Reference-free Reduction of Ballistocardiogram Artifact from EEG Data Using EMD-PCA

被引:0
|
作者
Javed, Ehtasham [2 ]
Faye, Ibrahima [1 ]
Malik, Aamir Saeed [2 ]
Abdullah, Jafri Malin [3 ]
机构
[1] Univ Teknol PETRONAS, Dept Fundamental & Appl Sci, CISIR, Tronoh 31750, Perak, Malaysia
[2] Univ Teknol PETRONAS, Dept Elect & Elect Engn, CISIR, Tronoh 31750, Perak, Malaysia
[3] Hosp Univ Sains Malaysia, Sch Med Sci, Dept Neurosci, Kubang Kerian 16150, Kelantan, Malaysia
关键词
Simultaneous EEG-fMRI; Ballistocardiogram artifact; Empirical Mode Decomposition; Principal Component Analysis; Event-related potential; INDEPENDENT COMPONENT ANALYSIS; REMOVAL ALGORITHMS; FMRI; MRI; SUBTRACTION; RECORDINGS; EXTRACTION; EPILEPSY; SCANNER; MEMORY;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Concurrent electroencephalograph (EEG) and functional magnetic resonance image (fMRI) led researchers to acquire neuronal activities in detail over the past few decades. Regardless of the advantages of combining these modalities, artifacts posed a greater challenge to attain good quality data. One such problematic artifact which contaminates EEG recordings is Ballistocardiogram (BCG) artifact. A reference-free composite algorithm which combines empirical mode decomposition (EMD) and principal component analysis (PCA) named as EMD-PCA has been introduced in this study. The results show that the algorithm can efficiently reduce the BCG artifact by preserving original neuronal signals. The proposed algorithm showed improvement in reducing the BCG artifact as well as in the preservation of brain activities, when compared with two renowned existing methods that are average artifact subtraction (AAS) and optimal basis set (OBS).
引用
收藏
页数:6
相关论文
共 50 条
  • [1] An EMD based Method for Reduction of Ballistocardiogram Artifact from EEG Studies of Evoked Potentials
    Javed, Ehtasham
    Faye, Ibrahima
    Malik, Aamir Saeed
    Abdullah, Jafri Malin
    2015 IEEE 14TH INTERNATIONAL CONFERENCE ON MACHINE LEARNING AND APPLICATIONS (ICMLA), 2015, : 1199 - 1203
  • [2] A Hybrid Method to Improve the Reduction of Ballistocardiogram Artifact from EEG Data
    Javed, Ehtasham
    Faye, Ibrahima
    Malik, Aamir Saeed
    Abdullah, Jafri Malin
    NEURAL INFORMATION PROCESSING (ICONIP 2014), PT II, 2014, 8835 : 186 - 193
  • [3] Reference-free removal of EEG-fMRI ballistocardiogram artifacts with harmonic regression
    Krishnaswamy, Pavitra
    Bonmassar, Giorgio
    Poulsen, Catherine
    Pierce, Eric T.
    Purdon, Patrick L.
    Brown, Emery N.
    NEUROIMAGE, 2016, 128 : 398 - 412
  • [4] Reference-Free Harmonic Regression Technique to Remove EEG-fMRI Ballistocardiogram Artifacts
    Krishnaswamy, Pavitra
    Bonmassar, Giorgio
    Purdon, Patrick L.
    Brown, Emery N.
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 5426 - 5429
  • [5] Reduction of the ballistocardiogram artifact in simultaneous EEG-fMRI using ICA
    Huiskamp, G. J. M.
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 3691 - 3694
  • [6] Ballistocardiogram Artifact Reduction in Simultaneous EEG-fMRI Using Deep Learning
    McIntosh, James R.
    Yao, Jiaang
    Hong, Linbi
    Faller, Josef
    Sajda, Paul
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2021, 68 (01) : 78 - 89
  • [7] Reference-free phylogeny from sequencing data
    Rysavy, Petr
    Zelezny, Filip
    BIODATA MINING, 2023, 16 (01)
  • [8] Reference-free phylogeny from sequencing data
    Petr Ryšavý
    Filip Železný
    BioData Mining, 16
  • [9] SEGMENTATION OF EEG USING REFERENCE-FREE TOPOGRAPHICAL METHODS, AND THE SIGNIFICANCE OF EEG POWER MAPPED VS THE AVERAGE REFERENCE
    LEHMANN, D
    SKRANDIES, W
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1984, 57 (02): : P30 - P30
  • [10] Ballistocardiogram artifact removal from EEG signals using adaptive filtering of EOG signals
    In, Myung H.
    Lee, Soo Y.
    Park, Tae S.
    Kim, Tae-S
    Cho, Min H.
    Ahn, Young B.