The performance characteristics of a novel multi-electrode electromagnetic flowmeter

被引:7
|
作者
Bates, CJ
Franklin, B
机构
[1] Univ Wales Coll Cardiff, Cardiff Sch Engn, Div Mech Engn, Cardiff CF2 3TA, S Glam, Wales
[2] ABB Automat, Stonehouse GL10 3TA, Glos, England
关键词
electromagnetic flowmeters; header tank; velocity profiles;
D O I
10.1016/j.measurement.2004.03.008
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The design of a novel multi-electrode electromagnetic flowmeter, which provides nine conventional electromagnetic flowmeters housed in a single body, has been used in adverse flow conditions immediately downstream from a header tank. The results show that careful initial calibration, in accord with the pipeline conditions recommended in international standards, enables errors of under 1% to be achieved. The results show that the two electrode planes closest to the header provide results with the greatest errors. The performance with the electrodes mounted in the vertical plane is generally better than that achieved with the electrodes mounted in the horizontal plane. Pressure measurements together with laser Doppler anemometry (LDA) and particle image velocimetry (PIV) techniques have been used to provide details of the magnitude of the disturbance caused to the flow field by the header and outflow combination. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:399 / 408
页数:10
相关论文
共 50 条
  • [1] Multi-electrode electromagnetic flowmeter
    Guan, J
    Zhang, HJ
    Hu, CY
    [J]. PROCEEDINGS OF THE SECOND INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, VOL 1, 2002, : 325 - 330
  • [2] Phase Sensitive Detector for Multi-electrode Electromagnetic Flowmeter
    Gao, Kai
    Cui, Ziqiang
    Xia, Zihan
    Wang, Huaxiang
    [J]. 2021 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC 2021), 2021,
  • [3] Optimum estimation of the mean flow velocity for the multi-electrode inductance flowmeter
    Xu, LJ
    Li, XM
    Dong, F
    Wang, Y
    Xu, LA
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2001, 12 (08) : 1139 - 1146
  • [4] Lesion Characteristics Using a Novel Multi-Electrode Radiofrequency Balloon Ablation Catheter
    Lee, Byron K.
    Al-Ahmad, Amin
    Rippy, Marian
    Reddy, Vivek
    Narayan, Girish
    Kuck, Karl-Heinz
    Crozier, Ian
    Daly, Matt
    Melton, Iain
    Walters, Tomas E.
    Lee, Randall J.
    Badhwar, Nitish
    [J]. CIRCULATION, 2016, 134
  • [5] Novel Contact Lens Electrode Array for Multi-electrode Electroretinography (meERG)
    Selner, A. N.
    Ban, T.
    Williams, J.
    Thongpang, S.
    Hetling, J. R.
    [J]. 2011 IEEE 37TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE (NEBEC), 2011,
  • [6] On-line monitoring of non-axisymmetric flow profile with a multi-electrode inductance flowmeter
    Xu, LJ
    Wang, Y
    Dong, F
    Yan, Y
    [J]. IMTC/O3: PROCEEDINGS OF THE 20TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1 AND 2, 2003, : 1541 - 1546
  • [7] Research of Electromagnetic Flowmeter with Grounding Electrode
    Gao, Song
    Li, Bin
    Yin, Shi Yi
    [J]. ADVANCES IN MANUFACTURING SCIENCE AND ENGINEERING, PTS 1-4, 2013, 712-715 : 1856 - 1862
  • [8] Numerical Study of the Output Characteristics of a Multi-Electrode Semiconductor Laser
    Nithin, V
    Shenoy, M. R.
    [J]. 2017 IEEE WORKSHOP ON RECENT ADVANCES IN PHOTONICS (WRAP), 2017,
  • [9] Novel method for electrode-tissue contact measurement with multi-electrode catheters
    van Es, Ren
    Hauck, John
    van Driel, Vincent J. H. M.
    Neven, Kars
    van Wessel, Harry
    A Doevendans, Pieter
    Wittkampf, Fred H. M.
    [J]. EUROPACE, 2018, 20 (01): : 149 - 156
  • [10] Validation of a novel method for electrode-tissue measurements with multi-electrode catheters
    Groen, M. H.
    van Es, R.
    Neven, K.
    van Driel, V. J.
    Doevendans, P. A.
    Wittkampf, F. H.
    [J]. EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2017, 47 : 104 - 105