Adaptive cubic interpolation of CT slices for maximum intensity projection

被引:2
|
作者
Kwon, J [1 ]
Yi, JW [1 ]
Songa, SMH [1 ]
机构
[1] Seoul Natl Univ, Coll Engn, Seoul 151742, South Korea
关键词
maximum intensity projection (MIP); image interpolation; linear interpolation; cubic interpolation;
D O I
10.1117/12.535075
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
Three-dimensional visualization of medical images, using maximum intensity projection (MIP), requires isotropic volume data for the generation of realistic and undistorted 3-D views. However, the distance between CT slices is usually larger than the pixel spacing within each slice. Therefore, before the MIP operation, these axial slice images must be interpolated for the preparation of the isotropic data set. Of many available interpolation techniques, linear interpolation is most popularly used for such slice interpolation due to its computational simplicity. However, as resulting MIP's depend heavily upon the variance in interpolated slices (due to the inherent noise), MIP's of linearly interpolated slices suffer from horizontal streaking artifacts when the projection direction is parallel to the axial slice (e.g., sagittal and coronal views). In this paper, we propose an adaptive cubic interpolation technique to minimize these horizontal streaking artifacts in MIP's due to the variation of the variance across interpolated slices. The proposed technique, designed for near-constant variance distribution across interpolated slices, will be shown to be superior over the linear interpolation technique by completely eliminating the horizontal streaking artifacts in MIP's of simulated data set and real CT data set.
引用
收藏
页码:837 / 844
页数:8
相关论文
共 50 条
  • [1] Interpolation of CT slices for 3-d visualization by maximum intensity projections
    Song, SMH
    Kwon, J
    ADVANCES IN MULTIMEDIA INFORMATION PROCESSING - PCM 2002, PROCEEDING, 2002, 2532 : 1065 - 1072
  • [2] CT ANGIOGRAPHY WITH SPIRAL CT AND MAXIMUM INTENSITY PROJECTION
    NAPEL, S
    MARKS, MP
    RUBIN, GD
    DAKE, MD
    MCDONNELL, CH
    SONG, SM
    ENZMANN, DR
    JEFFREY, RB
    RADIOLOGY, 1992, 185 (02) : 607 - 610
  • [3] Band-limited interpolation for maximum intensity projection images
    Kim, S
    Song, SMH
    Kim, NH
    Lee, G
    Kreang-arekul, S
    Iwase, A
    Taylor, R
    HIGH-SPEED IMAGING AND SEQUENCE ANALYSIS III, 2001, 4308 : 78 - 85
  • [4] Index-based interpolation for maximum-intensity projection display
    Huang, ST
    Horng, MH
    Sun, YN
    IMAGE DISPLAY - MEDICAL IMAGING 1997, 1997, 3031 : 563 - 570
  • [5] CT angiography: Shaded surface versus maximum intensity projection
    Alberico, RA
    Ozsvath, R
    Casey, S
    Patel, M
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (05) : 1227 - 1228
  • [6] A Comparison of Lung Tumor Shadow on Maximum Intensity Projection and Average Intensity Projection of Respiratory Correlated Simulation CT
    Tsudou, S.
    Takegawa, H.
    Takashina, M.
    Numasaki, H.
    Teshima, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S564 - S564
  • [7] CT angiography: Shaded surface versus maximum intensity projection - Reply
    Vieco, PT
    Zeman, RK
    Silverman, PM
    Costello, P
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (05) : 1228 - 1229
  • [8] Maximum Intensity Projection images review - Is there a role in Cardiac PET/CT?
    Muthu, S.
    Shawgi, M.
    Goldstone, A.
    James, J.
    Arumugam, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S320 - S321
  • [9] Improved on Maximum intensity projection
    Ling, Feng
    Yang, Ling
    2009 INTERNATIONAL CONFERENCE ON ARTIFICIAL INTELLIGENCE AND COMPUTATIONAL INTELLIGENCE, VOL IV, PROCEEDINGS, 2009, : 491 - 495
  • [10] INTERPOLATION OF CT SLICES FOR LASER STEREOLITHOGRAPHY
    NAGAE, T
    AGUI, T
    NAGAHASHI, H
    IEICE TRANSACTIONS ON INFORMATION AND SYSTEMS, 1993, E76D (08) : 905 - 911