Ultrafiltration significantly increased the scaling potential of municipal secondary effluent on reverse osmosis membranes

被引:14
|
作者
Tong, Xin [1 ]
Zhang, Zi-Wei [1 ]
Wu, Yin-Hu [1 ,2 ]
Bai, Yuan [1 ]
Ikuno, Nozomu [3 ]
Ishii, Kazuki [3 ]
Hu, Hong-Ying [1 ,4 ]
机构
[1] Tsinghua Univ, Sch Environm, Environm Simulat & Pollut Control State Key Joint, State Environm Protect Key Lab Microorganism Appli, Room 524, Beijing 100084, Peoples R China
[2] Beijing Lab Environm Frontier Technol, Beijing 100084, Peoples R China
[3] Kurita Water Ind Ltd, Nakano Ku, Tokyo 1640001, Japan
[4] Res Inst Environm Innovat Suzhou, Suzhou 215163, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Ultrafiltration pretreatment; Reverse osmosis membrane fouling; Scaling; Antiscaling effect; DEAD-END ULTRAFILTRATION; WATER DESALINATION; NANOFILTRATION MEMBRANE; FOULING CHARACTERISTICS; ORGANIC FOULANTS; RO MEMBRANES; GYPSUM; PLANT; PRECIPITATION; PRETREATMENT;
D O I
10.1016/j.watres.2022.118672
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Ultrafiltration (UF) was often used as pretreatment in front of reverse osmosis (RO) unit because of its high rejection efficiency of microbes and particles. However, in some cases UF pretreatment might show adverse effects on the RO membrane flux. In this study, the effects of UF pretreatment on secondary effluent water quality and its RO membrane fouling characteristics were explored. There was almost no change of water quality after UF with different molecular weight cut-off (MWCO) membranes (100, 30 and 10 kDa), including total dissolved solid (TDS), alkalinity, conductivity, ion concentrations, etc., while pH increased a little and dissolved organic carbon (DOC) declined by about 1 mg/L. On the contrary, the RO membrane flux of UF permeates presented clear decline in comparison to the secondary effluent. The membrane fouling velocity and steady-state flux of secondary effluent was 0.052 and 0.656, while fouling velocity increased (0.077, 0.071, 0.067) and steady-state flux decreased significantly (0.397, 0.416, 0.448) after 100, 30, 10 kDa UF membrane pretreatment. Scanning electron microscope (SEM) images showed many crystals on the fouled membrane surfaces, which turned out to be CaCO3 by Energy dispersive spectrometer (EDS) analysis and precipitation calculation. After the addition of UF retentates to UF permeates, scaling was prevented and crystals on the RO membrane almost disappeared, which implied the anti-scaling effect of the UF retentates with low concentration. According to anti-scaling performance experiments, the anti-scaling performance of 100 k, 30 k, 10 k retentates was 2.7%, 4.0% and 7.3%, respectively. Excitation emission matrix (EEM) and fourier transform infra-red (FTIR) results showed that these retentates retained by different MWCO membranes were similar and composed of protein-like substances and soluble microbial products. The effect of key minority components in RO system deserved further exploration.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Impact of microfiltration treatment of secondary wastewater effluent on biofouling of reverse osmosis membranes
    Herzberg, Moshe
    Berry, David
    Raskin, Lutgarde
    WATER RESEARCH, 2010, 44 (01) : 167 - 176
  • [2] HYBRID REVERSE-OSMOSIS - ULTRAFILTRATION MEMBRANES
    SACHS, SB
    ZISNER, E
    HERSCOVICI, G
    DESALINATION, 1976, 18 (02) : 99 - 111
  • [3] SEPARATION BY ULTRAFILTRATION AND REVERSE OSMOSIS WITH ANISOTROPIC MEMBRANES
    VANOSS, CJ
    BRONSON, PM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1971, (NSEP): : 45 - &
  • [4] Fouling behavior and foulant characteristics of reverse osmosis membranes for treated secondary effluent reclamation
    Zhao, Yan
    Song, Lianfa
    Ong, Say Leong
    JOURNAL OF MEMBRANE SCIENCE, 2010, 349 (1-2) : 65 - 74
  • [5] Impact of anti-scalant on fouling of reverse osmosis membranes in reclamation of secondary effluent
    Qin, J. J.
    Wai, M. N.
    Oo, M. H.
    Kekre, K. A.
    Seah, H.
    WATER SCIENCE AND TECHNOLOGY, 2009, 60 (11) : 2767 - 2774
  • [6] REVERSE-OSMOSIS TREATMENT OF SECONDARY EFFLUENT OF MUNICIPAL WASTEWATER FOR REUSE AS BOILER FEED WATER
    KURATA, A
    SANGA, S
    KAGAKU KOGAKU RONBUNSHU, 1982, 8 (06) : 693 - 698
  • [7] Fouling of reverse osmosis and ultrafiltration membranes: A critical review
    Goosen, MFA
    Sablani, SS
    Ai-Hinai, H
    Ai-Obeidani, S
    Al-Belushi, R
    Jackson, D
    SEPARATION SCIENCE AND TECHNOLOGY, 2004, 39 (10) : 2261 - 2297
  • [8] MATERIALS SCIENCE OF REVERSE-OSMOSIS-ULTRAFILTRATION MEMBRANES
    MATSUURA, T
    SOURIRAJAN, S
    ACS SYMPOSIUM SERIES, 1985, 281 : 1 - 19
  • [9] Investigations of silica scaling on reverse osmosis membranes
    Braun, Gerd
    Hater, Wolfgang
    Zum Kolk, Christian
    Dupoiron, Claire
    Harrer, Timo
    Goetz, Thomas
    DESALINATION, 2010, 250 (03) : 982 - 984
  • [10] THE MAJOR DEVELOPMENTS OF THE EVOLVING REVERSE-OSMOSIS MEMBRANES AND ULTRAFILTRATION MEMBRANES
    KURIHARA, M
    HIMESHIMA, Y