High-resolution photoluminescence electro-modulation microscopy by scanning lock-in

被引:2
|
作者
Koopman, W. [1 ,2 ]
Muccini, M. [2 ]
Toffanin, S. [2 ]
机构
[1] Univ Potsdam, Inst Phys & Astron, Karl Liebknecht Str 24-25, D-14476 Potsdam, Germany
[2] CNR ISMN Bologna, Via P Gobetti 101, I-40129 Bologna, BO, Italy
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2018年 / 89卷 / 04期
基金
欧盟地平线“2020”;
关键词
FIELD-EFFECT TRANSISTORS; THIN-FILMS; CHARGE-DISTRIBUTION; CHANNEL; PARAMETERS;
D O I
10.1063/1.5010281
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Morphological inhomogeneities and structural defects in organic semiconductors crucially determine the charge accumulation and lateral transport in organic thin-film transistors. Photoluminescence Electro-Modulation (PLEM) microscopy is a laser-scanning microscopy technique that relies on the modulation of the thin-film fluorescence in the presence of charge-carriers to image the spatial distribution of charges within the active organic semiconductor. Here, we present a lock-in scheme based on a scanning beam approach for increasing the PLEM microscopy resolution and contrast. The charge density in the device is modulated by a sinusoidal electrical signal, phase-locked to the scanning beam of the excitation laser. The lock-in detection scheme is achieved by acquiring a series of images with different phases between the beam scan and the electrical modulation. Application of high resolution PLEM to an organic transistor in accumulation mode demonstrates its potential to image local variations in the charge accumulation. A diffraction-limited precision of sub-300 nm and a signal to noise ratio of 21.4 dB could be achieved. Published by AIP Publishing.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] HIGH-RESOLUTION SCANNING ION MICROSCOPY
    SCHWARZSCHILD, BM
    PHYSICS TODAY, 1982, 35 (07) : 20 - 22
  • [2] Improving the resolution of lock-in measurements by tailoring the modulation
    Peronio, Angelo
    Dri, Carlo
    Comelli, Giovanni
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2013, 24 (10)
  • [3] Contact Resistance in Ambipolar Organic Field-Effect Transistors Measured by Confocal Photoluminescence Electro-Modulation Microscopy
    Koopman, Wouter W. A.
    Natali, Marco
    Bettini, Cristian
    Melucci, Manuela
    Muccini, Michele
    Toffanin, Stefano
    ACS APPLIED MATERIALS & INTERFACES, 2018, 10 (41) : 35411 - 35419
  • [4] High-Resolution Analog Quadrature Sine Oscillator for Lock-in Amplifiers Applications
    Garcia-Romeo, D.
    Martinez, P. A.
    Calvo, B.
    Medrano, N.
    2014 IEEE SENSORS, 2014,
  • [5] Multichannel Hybrid Lock-In Amplifier for High-Resolution Broadband Raman Spectroscopy
    Gubello, Giulio
    D'Onofrio, Alberto
    Polli, Dario
    Cerullo, Giulio
    Ferrari, Giorgio
    2024 31ST IEEE INTERNATIONAL CONFERENCE ON ELECTRONICS, CIRCUITS AND SYSTEMS, ICECS, 2024,
  • [6] A USB high resolution lock-in photometer
    Bateson S.
    AIMS Electronics and Electrical Engineering, 2019, 3 (01): : 1 - 15
  • [7] HIGH-RESOLUTION SCANNING ELECTRON-MICROSCOPY
    JOY, DC
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1990, (98): : 443 - 446
  • [8] Towards High-Resolution Scanning Magnetoresistance Microscopy
    Costa, Margaret
    Tarequzzaman, Mohammad
    Ferreira, Ricardo
    Cardoso, Susana
    Gaspar, Joao
    Freitas, Paulo P.
    2017 IEEE 12TH INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS (NEMS), 2017, : 73 - 76
  • [9] High-resolution scanning tunneling microscopy for molecules
    Li, B
    Wang, HQ
    Yang, JL
    Hou, JG
    ULTRAMICROSCOPY, 2004, 98 (2-4) : 317 - 334
  • [10] HIGH-RESOLUTION SCANNING ELECTRON-MICROSCOPY
    JOY, DC
    PAWLEY, JB