Quantification of Electromechanical Coupling to Prevent Inappropriate Implantable Cardioverter-Defibrillator Shocks

被引:7
|
作者
Keene, Daniel [1 ,2 ]
Shun-Shin, Matthew J. [1 ,2 ]
Arnold, Ahran D. [1 ,2 ]
Howard, James P. [1 ,2 ]
Lefroy, David [1 ]
Davies, D. Wyn [1 ]
Lim, Phang Boon [1 ,2 ]
Ng, Fu Siong [1 ,2 ]
Koa-Wing, Michael [1 ,2 ]
Qureshi, Norman A. [1 ,2 ]
Linton, Nick W. F. [1 ,2 ]
Shah, Jaymin S. [1 ]
Peters, Nicholas S. [1 ,2 ]
Kanagaratnam, Prapa [1 ,2 ]
Francis, Darrel P. [1 ,2 ]
Whinnett, Zachary, I [1 ,2 ]
机构
[1] Imperial Coll Hosp Natl Hlth Serv Trust, Dept Cardiol, London, England
[2] Imperial Coll London, Natl Heart & Lung Inst, London, England
关键词
arrhythmia discrimination; hemodynamic monitoring; implantable cardioverter-defibrillator; inappropriate therapy; laser Doppler perfusion monitoring;
D O I
10.1016/j.jacep.2019.01.025
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study sought to test specialized processing of laser Doppler signals for discriminating ventricular fibrillation (VF) from common causes of inappropriate therapies. BACKGROUND Inappropriate implantable cardioverter-defibrillator (ICD) therapies remain a clinically important problem associated with morbidity and mortality. Tissue perfusion biomarkers, implemented to assist automated diagnosis of VF, sometimes mistake artifacts and random noise for perfusion, which could lead to shocks being inappropriately withheld. METHODS The study tested a novel processing algorithm that combines electrogram data and laser Doppler perfusion monitoring as a method for assessing circulatory status. Fifty patients undergoing VF induction during ICD implantation were recruited. Noninvasive laser Doppler and continuous electrograms were recorded during both sinus rhythm and VF. Two additional scenarios that might have led to inappropriate shocks were simulated for each patient: ventricular lead fracture and T-wave oversensing. The laser Doppler was analyzed using 3 methods for reducing noise: 1) running mean; 2) oscillatory height; and 3) a novel quantification of electromechanical coupling which gates laser Doppler relative to electrograms. In addition, the algorithm was tested during exercise-induced sinus tachycardia. RESULTS Only the electromechanical coupling algorithm found a clear perfusion cut off between sinus rhythm and VF (sensitivity and specificity of 100%). Sensitivity and specificity remained at 100% during simulated lead fracture and electrogram oversensing. (Area under the curve running mean: 0.91; oscillatory height: 0.86; electromechanical coupling: 1.00). Sinus tachycardia did not cause false positive results. CONCLUSIONS Quantifying the coupling between electrical and perfusion signals increases reliability of discrimination between VF and artifacts that ICDs may interpret as VF. Incorporating such methods into future ICDs may safely permit reductions of inappropriate shocks. Crown Copyright (C) 2019 Published by Elsevier on behalf of the American College of Cardiology Foundation.
引用
收藏
页码:705 / 715
页数:11
相关论文
共 50 条
  • [1] Inappropriate implantable cardioverter-defibrillator shocks in MADIT II
    Daubert, James P.
    Zareba, Wojciech
    Cannom, David S.
    McNitt, Scott
    Rosero, Spencer Z.
    Wang, Paul
    Schuger, Claudio
    Steinberg, Jonathan S.
    Higgins, Steven L.
    Wilber, David J.
    Klein, Helmut
    Andrews, Mark L.
    Hall, W. Jackson
    Moss, Arthur J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (14) : 1357 - 1365
  • [2] Methods of minimizing inappropriate implantable cardioverter-defibrillator shocks
    Schaer B.
    Osswald S.
    [J]. Current Cardiology Reports, 2000, 2 (4) : 346 - 352
  • [3] THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - EVALUATING SUSPECTED INAPPROPRIATE SHOCKS
    CHAPMAN, PD
    TROUP, P
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (05) : 1075 - 1078
  • [4] Inappropriate implantable cardioverter-defibrillator shocks in a public swimming pool
    Alzand, Becker S. N.
    Leemput, Niels
    Willems, Rik
    [J]. EUROPACE, 2014, 16 (08): : 1124 - 1124
  • [5] Implantable cardioverter-defibrillator shocks
    Raitt, Merritt H.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (14) : 1366 - 1368
  • [6] Inappropriate implantable cardioverter-defibrillator shocks due to temporary epicardial pacing
    Gelissen, Marloes
    Debie, Luuk
    van Opstal, Jurren
    [J]. EUROPACE, 2010, 12 (11): : 1648 - 1648
  • [7] Do Inappropriate Implantable Cardioverter-defibrillator Shocks Generate Additional Costs?
    Pereferrer Kleiner, Damia
    Sicras Mainar, Antoni
    Villuendas Sabate, Roger
    Alcalde Rodriguez, Oscar
    Labata Salvador, Carles
    Bayes-Genis, Antoni
    [J]. REVISTA ESPANOLA DE CARDIOLOGIA, 2014, 67 (01): : 65 - 66
  • [8] Inappropriate Implantable Cardioverter-Defibrillator Shocks Incidence, Predictors, and Impact on Mortality
    van Rees, Johannes B.
    Borleffs, C. Jan Willem
    de Bie, Mihaly K.
    Stijnen, Theo
    van Erven, Lieselot
    Bax, Jeroen J.
    Schalij, Martin J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (05) : 556 - 562
  • [9] Minimizing Inappropriate or "Unnecessary" Implantable Cardioverter-Defibrillator Shocks Appropriate Programming
    Koneru, Jayanthi N.
    Swerdlow, Charles D.
    Wood, Mark A.
    Ellenbogen, Kenneth A.
    [J]. CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2011, 4 (05): : 778 - 790
  • [10] RISK FACTORS FOR APPROPRIATE CARDIOVERTER-DEFIBRILLATOR SHOCKS, INAPPROPRIATE CARDIOVERTER-DEFIBRILLATOR SHOCKS, AND MORTALITY IN 549 PATIENTS WITH HEART FAILURE AND IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS
    Aronow, Wilbert S.
    Desai, Harit
    Gandhi, Kaushang
    Ahn, Chul
    Hussain, Sadaf
    Lai, Hoang M.
    Sharma, Mala
    Frishman, William H.
    Cohen, Martin
    Sorbera, Carmine
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)