Temporal performance assessment of wastewater treatment plants by using multivariate statistical analysis

被引:65
|
作者
Ebrahimi, Milad [1 ]
Gerber, Erin L. [2 ]
Rockaway, Thomas D. [1 ]
机构
[1] Univ Louisville, Dept Civil & Environm Engn, Ctr Infrastruct Res, Louisville, KY 40292 USA
[2] Univ Louisville, Dept Ind Engn, Louisville, KY 40292 USA
关键词
Municipal wastewater; Wastewater Quality Index; Correlation; Principal component analysis; Multivariate regression analysis; PRINCIPAL COMPONENT ANALYSIS; INDEX CCME WQI; QUALITY INDEX; RIVER-BASIN; CANADIAN COUNCIL; SLUDGE; PARAMETERS; OPERATION; MINISTERS; PCA;
D O I
10.1016/j.jenvman.2017.02.027
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
For most water treatment plants, a significant number of performance data variables are attained on a time series basis. Due to the interconnectedness of the variables, it is often difficult to assess over -arching trends and quantify operational performance. The objective of this study was to establish simple and reliable predictive models to correlate target variables with specific measured parameters. This study presents a multivariate analysis of the physicochemical parameters of municipal wastewater. Fifteen quality and quantity parameters were analyzed using data recorded from 2010 to 2016. To determine the overall quality condition of raw and treated wastewater, a Wastewater Quality Index (WWQI) was developed. The index summarizes a large amount of measured quality parameters into a single water quality term by considering pre -established quality limitation standards. To identify treatment process performance, the interdependencies between the variables were determined by using Principal Component Analysis (PCA). The five extracted components from the 15 variables accounted for 75.25% of total dataset information and adequately represented the organic, nutrient, oxygen demanding, and ion activity loadings of influent and effluent streams. The study also utilized the model to predict quality parameters such as Biological Oxygen Demand (BOD), Total Phosphorus (TP), and WWQI. High accuracies ranging from 71% to 97% were achieved for fitting the models with the training dataset and relative prediction percentage errors less than 9% were achieved for the testing dataset. The presented techniques and procedures in this paper provide an assessment framework for the wastewater treatment monitoring programs.(C)2017 Elesvier Ltd.All rights reserved.
引用
收藏
页码:234 / 246
页数:13
相关论文
共 50 条
  • [1] Performance Assessment of Natural Wastewater Treatment Plants by Multivariate Statistical Models: A Case Study
    Gad, Mahmoud
    Abdo, Sayeda M.
    Hu, Anyi
    El-Liethy, Mohamed Azab
    Hellal, Mohamed S.
    Doma, Hala S.
    Ali, Gamila H.
    SUSTAINABILITY, 2022, 14 (13)
  • [2] Multivariate statistical monitoring of continuous wastewater treatment plants
    Aguado, Daniel
    Rosen, Christian
    ENGINEERING APPLICATIONS OF ARTIFICIAL INTELLIGENCE, 2008, 21 (07) : 1080 - 1091
  • [3] Performance assessment of Al-Rustumiah wastewater treatment plant using multivariate statistical technique
    Mahmood, Wesam
    Hatem, Wadhah Amer
    APPLIED WATER SCIENCE, 2024, 14 (04)
  • [4] Performance assessment of Al-Rustumiah wastewater treatment plant using multivariate statistical technique
    Wesam Mahmood
    Wadhah Amer Hatem
    Applied Water Science, 2024, 14
  • [5] ASSESSMENT OF EFFLUENT QUALITY OF WASTEWATER TREATMENT PLANTS IN GUANGYUAN (CHINA) BASED ON MULTIVARIATE STATISTICAL TECHNIQUES
    Yu, M. L.
    Tang, Y.
    Da, W. Y.
    Zhang, Y. M.
    Quan, Q. M.
    JOURNAL OF ENVIRONMENTAL PROTECTION AND ECOLOGY, 2019, 20 (01): : 52 - 63
  • [6] An assessment of resistome and mobilome in wastewater treatment plants through temporal and spatial metagenomic analysis
    Yin, Xiaole
    Yang, Yu
    Deng, Yu
    Huang, Yue
    Li, Liguan
    Chan, Lilian Y. L.
    Zhang, Tong
    WATER RESEARCH, 2022, 209
  • [7] Energy and environmental performance of wastewater treatment plants: A statistical approach
    Moreno, Renan
    Correia, Manuela
    Martins, Florinda
    4TH INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT RESEARCH, ICEER 2017, 2017, 136 : 296 - 301
  • [8] Prediction of Wastewater Treatment Plant Performance Using Multivariate Statistical Analysis: A Case Study of a Regional Sewage Treatment Plant in Melaka, Malaysia
    Rahmat, Sofiah
    Altowayti, Wahid Ali Hamood
    Othman, Norzila
    Asharuddin, Syazwani Mohd
    Saeed, Faisal
    Basurra, Shadi
    Eisa, Taiseer Abdalla Elfadil
    Shahir, Shafinaz
    WATER, 2022, 14 (20)
  • [9] MULTIVARIATE CONTROL PERFORMANCE ASSESSMENT OF MPC IN WASTEWATER TREATMENT PROCESS
    Liu Hongbin
    Shen Wenhao
    Lim, JungJin
    Kim, MinJung
    Yoo, ChangKyoo
    RESEARCH PROGRESS IN PAPER INDUSTRY AND BIOREFINERY (4TH ISETPP), VOLS 1-3, 2010, : 1083 - 1086
  • [10] Fish canning industry wastewater variability assessment using multivariate statistical methods
    Cristovao, Raquel O.
    Pinto, Victor M. S.
    Goncalves, Antonio
    Martins, Ramiro J. E.
    Loureiro, Jose M.
    Boaventura, Rui A. R.
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2016, 102 : 263 - 276