Retrograde suction decompression of a large internal carotid aneurysm using a balloon guide catheter combined with a blood-returning circuit and STA-MCA bypass: a technical note

被引:8
|
作者
Matano, Fumihiro [1 ]
Mizunari, Takayuki [1 ]
Kominami, Shushi [1 ]
Suzuki, Masanori [1 ]
Fujiki, Yu [1 ]
Kubota, Asami [1 ]
Kobayashi, Shiro [1 ]
Murai, Yasuo [2 ]
Morita, Akio [2 ]
机构
[1] Chiba Hokusoh Hosp, Dept Neurosurg, 1715 Kamagari, Inzai, Chiba 2701694, Japan
[2] Nippon Med Sch, Dept Neurol Surg, Tokyo, Japan
关键词
Aneurysm; Balloon catheter; Suction decompression; SEGMENT ANEURYSMS; OCCLUSION; SERIES;
D O I
10.1007/s10143-016-0808-6
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
It is difficult to treat large internal carotid aneurysms with simple surgical clipping. Here, we present a retrograde suction decompression (RSD) procedure for large internal carotid aneurysms using a balloon guide catheter combined with a blood-returning circuit and a superficial temporal artery to middle cerebral artery (STA-MCA) bypass. All patients underwent an STA-MCA bypass before the temporary occlusion of the internal carotid artery (ICA). A 6-French sheath was inserted into the common carotid artery (CCA), and a 6-French Patrive balloon catheter was placed into the ICA 5 cm past the bifurcation. Aneurysm exposure was obtained; temporary clips were placed on the proximal M1, A1, and posterior communicating (Pcom) segments; and an extension tube was then connected to the balloon catheter. A three-way stopcock was placed, and aspiration was performed through the device to collapse the aneurysm. The aspirated blood was returned to a venous line with an added heparin to prevent anemia after aspiration. During the decompression, the blood flow to the cortical area was supplied through the STA-MCA bypass. After the aneurysm collapse, the surgeon carefully dissected the perforating artery from the aneurysm dome or neck, and permanent clips were then placed on the aneurysm neck. Our procedure has several advantages, such as STA-MCA bypass without external carotid artery occlusion for preventing ischemic complications of the cortical area, anemia may be avoided because of the return of the aspirated blood, and a hybrid operation room is not required to perform this method.
引用
收藏
页码:351 / 355
页数:5
相关论文
共 3 条
  • [1] Retrograde suction decompression of a large internal carotid aneurysm using a balloon guide catheter combined with a blood-returning circuit and STA-MCA bypass: a technical note
    Fumihiro Matano
    Takayuki Mizunari
    Shushi Kominami
    Masanori Suzuki
    Yu Fujiki
    Asami Kubota
    Shiro Kobayashi
    Yasuo Murai
    Akio Morita
    Neurosurgical Review, 2017, 40 : 351 - 355
  • [2] RETROGRADE SUCTION DECOMPRESSION OF AN OPHTHALMIC ARTERY ANEURYSM USING BALLOON OCCLUSION - TECHNICAL NOTE
    SCOTT, JA
    HORNER, TG
    LEIPZIG, TJ
    JOURNAL OF NEUROSURGERY, 1991, 75 (01) : 146 - 147
  • [3] Retrograde suction decompression of giant paraclinoid aneurysms using a No. 7 French balloon-containing guide catheter - Technical note
    Parkinson, Richard J.
    Bendok, Bernard R.
    Getch, Christopher. C.
    Yashar, Parham
    Shaibani, Ali
    Ankenbrandt, William
    Awad, Issam A.
    Batjer, H. Hunt
    JOURNAL OF NEUROSURGERY, 2006, 105 (03) : 479 - 481