Simulation of a Current Source with a Cole-Cole Load for multi-frequency Electrical Impedance Tomography

被引:0
|
作者
Santos, Susana Aguiar [1 ]
Schlebusch, Thomas [1 ]
Leonhardt, Steffen [1 ]
机构
[1] Rhein Westfal TH Aachen, Philips Chair Med Informat, Aachen, Germany
关键词
Electrical Impedance Tomography (EIT); Improved Howland current source; Cole-Cole model; CIRCUIT;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An accurate current source is one of the keys in the hardware of Electrical impedance Tomography systems. Limitations appear mainly at higher frequencies and for non-simple resistive loads. In this paper, we simulate an improved Howland current source with a Cole-Cole load. Simulations comparing two different op-amps (THS4021 and OPA843) were performed at 1 kHz to 1 MHz. Results show that the THS4021 performed better than the OPA843. The current source with THS4021 reaches an output impedance of 20 M Omega at 1 kHz and above 320 k Omega at 1 MHz, it provides a constant and stable output current up to 4 mA, in the complete range of frequencies, and for Cole-Cole (resistive and capacitive) load.
引用
收藏
页码:6445 / 6448
页数:4
相关论文
共 50 条
  • [1] Study of Precision Constant Current Sources with Resistor Load and a Cole-Cole Load For Multi-Frequency in Electrical Impedance Tomography
    Puspitasari, Ayu Jati
    Endarko
    [J]. 2016 INTERNATIONAL SEMINAR ON SENSORS, INSTRUMENTATION, MEASUREMENT AND METROLOGY (ISSIMM), 2016, : 12 - 17
  • [2] Multi-frequency bioelectrical impedance: A comparison between the Cole-Cole modelling and Hanai equations with the classical impedance index approach
    Deurenberg, P
    Andreoli, A
    deLorenzo, A
    [J]. ANNALS OF HUMAN BIOLOGY, 1996, 23 (01) : 31 - 40
  • [3] Preliminary study of a Cole-Cole model curve fitting method for electrical impedance tomography
    He, Y.
    Wang, W.
    Sze, G.
    Qiao, G.
    Gu, Da-Wei
    Bramer, B.
    [J]. 13TH INTERNATIONAL CONFERENCE ON ELECTRICAL BIOIMPEDANCE AND THE 8TH CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY 2007, 2007, 17 : 436 - +
  • [4] Verifying of the Multi-Frequency Current Source for Electrical Impedance Tomography
    Huang, J. J.
    Wu, R. J.
    Cheng, K. S.
    [J]. 4TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2008, VOLS 1 AND 2, 2008, 21 (1-2): : 694 - +
  • [5] Design of current source for multi-frequency simultaneous electrical impedance tomography
    Han, Bing
    Xu, Yanbin
    Dong, Feng
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (09):
  • [6] Algorithm for the inversion of the Cole-Cole model from the real part of electrical impedance
    Miranda, D. A.
    Barrero, J. G.
    [J]. IV LATIN AMERICAN CONGRESS ON BIOMEDICAL ENGINEERING 2007, BIOENGINEERING SOLUTIONS FOR LATIN AMERICA HEALTH, VOLS 1 AND 2, 2008, 18 (1,2): : 578 - 582
  • [7] Cole-Cole Model Parameter Estimation from Multi-frequency Complex Resistivity Spectrum Based on the Artificial Neural Network
    Liu, Weiqiang
    Chen, Rujun
    Yang, Liangyong
    [J]. JOURNAL OF ENVIRONMENTAL AND ENGINEERING GEOPHYSICS, 2021, 26 (01) : 71 - 77
  • [8] A Cole-Cole Dielectric Relaxation Analysis of Albumin and γ-Globulins for Protein Quantification by Electrical Impedance Spectroscopy
    Sifuna, Martin Wekesa
    Baidillah, Marlin Ramadhan
    Sapkota, Achyut
    Takei, Masahiro
    [J]. ELECTROANALYSIS, 2020, 32 (05) : 1121 - 1129
  • [9] Electrical impedance estimation for apple fruit tissues during storage using Cole-Cole plots
    Watanabe, Takashi
    Ando, Yasumasa
    Orikasa, Takahiro
    Kasai, Satoshi
    Shiina, Takeo
    [J]. JOURNAL OF FOOD ENGINEERING, 2018, 221 : 29 - 34
  • [10] Multi-frequency Electrical Impedance Tomography and Magnetic Resonance Electrical Impedance Tomography
    Seo, Jin Keun
    Woo, Eung Je
    [J]. MATHEMATICAL MODELING IN BIOMEDICAL IMAGING I: ELECTRICAL AND ULTRASOUND TOMOGRAPHIES, ANOMALY DETECTION, AND BRAIN IMAGING, 2009, 1983 : 1 - 71