Inter-Observer, Intra-Observer and Intra-Individual Reliability of Uroflowmetry Tests in Aged Men: A Generalizability Theory Approach

被引:6
|
作者
Liu, Ying-Buh
Yang, Stephen S.
Hsieh, Cheng-Hsing
Lin, Chia-Da
Chang, Shang-Jen [1 ]
机构
[1] Buddhist Tzu Chi Gen Hosp, Div Urol, Taipei Branch, Taipei 231, Taiwan
关键词
intra-individual reliability; inter-observer reliability; uroflowmetry; intra-observer reliability; GUIDELINES; CURVES;
D O I
10.1111/luts.12022
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objectives To evaluate the inter-observer, intra-observer and intra-individual reliability of uroflowmetry and post-void residual urine (PVR) tests in adult men. Methods Healthy volunteers aged over 40 years were enrolled. Every participant underwent two sets of uroflowmetry and PVR tests with a 2-week interval between the tests. The uroflowmetry tests were interpreted by four urologists independently. Uroflowmetry curves were classified as bell-shaped, bell-shaped with tail, obstructive, restrictive, staccato, interrupted and tower-shaped and scored from 1 (highly abnormal) to 5 (absolutely normal). The agreements between the observers, interpretations and tests within individuals were analyzed using kappa statistics and intraclass correlation coefficients. Generalizability theory with decision analysis was used to determine how many observers, tests, and interpretations were needed to obtain an acceptable reliability (> 0.80). Results Of 108 volunteers, we randomly selected the uroflowmetry results from 25 participants for the evaluation of reliability. The mean age of the studied adults was 55.3 years. The intra-individual and intra-observer reliability on uroflowmetry tests ranged from good to very good. However, the inter-observer reliability on normalcy and specific type of flow pattern were relatively lower. In generalizability theory, three observers were needed to obtain an acceptable reliability on normalcy of uroflow pattern if the patient underwent uroflowmetry tests twice with one observation. Conclusions The intra-individual and intra-observer reliability on uroflowmetry tests were good while the inter-observer reliability was relatively lower. To improve inter-observer reliability, the definition of uroflowmetry should be clarified by the International Continence Society.
引用
收藏
页码:76 / 80
页数:5
相关论文
共 50 条
  • [41] An inter-observer and intra-observer study of a classification of RetCam images of retinal haemorrhages in children
    Mulvihill, Alan O.
    Jones, Patricia
    Tandon, Anamika
    Fleck, Brian W.
    Minns, Robert A.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (01) : 99 - 104
  • [42] INTRA-OBSERVER AND DEVICE-DEPENDENT INTER-OBSERVER RELIABILITY OF CONTRAST-ENHANCED ULTRASOUND FOR MUSCLE PERFUSION QUANTIFICATION
    Kunz, Pierre
    Kiesl, Sophia
    Gro, Sascha
    Kauczor, Hans-Ulrich
    Schmidmaier, Gerhard
    Fischer, Christian
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (02): : 275 - 285
  • [43] Inter-observer and intra-observer reliability for lung cancer target volume delineation in the 4D-CT era
    Rodrigues, George
    Louie, Alexander
    Olsthoorn, Jason
    Palma, David
    Yu, Edward
    Yaremko, Brian
    Ahmad, Belal
    Aivas, Inge
    Gaede, Stewart
    JOURNAL OF THORACIC ONCOLOGY, 2009, 4 (09) : S532 - S533
  • [44] Inter-observer and intra-observer reliability for lung cancer target volume delineation in the 4D-CT era
    Louie, Alexander V.
    Rodrigues, George
    Olsthoorn, Jason
    Palma, David
    Yu, Edward
    Yaremko, Brian
    Ahmad, Bela
    Aivas, Inge
    Gaede, Stewart
    RADIOTHERAPY AND ONCOLOGY, 2010, 95 (02) : 166 - 171
  • [45] Inter-observer and Intra-observer Reliability for Lung Cancer Target Volume Delineation in the 4D-CT Era
    Louie, A. V.
    Rodrigues, G.
    Olsthoorn, J.
    Palma, D.
    Yu, E.
    Yaremko, B.
    Ahmad, B.
    Aivas, I.
    Gaede, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S472 - S473
  • [46] How reliable is the pathologist's diagnosis of endometriosis: a prospective inter-observer and intra-observer analysis
    Hurtado, Rodrigo
    Geber, Selmo
    JOURNAL OF ENDOMETRIOSIS AND PELVIC PAIN DISORDERS, 2012, 4 (01) : 30 - 33
  • [47] Measurement of high resolution ultrasound images: Intra-observer and inter-observer reliablity and image reproducibility
    Bentley, E
    Diehl, KA
    Miller, PE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U286 - U286
  • [48] THE REDUCTION OF INTER-OBSERVER AND INTRA-OBSERVER VARIABILITY FOR DEFINING REGIONS OF INTEREST IN NUCLEAR-MEDICINE
    JACKSON, PC
    JONES, M
    BRIMBLE, CE
    HART, J
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1985, 11 (05): : 186 - 189
  • [49] Inter- and intra-observer reliability of clinical movement-control tests for marines
    Andreas Monnier
    Joachim Heuer
    Kjell Norman
    Björn O Äng
    BMC Musculoskeletal Disorders, 13
  • [50] Intra-observer and inter-observer repeatability of ocular surface interferometer in measuring lipid layer thickness
    Yang Zhao
    Carin Lay San Tan
    Louis Tong
    BMC Ophthalmology, 15