Flow cytometric analysis of micronucleated reticulocytes in mouse bone marrow

被引:17
|
作者
Dertinger, SD
Torous, DK
Tometsko, KR
机构
[1] Litron Laboratories, 1351 Mount Hope Avenue, Rochester
关键词
micronucleus test; flow cytometry; clastogenicity; bone marrow; automated analysis; transferrin receptor; CD71; antigen;
D O I
10.1016/S1383-5718(97)00022-3
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
This laboratory has previously reported a flow cytometric procedure for quantitatively analyzing mouse peripheral blood reticulocytes for micronucleus content. The current study extends this line of investigation by evaluating whether these same flow cytometric scaring procedures can be applied to the analysis of mouse bone marrow samples. To validate the method, three groups of male BALB/c mice were treated with 100 mg/kg b.wt. methyl methanesulfonate. Bone marrow samples were collected 20, 40 or 60 h after administration. A set of 5 untreated animals was included to provide an indication of spontaneous micronucleus frequencies. The cells were fixed with ultracold methanol, treated with ribonuclease, and labeled with anti-CD71 antibody (FITC conjugate) and propidium iodide. This fixing and labeling procedure resulted in the resolution of the micronucleated reticulocyte population and facilitated high-speed acquisition and enumeration via flow cytometry, The number of micronucleated reticulocytes was determined flow cytometrically by the analysis of 10000 total reticulocytes per bone marrow sample. In addition to these automated measurements, slides stained with acridine orange were prepared and the number of micronuclei per 1000 reticulocytes was determined microscopically for each sample. The resulting data demonstrate that flow cytometry can effectively enumerate micronucleated reticulocytes in mouse bone marrow. The advantages associated with an objective, high throughput scoring methodology are also clearly indicated.
引用
下载
收藏
页码:257 / 262
页数:6
相关论文
共 50 条
  • [1] Flow cytometric evaluation of micronucleated polychromatic erythrocytes in bone marrow and micronucleated reticulocytes in peripheral blood following acute and repeat dosing regimen of chemicals
    Shi, J.
    Krsmanovic, B.
    Torcus, D.
    ENVIRONMENTAL AND MOLECULAR MUTAGENESIS, 2008, 49 (07) : 566 - 566
  • [2] Flow cytometric analysis of micronucleated reticulocytes in mice after multiple blood sampling
    De Boeck, M
    van der Leede, BM
    De Smedt, A
    Steemans, M
    Van Goethem, F
    ENVIRONMENTAL AND MOLECULAR MUTAGENESIS, 2004, 44 (03) : 194 - 194
  • [3] Flow-cytometric quantitation of micronucleated nascent reticulocytes as a measure of bone marrow chromosome damage after 131-iodineradiotherapy
    Grawé, J
    Kotova, N
    CYTOMETRY, 2002, : 93 - 93
  • [4] Enumeration of micronucleated reticulocytes in rat peripheral blood: a flow cytometric study
    Torous, DK
    Dertinger, SD
    Hall, NE
    Tometsko, CR
    MUTATION RESEARCH-GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS, 2000, 465 (1-2) : 91 - 99
  • [5] Flow cytometric enumeration of micronucleated reticulocytes: High transferability among 14 laboratories
    Torous, DK
    Hall, NE
    Dertinger, SD
    Diehl, MS
    Illi-Love, AH
    Cederbrant, K
    Sandelin, K
    Bolcsfoldi, G
    Ferguson, LR
    Pearson, A
    Majeska, JB
    Tarca, JP
    Hewish, DR
    Doughty, L
    Fenech, M
    Weaver, JL
    Broud, DD
    Gatehouse, DG
    Hynes, GM
    Kwanyuen, P
    McLean, J
    McNamee, JP
    Parenteau, M
    Van Hoof, V
    Vanparys, P
    Lenarczyk, M
    Siennicka, J
    Litwinska, B
    Slowikowska, MG
    Harbach, PR
    Johnson, CW
    Zhao, S
    Aaron, CS
    Lynch, AM
    Marshall, IC
    Rodgers, B
    Tometsko, CR
    ENVIRONMENTAL AND MOLECULAR MUTAGENESIS, 2001, 38 (01) : 59 - 68
  • [6] Flow Cytometric Scoring of Micronucleated Reticulocytes as a Possible High-Throughput Radiation Biodosimeter
    Liu, Libo
    Liu, Yuguang
    Ni, Guangying
    Liu, Shuzheng
    ENVIRONMENTAL AND MOLECULAR MUTAGENESIS, 2010, 51 (03) : 215 - 221
  • [7] Flow cytometric analysis of micronuclei in mouse bone marrow: Method refinement.
    Torous, D. K.
    Krsmanovic, L. J.
    Escobar, P. A.
    Sugunan, S.
    Dertinger, S. D.
    ENVIRONMENTAL AND MOLECULAR MUTAGENESIS, 2006, 47 (06) : 441 - 441
  • [8] FLOW CYTOMETRIC ANALYSIS OF FELINE RETICULOCYTES
    REAGAN, WJ
    VAP, LM
    WEISER, MG
    VETERINARY PATHOLOGY, 1992, 29 (06) : 503 - 508
  • [9] Response kinetics of radiation-induced micronucleated reticulocytes in human bone marrow culture
    Sun, Hongliang
    Tsai, Ying
    Nowak, Irena
    Dertinger, Stephen D.
    Wu, J. H. David
    Chen, Yuhchyau
    MUTATION RESEARCH-GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS, 2011, 718 (1-2) : 38 - 43
  • [10] FLOW CYTOMETRIC DETECTION OF ERYTHROPOIETIC CYTOTOXICITY IN MOUSE BONE-MARROW
    BENNING, VM
    MARATRAT, MB
    FOURNIER, EC
    MELCION, CP
    CORDIER, AC
    JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1991, 39 (01) : 15 - 21