Fabrication and characterization of large numerical aperture, high-resolution optical fiber bundles based on high-contrast pairs of soft glasses for fluorescence imaging

被引:18
|
作者
Morova, B. [1 ]
Bavili, N. [1 ]
Yaman, O. [1 ]
Yigit, B. [2 ]
Zeybel, M. [2 ]
Aydin, M. [3 ]
Dogan, B. [4 ]
Kasztelanic, R. [5 ]
Pysz, D. [5 ]
Buczynski, R. [5 ,6 ]
Kiraz, A. [1 ,7 ]
机构
[1] Koc Univ, Dept Phys, TR-34450 Istanbul, Turkey
[2] Koc Univ, Sch Med, Dept Gastroenterol & Hepatol, TR-34450 Istanbul, Turkey
[3] Fatih Sultan Mehmet Vakif Univ, Dept Comp Engn, TR-34445 Istanbul, Turkey
[4] Marmara Univ, Dept Comp Engn, TR-34730 Istanbul, Turkey
[5] Inst Elect Mat Technol, Dept Glass, Wolczynska 133, PL-01919 Warsaw, Poland
[6] Univ Warsaw, Fac Phys, Pasteura 5, PL-02093 Warsaw, Poland
[7] Koc Univ, Dept Elect & Elect Engn, TR-34450 Istanbul, Turkey
基金
欧盟地平线“2020”;
关键词
IN-VIVO; CONFOCAL MICROSCOPY; 2-PHOTON MICROSCOPE; SINGLE-FIBER; DEEP BRAIN; ENDOMICROSCOPY; ENDOSCOPY; PROBE; HEAD;
D O I
10.1364/OE.27.009502
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Fabrication and characterization of flexible optical fiber bundles (FBs) with in-house synthesized high-index and low-index thermally matched glasses are presented. The FBs composed of around 15000 single-core fibers with pixel sizes between 1.1 and 10 mu m are fabricated using the stack-and-draw technique from sets of thermally matched zirconium-silicate ZR3, borosilicate SK222, sodium-silicate K209, and F2 glasses. With high refractive index contrast pair of glasses ZR3/SK222 and K209/F2, FBs with numerical apertures (NAs) of 0.53 and 0.59 are obtained, respectively. Among the studied glass materials, ZR3, SK222, and K209 are in-house synthesized, while F2 is commercially acquired. Seven different FBs with varying pixel sizes and bundle diameters are characterized. Brightfield imaging of a micro-ruler and a Convallaria majalis sample and fluorescence imaging of a dye-stained paper tissue and a cirrhotic mice liver tissue are demonstrated using these FBs. demonstrating their good potential for microendoscopic imaging. Brightfield and fluorescence imaging performance of the studied FBs are compared. For both sets of glass compositions, good imaging performance is observed for FBs, with core diameter and core-to-core distance values larger than 1.6 mu m and 2.3 mu m, respectively. FBs fabricated with K209/F2 glass pairs revealed better performance in fluorescence imaging due to their higher NA of 0.59. (C) 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:9502 / 9515
页数:14
相关论文
共 24 条
  • [1] High-contrast lead-free pair of soft glasses for large numerical aperture imaging bundles
    Stepien, Ryszard
    Cimek, Jaroslaw
    Pysz, Dariusz
    Kujawa, Ireneusz
    Golebiewski, Przemyslaw
    Stepniewski, Grzegorz
    Orlinski, Krzysztof
    Buczynski, Ryszard
    Kasztelanic, Rafal
    OPTICAL MATERIALS EXPRESS, 2020, 10 (08): : 1891 - 1910
  • [2] Analysis and characterization of high-resolution and high-aspect-ratio imaging fiber bundles
    Motamedi, Nojan
    Karbasi, Salman
    Ford, Joseph E.
    Lomakin, Vitaliy
    APPLIED OPTICS, 2015, 54 (32) : 9422 - 9431
  • [3] A system for high-resolution depth-resolved optical imaging of fluorescence and absorption contrast
    Yuan, Baohong
    Burgess, Sean A.
    Iranmahboob, Amir
    Bouchard, Matthew B.
    Lehrer, Nicole
    Bordier, Clemence
    Hillman, Elizabeth M. C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (04):
  • [4] Simple approach for high-contrast optical imaging and characterization of graphene-based sheets
    Jung, Inhwa
    Pelton, Matthew
    Piner, Richard
    Dikin, Dmitriy A.
    Stankovich, Sasha
    Watcharotone, Supinda
    Hausner, Martina
    Ruoff, Rodney S.
    NANO LETTERS, 2007, 7 (12) : 3569 - 3575
  • [5] High-Contrast Fluorescence Imaging Based on the Polarization Dependence of the Fluorescence Enhancement Using an Optical Interference Mirror Slide
    Yasuda, Mitsuru
    Akimoto, Takuo
    ANALYTICAL SCIENCES, 2015, 31 (03) : 139 - 143
  • [6] High-Contrast Fluorescence Imaging Based on the Polarization Dependence of the Fluorescence Enhancement Using an Optical Interference Mirror Slide
    Mitsuru Yasuda
    Takuo Akimoto
    Analytical Sciences, 2015, 31 : 139 - 143
  • [7] Design and fabrication of a fiber optic image inverter based on a new high numerical aperture fiber optic glasses system
    Pan Jingsheng
    Lv Jingwen
    Zheng Tao
    Liu Wenwei
    Xu Wei
    Sun Jianning
    Su Detan
    OPTOELECTRONIC IMAGING AND MULTIMEDIA TECHNOLOGY, 2010, 7850
  • [8] High-resolution imaging techniques based on optical synthetic aperture - art. no. 672103
    Wang, Shengqian
    Rao, Changhui
    Jiang, Wenhan
    Song, Helun
    3RD INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: LARGE MIRRORS AND TELESCOPES, 2007, 6721 : 72103 - 72103
  • [9] Super-resolution optical microscopic imaging method based on annular illumination with high numerical aperture
    Zhi Shao-Tao
    Zhang Hai-Jun
    Zhang Dong-Xian
    ACTA PHYSICA SINICA, 2012, 61 (02)
  • [10] Fast optical high-resolution imaging through scattering medium based on virtual synthetic aperture model
    Qiao, Kai
    Tian, Xiaorui
    Shi, Xiaojie
    Yang, Jie
    Tang, Meng
    Zhang, Siqi
    Jin, Chenfei
    OPTICS AND LASER TECHNOLOGY, 2025, 181