Inter-Observer, Intra-Observer and Intra-Individual Reliability of Uroflowmetry Tests in Aged Men: A Generalizability Theory Approach

被引:6
|
作者
Liu, Ying-Buh
Yang, Stephen S.
Hsieh, Cheng-Hsing
Lin, Chia-Da
Chang, Shang-Jen [1 ]
机构
[1] Buddhist Tzu Chi Gen Hosp, Div Urol, Taipei Branch, Taipei 231, Taiwan
关键词
intra-individual reliability; inter-observer reliability; uroflowmetry; intra-observer reliability; GUIDELINES; CURVES;
D O I
10.1111/luts.12022
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objectives To evaluate the inter-observer, intra-observer and intra-individual reliability of uroflowmetry and post-void residual urine (PVR) tests in adult men. Methods Healthy volunteers aged over 40 years were enrolled. Every participant underwent two sets of uroflowmetry and PVR tests with a 2-week interval between the tests. The uroflowmetry tests were interpreted by four urologists independently. Uroflowmetry curves were classified as bell-shaped, bell-shaped with tail, obstructive, restrictive, staccato, interrupted and tower-shaped and scored from 1 (highly abnormal) to 5 (absolutely normal). The agreements between the observers, interpretations and tests within individuals were analyzed using kappa statistics and intraclass correlation coefficients. Generalizability theory with decision analysis was used to determine how many observers, tests, and interpretations were needed to obtain an acceptable reliability (> 0.80). Results Of 108 volunteers, we randomly selected the uroflowmetry results from 25 participants for the evaluation of reliability. The mean age of the studied adults was 55.3 years. The intra-individual and intra-observer reliability on uroflowmetry tests ranged from good to very good. However, the inter-observer reliability on normalcy and specific type of flow pattern were relatively lower. In generalizability theory, three observers were needed to obtain an acceptable reliability on normalcy of uroflow pattern if the patient underwent uroflowmetry tests twice with one observation. Conclusions The intra-individual and intra-observer reliability on uroflowmetry tests were good while the inter-observer reliability was relatively lower. To improve inter-observer reliability, the definition of uroflowmetry should be clarified by the International Continence Society.
引用
收藏
页码:76 / 80
页数:5
相关论文
共 50 条
  • [31] Visual diagnosis of pectus excavatum: An inter-observer and intra-observer agreement analysis
    Daemen, Jean H. T.
    de Loos, Erik R.
    Geraedts, Tessa C. M.
    van Veer, Hans
    Van Huijstee, Pieter Jan
    Elenbaas, Ted W. O.
    Hulsewe, Karel W. E.
    Vissers, Yvonne L. J.
    JOURNAL OF PEDIATRIC SURGERY, 2022, 57 (03) : 526 - 531
  • [32] Intra-observer and inter-observer variation in the histopathological assessment of chronic viral hepatitis
    Goldin, RD
    Goldin, JG
    Burt, AD
    Dhillon, PA
    Hubscher, S
    Wyatt, J
    Patel, N
    JOURNAL OF HEPATOLOGY, 1996, 25 (05) : 649 - 654
  • [33] Inter-observer and intra-observer agreement in diagnosis of type 2 brugada pattern
    Crea, Pasquale
    Rivetti, Luigi
    Bitto, Roberto
    Zappia, Luca
    Caracciolo, Alessandro
    Scalise, Renato
    Salito, Armando
    Mazzone, Paolo
    Pellegrino, Nicolo
    Ruggieri, Chiara
    Frecentese, Francesca
    Croella, Francesca
    Dattilo, Giuseppe
    Luzza, Francesco
    Oreto, Giuseppe
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2019, 21 (0J) : J11 - J11
  • [34] An evaluation of the inter-observer and intra-observer variability of the ultrasound diagnosis of polycystic ovaries
    Amer, SAKS
    Li, TC
    Bygrave, C
    Sprigg, A
    Saravelos, H
    Cooke, ID
    HUMAN REPRODUCTION, 2002, 17 (06) : 1616 - 1622
  • [35] Intra-Observer and Inter-Observer Reliability of Ankle Circumference Measurement in Patients with Diabetic Foot: A Prospective Observational Study
    Montoro-Cremades, David
    Tardaguila-Garcia, Aroa
    Navarro-Perez, David
    Garcia-Alvarez, Yolanda
    Lopez-Moral, Mateo
    Lazaro-Martinez, Jose Luis
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (22)
  • [36] Bosniak classification system: inter-observer and intra-observer agreement among experienced uroradiologists
    Graumann, Ole
    Osther, Susanne S.
    Karstoft, Jens
    Horiyck, Arne
    Osther, Palle J. S.
    ACTA RADIOLOGICA, 2015, 56 (03) : 374 - 383
  • [37] Inter-Observer and Intra-Observer Variations in the Assessment of Epithelial Dysplasia in Oral Lichenoid Diseases
    Zohdy, Marwa
    Cazzaniga, Simone
    Nievergelt, Helga
    Blum, Roland
    Suter, Valerie G. A.
    Feldmeyer, Laurence
    Beltraminelli, Helmut
    DERMATOPATHOLOGY, 2021, 8 (02): : 84 - 88
  • [38] Inter-observer and Intra-observer Variability in Volume Measurements of the Lower Extremity Using Perometer
    Reza, Carni
    Norregaard, Susan
    Moffatt, Christine
    Karlsmark, Tonny
    LYMPHATIC RESEARCH AND BIOLOGY, 2020, 18 (05) : 416 - 421
  • [39] INTER-OBSERVER AND INTRA-OBSERVER VARIABILITY OF THE OXFORD CLINICAL CATARACT CLASSIFICATION AND GRADING SYSTEM
    SPARROW, JM
    AYLIFFE, W
    BRON, AJ
    BROWN, NP
    HILL, AR
    INTERNATIONAL OPHTHALMOLOGY, 1988, 11 (03) : 151 - 157
  • [40] Inter-observer and intra-observer error in assessment of heterotopic ossification in intramedullary nailing of the femur
    Wilson, S.
    Jain, N.
    Finnigan, T.
    Zubairy, A.
    BRITISH JOURNAL OF SURGERY, 2017, 104 : 32 - 32