Evaluation of a new microbeads assay for granulocyte antibody detection

被引:17
|
作者
Schulz, Undine [1 ]
Reil, Angelika [2 ]
Kiefel, Volker [3 ]
Bux, Juergen [4 ]
Moog, Rainer [1 ]
机构
[1] DRK Blood Serv North East, Cottbus, Germany
[2] DRK Blood Serv West, Hagen, Germany
[3] Univ Rostock, Dept Transfus Med, Rostock, Germany
[4] Ruhr Univ Bochum, Bochum, Germany
关键词
ACUTE LUNG INJURY; TRANSPORTER-LIKE PROTEIN-2; TRANSFECTED CELL-LINES; TRALI; ALLOANTIBODIES; PATHOGENESIS; FATALITIES; MODEL; 5B;
D O I
10.1111/trf.13878
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: To reduce the risk of transfusion-associated acute lung injury (TRALI), a high number of plasma donors were tested for human leukocyte antigen (HLA) and human neutrophil antigen (HNA) antibodies. For HNA antibody detection, the gold standard is a combination of the granulocyte immunofluorescence test (GIFT) and the granulocyte agglutination test (GAT). However, these tests are not suitable for a high-throughput of samples. STUDY DESIGN AND METHODS: To evaluate the new generation of the LABScreen MULTI assay (One Lambda, Inc.), which has special new beads for all the known HNA specificities, including HNA-3a, 97 sera samples containing well-defined HNA antibodies were used. For background testing, we used 91 samples from plasma donors previously identified by GAT, GIFT, and the monoclonal antibody-specific immobilization of granulocyte antigens (MAIGA) assay. RESULTS: Compared with previous tests, the new LABScreen MULTI assay was highly specific for the HNA-1a, HNA-1b, HNA-2, and HNA-3a antibody specificities required to prevent TRALI. Ninety-eight percent of the HNA-1a, HNA-1b, and HNA-2 antibodies could be detected as true positive; and 90% of the HNA-3a antibodies were recognized correctly as positive. False-positive reactions were identified in 5.5% of samples that previously tested negative. CONCLUSION: The detection of HNA-3a antibody specificities could be integrated into the new LABScreen MULTI assay; however, we detected only 90%. In addition, we detected further HNA antibodies, such as HNA-1c, HNA-1d, and some HNA-3b and HNA-4a antibodies. The new generation of LABScreen MULTI is a great step toward feasible high-throughput testing for HNA antibodies. Nevertheless, GIFT and GAT remain the gold-standard methods for the differentiation of rare and currently unknown HNA specificities.
引用
收藏
页码:70 / 81
页数:12
相关论文
共 50 条
  • [1] Evaluation of the Microbeads Assay LabScreen Multi for Granulocyte Antibody Detection
    Schulz, U.
    Reil, A.
    Moog, R.
    Kiefel, V.
    TRANSFUSION, 2015, 55 : 122A - 122A
  • [2] Granulocyte antigens and antibody detection
    Stroncek, D
    VOX SANGUINIS, 2004, 87 : 91 - 94
  • [3] Standardization of the anti-HLA antibody detection by the microbeads assay in the 6 tissue typing laboratories of Switzerland
    Tiercy, Jean-Marie
    Schaub, Stefan
    Aubert, Vincent
    Urs, Wirthmueller
    Thomas, Fehr
    Thierbach, Jutta
    Villard, Jean
    TISSUE ANTIGENS, 2009, 73 (05): : 458 - 458
  • [4] Granulocyte antibody screening: evaluation of a bead-based assay in comparison with classical methods
    Fromont, Patricia
    Prie, Nolwen
    Simon, Philippe
    Cesbron-Gautier, Anne
    Quelvennec, Erwann
    Bignon, Jean-Denis
    Muller, Jean-Yves
    Audrain, Marie
    TRANSFUSION, 2010, 50 (12) : 2643 - 2648
  • [5] GRANULOCYTE ANTIBODY DETECTION - THE ROLE OF MPHA
    Tsuno, N. H.
    VOX SANGUINIS, 2011, 101 : 21 - 21
  • [6] Anti-granulocyte antibody detection by solid-phase assay using a magnetic force
    Mazda, T.
    Kamada, H.
    Tamai, T.
    Watanabe, Y.
    Okazaki, H.
    Tadokoro, K.
    VOX SANGUINIS, 2006, 91 : 229 - 229
  • [7] Evaluation Of The Antibody In Lymphocyte Supernatant Assay In Detection Of Active Tuberculosis
    Sariko, M.
    Anderson, C.
    Mujaga, B.
    Gratz, J.
    Mpagama, S.
    Heysell, S. K.
    Kibiki, G.
    Mmbaga, B.
    Houpt, E.
    Thomas, T. A.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193
  • [8] Evaluation of a new enzyme-linked immunosorbent assay for detection of Chagas antibody in US blood donors
    Tobler, Leslie H.
    Contestable, Paul
    Pitina, Lubor
    Groth, Holly
    Shaffer, Shirley
    Blackburn, Gary R.
    Warren, Harold
    Lee, Stephen R.
    Busch, Michael P.
    TRANSFUSION, 2007, 47 (01) : 90 - 96
  • [9] EVALUATION OF A NEW IMMUNODIAGNOSTIC ASSAY FOR HELICOBACTER-PYLORI ANTIBODY DETECTION - CORRELATION WITH HISTOPATHOLOGICAL AND MICROBIOLOGICAL RESULTS
    PRONOVOST, AD
    ROSE, SL
    PAWLAK, JW
    ROBIN, H
    SCHNEIDER, R
    JOURNAL OF CLINICAL MICROBIOLOGY, 1994, 32 (01) : 46 - 50
  • [10] Evaluation of Immunoflourescence antibody assay for the detection of Enterocytozoon bieneusi and Encephalitozoon intestinalis
    Ghoshal, Ujjala
    Khanduja, Sonali
    Pant, Priyannk
    Ghoshal, Uday C.
    PARASITOLOGY RESEARCH, 2016, 115 (10) : 3709 - 3713