series of in vitro experiments designed to compare the properties of the new system with a single pump system, specifically with regard to pump delivery rate and active filling efficiency. Our results reveal that the dual pump configuration can, indeed, deliver a higher flow than can the single-pump system, and exhibits an active filling efficiency superior to that of the single-pump configuration. We performed a series of animal experiments to measure the pulsatility of the dual-pump configuration in terms of equivalent energy pressure (EEP). In order to measure EEP, we measured femoral arterial pressure and pump outflow. The results of our animal experiments revealed that the newly-developed pulstile ECLS exhibits sufficient pulsatility in terms of the EEP considerations.
引用
收藏
页码:583 / 590
页数:8
相关论文
共 50 条
  • [1] Novel Pulsatile Diagonal Pump for Pediatric Extracorporeal Life Support System
    Wang, Shigang
    Kunselman, Allen R.
    Uendar, Akif
    [J]. ARTIFICIAL ORGANS, 2013, 37 (01) : 37 - 47
  • [2] NEW EXTRACORPOREAL PULSATILE BYPASS PUMP WITH DISPOSABLE BLOOD CHAMBER
    ZARTNACK, F
    AFFELD, K
    HENNIG, E
    BUCHERL, ES
    [J]. ARTIFICIAL ORGANS, 1979, 3 (03) : 319 - 319
  • [3] DEVELOPMENT OF A PULSATILE BLOOD PUMP
    BALAKRISHNAN, S
    SRIDHAR, D
    [J]. BIOMATERIALS MEDICAL DEVICES AND ARTIFICIAL ORGANS, 1976, 4 (3-4): : 323 - 332
  • [4] Clinical experiences of a new pulsatile extracorporeal life support system
    Won, YS
    Shin, HK
    Her, K
    Park, YW
    Hong, JY
    Min, BG
    [J]. CIRCULATION, 2005, 112 (17) : U1198 - U1198
  • [5] Pulsatile control of a rotary blood pump - Therapy optimisation with extracorporeal lung support
    Kuehn, Jan
    Stollenwerk, Andre
    Kowalewski, Stefan
    Brendle, Christian
    Walter, Marian
    Leonhardt, Steffen
    Wardeh, Markus
    Rossaint, Rolf
    Kopp, Ruedger
    [J]. ATP EDITION, 2015, (10): : 52 - 59
  • [6] Hemoperfusion using a portable dual pulsatile extracorporeal life support on paraquat intoxication
    Kim, K
    Suh, G
    Kwak, Y
    Min, B
    [J]. ANNALS OF EMERGENCY MEDICINE, 2004, 44 (04) : S91 - S92
  • [7] Use of a Novel Diagonal Pump in an In Vitro Neonatal Pulsatile Extracorporeal Life Support Circuit
    Evenson, Alissa
    Wang, Shigang
    Kunselman, Allen R.
    Uendar, Akif
    [J]. ARTIFICIAL ORGANS, 2014, 38 (01) : E1 - E9
  • [8] PULSATILE BLOOD PUMP
    NOVAK, P
    BRAMM, G
    [J]. ARTIFICIAL ORGANS, 1979, 3 (03) : 308 - 308
  • [9] Venous Pressure Regulation During Pulsatile Extracorporeal Life Support
    Choi, Seong Wook
    Nam, Kyoung Won
    [J]. ARTIFICIAL ORGANS, 2008, 32 (10) : 822 - 827
  • [10] Pulsatile augmentation device for extracorporeal circulation
    Doty, DB
    Wang, ND
    Chiang, BY
    Mohammad, SF
    [J]. ARTIFICIAL ORGANS, 1996, 20 (12) : 1304 - 1309