Optical quality and intraocular scattering assessed with a double-pass system in eyes with contact lens induced corneal swelling

被引:10
|
作者
de Juan, Victoria [1 ]
Aldaba, Mikel [2 ]
Martin, Raul [1 ,3 ]
Vilaseca, Meritxell [2 ]
Maria Herreras, Jose [1 ]
Pujol, Jaume [2 ]
机构
[1] Univ Valladolid, Inst Eye, IOBA, Valladolid, Spain
[2] Tech Univ Catalonia, Ctr Sensors Instruments & Syst Dev CD6, Barcelona, Spain
[3] Univ Valladolid, Sch Optometry, Dept Phys & Opt, Valladolid, Spain
来源
CONTACT LENS & ANTERIOR EYE | 2014年 / 37卷 / 04期
关键词
Contact lens; Overnight; Contact swelling; Optical quality; Scattering; RETINAL IMAGE QUALITY; COHERENCE TOMOGRAPHY; EXTENDED WEAR; THICKNESS; PERFORMANCE; INSTRUMENT;
D O I
10.1016/j.clae.2014.02.003
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the impact of contact lens (CL)-induced corneal swelling on the optical quality of the eye by means of the double-pass technique. Methods: Measurements of 6 healthy subjects were obtained in 5 visits over 1 week, at baseline and after sleeping with 4 different CLs of +0.50 D, +2.00 D, +5.00 D and +8.00 D (Acuvue2), randomly fitted on 4 different days. The control eye wore no CL Corneal pachymetry and optical quality of the eye (OQAS, Visiometrics) were measured once at baseline and at three interval times in the follow-up.visits: immediately after CL removal, and 1 and 2 h after CL removal. Optical quality was evaluated by means of the Strehl ratio and OQAS values at 100%, 20% and 9% contrasts. Intraocular scattering was evaluated with the objective scatter index (OSI). Results: Mean overnight swelling was 5.98 4.29% in CL-eyes versus 0.30 0.78% in control eyes (p <0.01). Corneal swelling was maximal immediately after CL removal and decreased with time (p <0.01). A significant worsening in all optical quality parameters and a significant increase of the OSI were found in eyes with corneal swelling (p < 0.05). Two hours after CL removal there were no statistically significant differences (p >0.05) between CL-eyes and control eyes in any of the measured parameters. Conclusions: Corneal swelling has a significant impact on the optical quality of the eye and on intraocular scattering as assessed with the double-pass technique. (C) 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:278 / 284
页数:7
相关论文
共 20 条
  • [1] Double-Pass System Assessing the Optical Quality of Pseudophakic Eyes
    Lee, Hun
    Lee, Kwanghyun
    Ahn, Ji Min
    Kim, Eung Kweon
    Sgrignoli, Bradford
    Kim, Tae-im
    OPTOMETRY AND VISION SCIENCE, 2014, 91 (04) : 437 - 443
  • [2] Effect of Aging on Optical Quality and Intraocular Scattering Using the Double-Pass Instrument
    Kamiya, Kazutaka
    Umeda, Kyoko
    Kobashi, Hidenaga
    Shimizu, Kimiya
    Kawamorita, Takushi
    Uozato, Hiroshi
    CURRENT EYE RESEARCH, 2012, 37 (10) : 884 - 888
  • [3] Longitudinal Assessment of Optical Quality and Intraocular Scattering Using the Double-Pass Instrument in Normal Eyes and Eyes with Short Tear Breakup Time
    Kobashi, Hidenaga
    Kamiya, Kazutaka
    Yanome, Kyohei
    Igarashi, Akihito
    Shimizu, Kimiya
    PLOS ONE, 2013, 8 (12):
  • [4] THE REVERSIBILITY OF THE EYES OPTICAL-SYSTEM IN DOUBLE-PASS MEASUREMENTS OF RETINAL IMAGE QUALITY
    ARTAL, P
    IGLESIAS, I
    LOPEZ, N
    GREEN, DG
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S188 - S188
  • [5] Double-pass system analysis of the visual outcomes and optical performance of an apodized diffractive multifocal intraocular lens
    Moreno, Luis J.
    Pinero, David P.
    Alio, Jorge L.
    Fimia, Antonio
    Plaza, Ana B.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (12): : 2048 - 2055
  • [6] Double-pass measurements of retinal image quality in monofocal contact lens wearers
    Torrents, A
    Gispets, J
    Pujol, J
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1997, 17 (04) : 357 - 366
  • [7] Double-Pass System (Optical Quality Analysis System) for Analysis of the Multifocal Function of a Diffractive Multifocal Inlraocular Lens (Acrysof ReSTOR®) Compared to a Monofocal Intraocular Lens (Acrysof IQ®))
    Hwang, Ho Sik
    Shin, Hye Young
    Joo, Choun-Ki
    JOURNAL OF THE OPTICAL SOCIETY OF KOREA, 2014, 18 (02) : 110 - 117
  • [8] Optical quality assessment in normal and forme fruste keratoconus eyes with a double-pass system: a comparison and variability study
    Ye, Cong
    Ng, Paul Ka-Fai
    Jhanji, Vishal
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2014, 98 (11) : 1478 - 1483
  • [9] Comparison of Optical Quality and Intraocular Scattering after Posterior Chamber Phakic Intraocular Lens with and without a Central Hole (Hole ICL and Conventional ICL) Implantation Using the Double-Pass Instrument
    Kamiya, Kazutaka
    Shimizu, Kimiya
    Saito, Aya
    Igarashi, Akihito
    Kobashi, Hidenaga
    PLOS ONE, 2013, 8 (06):
  • [10] Effect of Pupil Size on Optical Quality Parameters in Astigmatic Eyes Using a Double-Pass Instrument
    Kobashi, Hidenaga
    Kamiya, Kazutaka
    Yanome, Kyohei
    Igarashi, Akihito
    Shimizu, Kimiya
    BIOMED RESEARCH INTERNATIONAL, 2013, 2013