Spectral measurements of light sources with a goniophotometer with and without mirror arrangement

被引:0
|
作者
Santos Gomes, Juliana Freitas [1 ]
Azara de Oliveira, Ivo Antonio [1 ]
Sardinha, Andre da Silva [1 ]
Viana, Domingos David [1 ]
Vieira, Rafaela Rezende [2 ]
Barbosa, Amanda Hang [2 ]
Dornelles de Alvarenga, Ana Paula [3 ]
机构
[1] Inmetro, Natl Inst Metrol Qual & Tecnol, Opt Metrol Div, Radiometry & Photometry Lab, Av Nossa Senhora Gracas 50, BR-25250020 Duque De Caxias, RJ, Brazil
[2] Univ Catolica Petropolis, Petropolis, Brazil
[3] Inmetro, Natl Inst Metrol Qual & Tecnol, Opt Metrol Div, Colorimetry & Spectrophotometry Lab, Rio De Janeiro, Brazil
关键词
D O I
10.1088/1742-6596/733/1/012025
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper presents a comparative study of the relative spectral radiance measurements of incandescent and LED light sources performed in two different setups with a rotating-mirror-goniophotometer. In one configuration the light is reflected by the goniophotometer mirror, while in the other the mirror is not used. This study permits to determine a spectral correction factor at each measured wavelength in order to obtain a more precise value for the Correlated Color Temperature (CCT) for any light sources with different spectral power distributions.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Goniophotometer for Measurements of Spectral Reflectance Coefficients and Transmission Spectra
    I. I. Bruchkouski
    V. A. Siliuk
    H. S. Litvinovich
    A. A. Lamaka
    V. V. Stanchuk
    S. I. Guliaeva
    Journal of Applied Spectroscopy, 2021, 88 : 363 - 369
  • [2] Goniophotometer for Measurements of Spectral Reflectance Coefficients and Transmission Spectra
    Bruchkouski, I. I.
    Siliuk, V. A.
    Litvinovich, H. S.
    Lamaka, A. A.
    Stanchuk, V. V.
    Guliaeva, S., I
    JOURNAL OF APPLIED SPECTROSCOPY, 2021, 88 (02) : 363 - 369
  • [3] SPECTRAL RAY TRACING FROM NEAR FIELD GONIOPHOTOMETER MEASUREMENTS
    Rykowski, Ronald
    PROCEEDINGS OF THE CIE EXPERT SYMPOSIUM ON SPECTRAL AND IMAGING METHODS FOR PHOTOMETRY AND RADIOMETRY, 2010, : 1 - 8
  • [4] SPECTRAL RAY TRACING FROM NEAR FIELD GONIOPHOTOMETER MEASUREMENTS
    Rykowski, Ronald
    LIGHT & ENGINEERING, 2011, 19 (01): : 23 - 29
  • [5] Raster-type Goniophotometer for Light Measurements at Small Distances.
    Petrov, V.M.
    Svetotehnika, 1984, (03): : 10 - 12
  • [6] STRAY LIGHT MEASUREMENT WITH SOLID STATE LIGHT LUMINAIRE IN A C-TYPE GONIOPHOTOMETER WITH ROTATING MIRROR
    Velasquez, C.
    Espin, F.
    Arteaga, J.
    PROCEEDINGS OF CIE 2016 LIGHTING QUALITY AND ENERGY EFFICIENCY, 2016, : 753 - 761
  • [7] Measurements of Inclination Angle and Distance of Curved Mirror Using LED Light Sources
    Nishibori, Kento
    Nishibori, Kenji
    38TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2012), 2012, : 2601 - 2606
  • [8] Light sources and light measurements
    Shirley, HL
    PLANT PHYSIOLOGY, 1931, 6 (03) : 447 - 466
  • [9] MEASUREMENTS OF LIGHT-SCATTERING IN NORMAL PORK USING A FIBER-OPTIC GONIOPHOTOMETER
    SWATLAND, HJ
    JOURNAL OF ANIMAL SCIENCE, 1988, 66 (10) : 2578 - 2582
  • [10] MODIFICATION OF A BECKMAN SPECTROPHOTOMETER FOR DIRECT MEASUREMENTS OF SPECTRAL ENERGY DISTRIBUTION OF LIGHT SOURCES
    GRUM, F
    APPLIED OPTICS, 1963, 2 (03): : 237 - 242