Digital retroilluminated photography to analyze posterior capsule opacification in eyes with intraocular lenses

被引:32
|
作者
Wang, MC [1 ]
Woung, LC [1 ]
机构
[1] Taipei Municipal Yang Ming Hosp, Dept Ophthalmol, Taipei, Taiwan
来源
关键词
D O I
10.1016/S0886-3350(99)00332-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the formation and rates of posterior capsule opacification (PCO) in eyes with poly(methyl methacrylate) (PMMA) versus silicone intraocular lenses (IOLs) using an in vivo objective method. Setting: Taipei Municipal Yang-Ming Hospital, Taipei, Taiwan, Republic of China. Methods: This prospective study comprised 40 eyes with senile cataract receiving phacoemulsification with capsular implantation of an IOL from March to April 1997. The uneventful surgeries were performed using the stop and chop method by the same surgeon. Twenty eyes received a PMMA IOL (Pharmacia 812A) and 20, a silicone IOL (AMO SI-30NB). One year later, digital retroillumination images 1000 anterior segment analysis system (Nidek) were used to 3.0 and 5.0 mm optic zones and evaluate the degree of PCO over the central and peripheral zones. Results: Over the central 5.0 mm optic zone, mean transparency of the capsule was 87.71% +/- 11.35% (SD) in the silicone group and 79.22% +/- 21.10% in the PMMA group (P = .17). Over the central 3.0 mm optic zone, the means were 97.17% +/- 5.96% and 86.32% +/- 19.60%, respectively (P = .048). Mean opacity in the central zone was 75.18 +/- 13.22 digital opacity units (OUs) in the silicone group and 80.24 +/- 7.93 OUs in the PMMA groups (P = .18). The means in the peripheral zone were 88.49 +/- 18.47 OUs and 90.35 +/- 9.98 OUs, respectively (P = .71). Conclusion: The posterior capsule in the silicone IOL group was more transparent than in the PMMA IOL group over the central 3.0 mm optic zone after 1 year follow-up. 61 (C) 2000 ASCRS and ESCRS.
引用
收藏
页码:56 / 61
页数:6
相关论文
共 50 条
  • [1] INCIDENCE OF POSTERIOR CAPSULE OPACIFICATION IN EYES WITH AND WITHOUT POSTERIOR CHAMBER INTRAOCULAR LENSES
    NISHI, O
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1986, 12 (05): : 519 - 522
  • [2] ANTERIOR CAPSULE OPACIFICATION IN MONKEY EYES WITH POSTERIOR CHAMBER INTRAOCULAR LENSES
    ISHIBASHI, T
    ARAKI, H
    SUGAI, S
    TAWARA, A
    OHNISHI, Y
    INOMATA, H
    ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (12) : 1685 - 1690
  • [3] Clinical evaluation of posterior capsule opacification in eyes with different small-incision intraocular lenses
    Yoshida, S
    Senoo, T
    Fujikake, F
    Obara, Y
    OPHTHALMIC SURGERY AND LASERS, 2002, 33 (06): : 450 - 455
  • [4] Effect of four different intraocular lenses on posterior capsule opacification
    Rahmi Duman
    Fatih Karel
    Pelin ?zyol
    Can Ates
    International Journal of Ophthalmology, 2015, (01) : 118 - 121
  • [5] Effect of four different intraocular lenses on posterior capsule opacification
    Duman, Rahmi
    Karel, Fatih
    Ozyol, Pelin
    Ates, Can
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2015, 8 (01) : 118 - 121
  • [6] Rate of posterior capsule opacification in eyes with the Akreos intraocular lens
    Khandwala, Mona A.
    Marjnovic, Branka
    Kotagiri, Ajay K.
    Teimory, Masoud
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (08): : 1409 - 1413
  • [7] INCIDENCE OF POSTERIOR CAPSULE OPACIFICATION IN EYES WITH EXFOLIATION SYNDROME AND HEPARIN-SURFACE-MODIFIED INTRAOCULAR LENSES
    ZETTERSTROM, C
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (03): : 344 - 347
  • [8] Posterior capsule opacification in rabbit eyes implanted with hydrophilic acrylic intraocular lenses with enhanced square edge
    Werner, L
    Mamalis, N
    Pandey, SK
    Izak, AM
    Nilson, CD
    Davis, BL
    Weight, C
    Apple, DJ
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (11): : 2403 - 2409
  • [9] Epidemiological evaluation of YAG capsulotomy incidence for posterior capsule opacification in various intraocular lenses in Japanese eyes
    Nishi, Yutaro
    Ikeda, Tomohiro
    Nishi, Kayo
    Mimura, Osamu
    CLINICAL OPHTHALMOLOGY, 2015, 9 : 1613 - 1617
  • [10] Quantification of posterior capsule opacification with round and sharp edge intraocular lenses
    Auffarth, GU
    Golescu, A
    Becker, KA
    Völcker, HE
    OPHTHALMOLOGY, 2003, 110 (04) : 772 - 780