Diagnosis of high-Z plasma with soft X-ray laser probe

被引:1
|
作者
Wang Chen [1 ]
An Hong-Hai [1 ]
Jia Guo [1 ]
Fang Zhi-Heng [1 ]
Wang Wei [1 ]
Meng Xiang-Fu [1 ]
Xie Zhi-Yong [1 ]
Wang Shi-Ji [1 ]
机构
[1] Shanghai Inst Laser Plasma, Shanghai 201800, Peoples R China
基金
中国国家自然科学基金;
关键词
diagnoses of plasma; laser probe technique; soft X-ray laser; high-Z plasma; ELECTRON-DENSITY; INTERFEROMETRY;
D O I
10.7498/aps.63.215203
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
It is important to diagnose electron density of a plasma irradiated by lasers for inertial confinement fusion, in high energy density physics and related fields, especially for measuring high-Z plasma near the interface. Use of soft X-ray laser as a probe is an important method in diagnosis of plasma electron density distribution. However, it is difficult to carry out the research in high-Z laser plasma, because of the problem of excessive plasma spontaneous radiation. In view of the characteristics of soft X-ray laser, several specific experimental techniques have been developed. By using these techniques, which can greatly suppress effects of spontaneous radiation, diagnosis of high-Z plasma with soft X-ray laser probe method becomes possible. As a typical example, an experiment of diagnosing gold plasma is performed and clear images are obtained, indicating that the techniques are effective and feasible.
引用
收藏
页数:6
相关论文
共 17 条
  • [1] Baidis H. A., 2002, REV SCI INSTRUM, V73, P4223
  • [2] MICRON-RESOLUTION RADIOGRAPHY OF LASER-ACCELERATED AND X-RAY HEATED FOILS WITH AN X-RAY LASER
    CAUBLE, R
    DASILVA, LB
    BARBEE, TW
    CELLIERS, P
    MORENO, JC
    WAN, AS
    [J]. PHYSICAL REVIEW LETTERS, 1995, 74 (19) : 3816 - 3819
  • [3] ELECTRON-DENSITY MEASUREMENTS OF HIGH-DENSITY PLASMAS USING SOFT-X-RAY LASER INTERFEROMETRY
    DASILVA, LB
    BARBEE, TW
    CAUBLE, R
    CELLIERS, P
    CIARLO, D
    LIBBY, S
    LONDON, RA
    MATTHEWS, D
    MROWKA, S
    MORENO, JC
    RESS, D
    TREBES, JE
    WAN, AS
    WEBER, F
    [J]. PHYSICAL REVIEW LETTERS, 1995, 74 (20) : 3991 - 3994
  • [4] Dense plasma diagnostics with an amplitude-division soft-x-ray laser interferometer based on diffraction gratings
    Filevich, J
    Kanizay, K
    Marconi, MC
    Chilla, JLA
    Rocca, JJ
    [J]. OPTICS LETTERS, 2000, 25 (05) : 356 - 358
  • [5] Measurement of the degree of spatial coherence of high-order harmonics using a Fresnel-mirror interferometer -: art. no. 043802
    Le Déroff, L
    Salières, P
    Carré, B
    Joyeux, D
    Phalippou, D
    [J]. PHYSICAL REVIEW A, 2000, 61 (04): : 9
  • [6] Plasma characterization on carbon fiber cathode by spectroscopic diagnostics
    College of Photoelectric Science and Engineering, National University of Defense Technology, Changsha 410073, China
    [J]. Chin. Phys., 2009, 8 (3367-3372):
  • [7] Peng H M, 2008, RAD TRANSPORT RAD HY, P178
  • [8] MEASUREMENT OF LASER-PLASMA ELECTRON-DENSITY WITH A SOFT-X-RAY LASER DEFLECTOMETER
    RESS, D
    DASILVA, LB
    LONDON, RA
    TREBES, JE
    MROWKA, S
    PROCASSINI, RJ
    BARBEE, TW
    LEHR, DE
    [J]. SCIENCE, 1994, 265 (5171) : 514 - 517
  • [9] Soft-x-ray laser interferometry of a plasma with a tabletop laser and a Lloyd's mirror
    Rocca, JJ
    Moreno, CH
    Marconi, MC
    Kanizay, K
    [J]. OPTICS LETTERS, 1999, 24 (06) : 420 - 422
  • [10] Experimental diagnoses of plasma electron density by interferometry using an x-ray laser as probe
    Wang, C
    Wang, W
    Sun, JR
    Fang, ZH
    Wu, J
    Fu, SZ
    Ma, WX
    Gu, Y
    Wang, SJ
    Zhang, GP
    Zheng, WD
    Zhang, TX
    Peng, HM
    Shao, P
    Yi, K
    Lin, ZQ
    Wang, ZS
    Wang, HC
    Zhou, B
    Chen, LY
    Jin, CS
    [J]. ACTA PHYSICA SINICA, 2005, 54 (01) : 202 - 205