Estimating Energy Expenditure with ActiGraph GT9X Inertial Measurement Unit

被引:39
|
作者
Hibbing, Paul R. [1 ]
Lamunion, Samuel R. [1 ]
Kaplan, Andrew S. [1 ]
Crouter, Scott E. [1 ]
机构
[1] Univ Tennessee, Dept Kinesiol Recreat & Sport Studies, 1914 Andy Holt Ave, Knoxville, TN 37996 USA
来源
关键词
ACCELEROMETER; GYROSCOPE; MAGNETOMETER; TWO-REGRESSION; MULTISENSOR; PHYSICAL-ACTIVITY; SINGLE ACCELEROMETER; ACTIVITY RECOGNITION; SEDENTARY BEHAVIOR; 2-REGRESSION MODEL; AMBULATORY SYSTEM; SENSORS; WRIST; VALIDATION; GYROSCOPE;
D O I
10.1249/MSS.0000000000001532
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose The purpose of this study was to explore whether gyroscope and magnetometer data from the ActiGraph GT9X improved accelerometer-based predictions of energy expenditure (EE). Methods Thirty participants (mean SD: age, 23.0 2.3 yr; body mass index, 25.2 +/- 3.9 kgm(-2)) volunteered to complete the study. Participants wore five GT9X monitors (right hip, both wrists, and both ankles) while performing 10 activities ranging from rest to running. A Cosmed K4b(2) was worn during the trial, as a criterion measure of EE (30-s averages) expressed in METs. Triaxial accelerometer data (80 Hz) were converted to milli-G using Euclidean norm minus one (ENMO; 1-s epochs). Gyroscope data (100 Hz) were expressed as a vector magnitude (GVM) in degrees per second (1-s epochs) and magnetometer data (100 Hz) were expressed as direction changes per 5 s. Minutes 4-6 of each activity were used for analysis. Three two-regression algorithms were developed for each wear location: 1) ENMO, 2) ENMO and GVM, and 3) ENMO, GVM, and direction changes. Leave-one-participant-out cross-validation was used to evaluate the root mean square error (RMSE) and mean absolute percent error (MAPE) of each algorithm. Results Adding gyroscope to accelerometer-only algorithms resulted in RMSE reductions between 0.0 METs (right wrist) and 0.17 METs (right ankle), and MAPE reductions between 0.1% (right wrist) and 6.0% (hip). When direction changes were added, RMSE changed by 0.03 METs and MAPE by 0.21%. Conclusions The combined use of gyroscope and accelerometer at the hip and ankles improved individual-level prediction of EE compared with accelerometer only. For the wrists, adding gyroscope produced negligible changes. The magnetometer did not meaningfully improve estimates for any algorithms.
引用
收藏
页码:1093 / 1102
页数:10
相关论文
共 50 条
  • [1] Enabling the ActiGraph GT9X Link's Idle Sleep Mode and Inertial Measurement Unit Settings Directly Impacts Data Acquisition
    Coyle-Asbil, Hannah J.
    Habegger, Janik
    Oliver, Michele
    Vallis, Lori Ann
    SENSORS, 2023, 23 (12)
  • [2] Validity Of The Actigraph GT9X Accelerometer For Measuring Step-counts And Energy Expenditure In Patients With Heart Failure
    Kim, Jisu
    Kenyon, Jonathan
    Billingsley, Hayley
    Bohmke, Natalie
    Ahmed, Syed Imran
    Salmons, Hannah
    Lei, Hao
    Lee, Jung-Min
    Kirkman, Danielle
    Carbone, Salvatore
    Kim, Youngdeok
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2023, 55 (09) : 385 - 385
  • [3] Research on energy consumption of college tennis players based on actigraph GT9X accelerometer
    Luo, Qi
    Sun, Lulu
    Zhou, Yu
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2019, 125 : 285 - 286
  • [4] Current Knowledge about ActiGraph GT9X Link Activity Monitor Accuracy and Validity in Measuring Steps and Energy Expenditure: A Systematic Review
    Suau, Quentin
    Bianchini, Edoardo
    Bellier, Alexandre
    Chardon, Matthias
    Milane, Tracy
    Hansen, Clint
    Vuillerme, Nicolas
    SENSORS, 2024, 24 (03)
  • [5] Physical Activity Category Classification Using The Actigraph Gt9x In Youth
    LaMunion, Samuel R.
    Hibbing, Paul R.
    Kaplan, Andrew S.
    Crouter, Scott E.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2018, 50 (05): : 295 - 295
  • [6] Application Of The ActiGraph GT9X IMU For The Assessment Of Turning During Walking And Running
    Marcotte, Robert T.
    Bassett, David R., Jr.
    Weinhandl, Joshua T.
    Crouter, Scott E.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2018, 50 (05): : 584 - 585
  • [7] Application of the ActiGraph GT9X IMU for the assessment of turning during walking and running
    Marcotte, Robert T.
    Bassett, David R., Jr.
    Weinhandl, Joshua T.
    Crouter, Scott E.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (06):
  • [8] Research on establishing energy consumption prediction equation of college tennis players based on Actigraph GT9X
    He, Tianyu
    Luo, Qi
    Wan, Tong
    Zhou, Yu
    Sun, Lulu
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2019, 125 : 136 - 137
  • [9] Reliability Study of Inertial Sensors LIS2DH12 Compared to ActiGraph GT9X: Based on Free Code
    Martin-Martin, Jaime
    Jimenez-Partinen, Ariadna
    De-Torres, Irene
    Escriche-Escuder, Adrian
    Gonzalez-Sanchez, Manuel
    Muro-Culebras, Antonio
    Roldan-Jimenez, Cristina
    Ruiz-Munoz, Maria
    Mayoral-Cleries, Fermin
    Biro, Attila
    Tang, Wen
    Nikolova, Borjanka
    Salvatore, Alfredo
    Cuesta-Vargas, Antonio, I
    JOURNAL OF PERSONALIZED MEDICINE, 2022, 12 (05):
  • [10] The effect of college students' exercise and sedentary behavior on obesity based on ActiGraph GT9X
    Luo, Qi
    Wan, Tong
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2019, 125 : 223 - 224