A new LAMP-based assay for the molecular diagnosis of toxoplasmosis: comparison with a proficient PCR assay

被引:8
|
作者
Varlet-Marie, Emmanuelle [1 ,2 ,3 ]
Sterkers, Yvon [1 ,2 ]
Perrotte, Marina [4 ]
Bastien, Patrick [1 ,2 ]
机构
[1] Univ Montpellier, CHU Univ Hosp Ctr Montpellier, Lab Parasitol Mycol, Res Unit MIVEGEC,CNRS,IRD,Fac Med, Montpellier, France
[2] Pole Biol Mol Ctr Natl Reference Toxoplasmose, Montpellier, France
[3] Univ Montpellier, Fac Pharm, Lab Biophys & Bioanal, Montpellier, France
[4] DiaSorin SA France, F-92160 Antony, France
关键词
Toxoplasma gondii; Diagnosis; PCR; LAMP; Commercial kit; POLYMERASE-CHAIN-REACTION; CONGENITAL TOXOPLASMOSIS; GONDII; TIME; INFECTION; EVOLUTION; KIT;
D O I
10.1016/j.ijpara.2017.11.005
中图分类号
R38 [医学寄生虫学]; Q [生物科学];
学科分类号
07 ; 0710 ; 09 ; 100103 ;
摘要
Toxoplasmosis is generally a benign infection caused by the protozoan parasite Toxoplasma gondii but can have severe consequences in fetuses of mothers infected during pregnancy (congenital toxoplasmosis) and immunocompromised individuals. PCR-based diagnostic tests have become crucial for its diagnosis. However, this molecular diagnosis essentially relies upon laboratory-developed methods and suffers from a lack of standardization, leading to great variation in methods and performance among laboratories. With the need for accreditation of clinical microbiological laboratories, the use of commercial PCR kits has become an attractive alternative; but thorough evaluation of newly commercialized kits by proficient groups is necessary before any recommendation can be made to parasitology laboratories by health authorities or learned societies. Here, we compared the performance of an original commercial method, the lam TOXO Q-LAMP (DiaSorin (R)), using Loop-mediated isothermal amplification (LAMP) technology, with our reference laboratory-developed method using real-time PCR. The kit was first tested using amniotic fluid (AF) and plasma samples (either negative or spiked with live T. gondii tachyzoites at different concentrations (from 7 to 10 5 tachyzoites/mL)). It was then assessed using a cohort of 11 AF, five placental and 32 blood clinical samples preserved at -20 degrees C. For the processing of placental/blood samples, a pretreatment step was used, which did not strictly follow the manufacturer's recommendations. The practical ease of use and compliance with good laboratory practices were also evaluated. Although the LAMP assay was less sensitive than the laboratory-developed method at very low parasite concentrations (0.1 T. gondii genome equivalents/mL), the two methods yielded identical results qualitatively and, in some instances, quantitatively, particularly for AF samples. (C) 2018 Published by Elsevier Ltd on behalf of Australian Society for Parasitology.
引用
收藏
页码:457 / 462
页数:6
相关论文
共 50 条
  • [1] A LAMP-based assay for the molecular detection of group B Streptococcus.
    Lemaire, Coralie
    Cheminet, Melinda
    Duployez, Claire
    Artus, Mathilde
    Ballaa, Yassine
    Devos, Laura
    Plainvert, Celine
    Poyart, Claire
    Le Gall, Florence
    Tazi, Asmaa
    Lanotte, Philippe
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2023, 42 (10) : 1245 - 1250
  • [2] A LAMP-based assay for the molecular detection of group B Streptococcus.
    Coralie Lemaire
    Mélinda Cheminet
    Claire Duployez
    Mathilde Artus
    Yassine Ballaa
    Laura Devos
    Céline Plainvert
    Claire Poyart
    Florence Le Gall
    Asmaa Tazi
    Philippe Lanotte
    European Journal of Clinical Microbiology & Infectious Diseases, 2023, 42 : 1245 - 1250
  • [3] CONTRIBUTION OF A NEW PCR ASSAY TO THE PRENATAL-DIAGNOSIS OF CONGENITAL TOXOPLASMOSIS
    CAZENAVE, J
    FORESTIER, F
    BESSIERES, MH
    BROUSSIN, B
    BEGUERET, J
    PRENATAL DIAGNOSIS, 1992, 12 (02) : 119 - 127
  • [4] COMPARISON BETWEEN A NOVEL COMMERCIAL ASSAY BASED ON LOOP MEDIATED ISOTHERMAL AMPLIFICATION (LAMP) AND PCR-NESTED ASSAY FOR MOLECULAR DIAGNOSIS OF PLASMODIUM PARASITES
    Menegon, Michela
    L'Episcopia, Mariangela
    Boccolini, Daniela
    Paglia, Maria Grazia
    Gradoni, Luigi
    Severini, Carlo
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2017, 95 (05): : 87 - 87
  • [5] LAMP-based assay can rectify the diagnosis of Yersinia pseudotuberculosis infections otherwise missed by serology
    Kato, Atsushi
    Miyata, Ippei
    Tanaka, Yuhei
    Oishi, Tomohiro
    Teranishi, Hideto
    Akaike, Hiroto
    Ohno, Naoki
    Nakajima, Hiroshi
    Kouguchi, Yutaka
    Ouchi, Kazunobu
    JOURNAL OF MEDICAL MICROBIOLOGY, 2019, 68 (02) : 143 - 147
  • [6] Electrochemical LAMP-based assay for detection of RNA biomarkers in prostate cancer
    Moranova, Ludmila
    Stanik, Michal
    Hrstka, Roman
    Campuzano, Susana
    Bartosik, Martin
    TALANTA, 2022, 238
  • [7] Comparison of B1 and RE 529 gene targets by real time PCR and LAMP assay for diagnosis of toxoplasmosis in pregnant females
    Datta, Priya
    Garg, Puja
    Rattan, Divya
    Bagga, Rashmi
    Rohilla, Minakshi
    Khurana, Sumeeta
    Sehgal, Rakesh
    INDIAN JOURNAL OF MEDICAL MICROBIOLOGY, 2024, 47
  • [8] Comparison of PneumID real-time PCR assay with Amplex eazyplex LAMP assay for laboratory diagnosis of Pneumocystis jirovecii Pneumonia
    Ng, Willy W. Y.
    Ho, Yolanda I. I.
    Wong, Ann H.
    Leung, Eddie C. M.
    Lee, Alfred L. H.
    Chow, Viola C. Y.
    MEDICAL MYCOLOGY, 2022, 60 (06)
  • [9] Comparison of histopathology and PCR based assay for detection of experimentally induced toxoplasmosis in murine model
    Vikrant Sudan
    A.K.Tewari
    R Singh
    Harkirat Singh
    Asian Pacific Journal of Tropical Medicine, 2015, (06) : 448 - 451
  • [10] Comparison of histopathology and PCR based assay for detection of experimentally induced toxoplasmosis in murine model
    Sudan, Vikrant
    Tewari, A. K.
    Singh, R.
    Singh, Harkirat
    ASIAN PACIFIC JOURNAL OF TROPICAL MEDICINE, 2015, 8 (06) : 448 - 451