A simple analytic method for cone beam calibration

被引:0
|
作者
Mennessier, Catherine [1 ]
Clackdoyle, Rolf [1 ]
机构
[1] CPE Sch, Lab TSI, Lyon, France
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In cone-beam tomography, for accurate image reconstruction to be achieved, the system first has to be calibrated. Few methods exist for direct cone-beam scanner calibration. The advantages of direct methods is. that they do not need human intervention and can be very general With respect to the source/detector trajectory. With the assumption of a vertical scanner, Noo et al [10] obtained analytic equations for the calibration parameters with respect to the projected images of a calibration object. Without assumptions on the scanner geometry, a simple and direct method is described here, using a calibration object made of three orthogonal line segments with a common center. First, the projected center is identified. Then, three intermediate vectors are calculated from the data. Then, intrinsic (focal length and principal point) and extrinsic (rotation angles and translation vector from the calibration object to the scanner) parameters are obtained analytically from the three vectors.
引用
收藏
页码:2743 / 2746
页数:4
相关论文
共 50 条
  • [1] An analytic geometric calibration method for circular cone-beam CT
    Xu, Jingyan
    Tsui, Benjamin
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [2] Analytic calibration of cone-beam scanners
    Strubel, Gregory
    Clackdoyle, Rolf
    Mennessier, Catherine
    Noo, Frederic
    [J]. 2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2731 - 2735
  • [3] Analytic method based on identification of ellipse parameters for scanner calibration in cone-beam tomography
    Noo, F
    Clackdoyle, R
    Mennessier, C
    White, TA
    Roney, TJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (11): : 3489 - 3508
  • [4] A simple and precise alignment calibration method for cone-beam computed tomography with the verifications
    Shih, Kun-Long
    Jin, David Shih-Chun
    Wang, Yu-Hong
    Tran, Trang Thi Ngoc
    Chen, Jyh-Cheng
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (06):
  • [5] Analytic non-iterative method for geometric calibration of cone-beam computerized tomography system
    Cho, Y
    Moseley, D
    Siewerdsen, J
    Jaffray, D
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1450 - 1450
  • [6] A geometric calibration method for cone beam CT systems
    Yang, Kai
    Kwan, Alexander L. C.
    Miller, DeWitt F.
    Boone, John M.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 1695 - 1706
  • [7] A geometric calibration method for cone beam CT system
    Xiang Qian
    Wang Jue
    Cai Yufang
    [J]. EIGHTH INTERNATIONAL CONFERENCE ON DIGITAL IMAGE PROCESSING (ICDIP 2016), 2016, 10033
  • [8] A Practical Geometric Calibration Method of Cone-Beam CT System Using Simple Handmade Phantom
    Wu, S. Y.
    Li, H. W.
    Qi, H. L.
    Luo, Y. B.
    Zhen, X.
    Xu, Y.
    Zhou, L. H.
    [J]. JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2015, 5 (08) : 1915 - 1920
  • [9] Geometry calibration method for a cone-beam CT system
    Yang, Hongkai
    Kang, Kejun
    Xing, Yuxiang
    [J]. MEDICAL PHYSICS, 2017, 44 (05) : 1692 - 1706
  • [10] An Analytical Geometric Calibration Method for Circular Cone-Beam Geometry
    Xu, Jingyan
    Tsui, Benjamin M. W.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (09) : 1731 - 1744