Standardized Hydraulic Conductivity Testing of Compacted Sand-Bentonite Mixtures

被引:12
|
作者
Tong, S. [1 ,2 ]
Shackelford, C. D. [2 ]
机构
[1] Villanova Univ, Dept Civil & Environm Engn, 800 East Lancaster Ave, Villanova, PA 19085 USA
[2] Colorado State Univ, Dept Civil & Environm Engn, 1372 Campus Delivery, Ft Collins, CO 80523 USA
来源
GEOTECHNICAL TESTING JOURNAL | 2016年 / 39卷 / 06期
关键词
ASTM D5084-10; constant head; flexible-wall cell; hydraulic conductivity; sand-bentonite mixtures; FOUNDRY GREEN SANDS; CLAY LINERS; SOIL-BENTONITE; WATER-CONTENT; PERFORMANCE; CONSTRUCTION; PERMEABILITY; BARRIERS; CALCIUM; DESIGN;
D O I
10.1520/GTJ20150204
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Compacted sand-bentonite mixtures can be used as engineered barriers (liners) for waste containment applications. A primary consideration for such applications is the ability of the mixtures to achieve a suitably low hydraulic conductivity, k, typically <= 1.0 x 10(-9) m/s, based on permeation with water in the laboratory. The purpose of this study was to evaluate in a systematic manner the applicability of ASTM D5084-10 for the measurement of k of compacted sand-bentonite mixtures. Final degrees of saturation, S-f, for 4 of the 19 test specimens were outside of the required range 95 % <= S-f <= 105 %, even though the measured k values for these 4 specimens were consistent with those tested under the same conditions with values of Sf that met the standard. Thus, S-f apparently was an unreliable measure of true saturation for the materials tested in this study. Otherwise, the results indicated that conservatively high values of k were measured for the largest specimen size, the highest applied hydraulic gradient, and the highest ionic strength of the permeant water. A difference in the method of hydraulic gradient application had essentially no effect on the magnitude of k. Finally, as expected, specimens containing the highest amount of bentonite (i.e., 15 % by dry weight) resulted in the lowest values of k, although calculation of some values of k for one specimen were negative (k < 0), which was attributed to swelling of the specimen during permeation and the manner in which k was calculated based on ASTM D5084-10.
引用
收藏
页码:1015 / 1029
页数:15
相关论文
共 50 条
  • [1] HYDRAULIC CONDUCTIVITY OF COMPACTED BENTONITE SAND MIXTURES
    KENNEY, TC
    VANVEEN, WA
    SWALLOW, MA
    SUNGAILA, MA
    [J]. CANADIAN GEOTECHNICAL JOURNAL, 1992, 29 (03) : 364 - 374
  • [2] Network model for hydraulic conductivity of sand-bentonite mixtures
    Abichou, T
    Benson, CH
    Edil, TB
    [J]. CANADIAN GEOTECHNICAL JOURNAL, 2004, 41 (04) : 698 - 712
  • [3] Swelling of compacted sand-bentonite mixtures
    Sun, De'an
    Cui, Hongbin
    Sun, Wenjing
    [J]. APPLIED CLAY SCIENCE, 2009, 43 (3-4) : 485 - 492
  • [4] Hydraulic conductivity of zeolite-bentonite mixtures in comparison with sand-bentonite mixtures
    Oren, Ali Hakan
    Kaya, Abidin
    Kayalar, Arif Sengun
    [J]. CANADIAN GEOTECHNICAL JOURNAL, 2011, 48 (09) : 1343 - 1353
  • [5] Hydraulic Conductivity Prediction of Saturated Sand-Bentonite Mixtures
    Tripathi K.K.
    [J]. Tripathi, K. K. (kamalesht@gmail.com), 1600, Kluwer Academic Publishers (31): : 581 - 591
  • [6] Hydraulic conductivity and shear strength of dune sand-bentonite mixtures
    Department of Civil Engineering, University Amar Teledji Laghouat, Laghouat, Algeria
    不详
    不详
    [J]. Electron. J. Geotech. Eng, 2008,
  • [7] Discussion of "Network model for hydraulic conductivity of sand-bentonite mixtures"
    Chapuis, RP
    Marcotte, D
    Aubertin, M
    [J]. CANADIAN GEOTECHNICAL JOURNAL, 2006, 43 (01) : 110 - 114
  • [8] Determination of hydraulic conductivity of sand-bentonite mixtures for engineering purposes
    Sallfors G.
    Oberg-Hogsta A.-L.
    [J]. Geotechnical & Geological Engineering, 2002, 20 (1) : 65 - 80
  • [9] Experimental investigation of compacted sand-bentonite mixtures
    Proia, Roberta
    Croce, Paolo
    Modoni, Giuseppe
    [J]. VI ITALIAN CONFERENCE OF RESEARCHERS IN GEOTECHNICAL ENGINEERING, CNRIG2016 - GEOTECHNICAL ENGINEERING IN MULTIDISCIPLINARY RESEARCH: FROM MICROSCALE TO REGIONAL SCALE, 2016, 158 : 51 - 56
  • [10] Hydraulic Conductivity Determination of Compacted Sand-Bentonite Mixture Using Filter Press
    Rico, Razakamanantsoa A.
    Gilles, Barast
    Irini, Djeran-Maigre
    [J]. GEOTECHNICAL TESTING JOURNAL, 2011, 34 (01): : 9 - 17