Safety and efficacy of the Derivo Embolization Device for the treatment of ruptured intracranial aneurysms

被引:35
|
作者
Goertz, Lukas [1 ]
Dorn, Franziska [2 ]
Kraus, Bastian [3 ]
Borggrefe, Jan [4 ]
Schlamann, Marc [4 ]
Forbrig, Robert [2 ]
Turowski, Bernd [3 ]
Kabbasch, Christoph [4 ]
机构
[1] Univ Hosp Cologne, Ctr Neurosurg, D-50937 Cologne, Germany
[2] Univ Hosp Munich LMU, Dept Neuroradiol, Munich, Germany
[3] Univ Hosp Duesseldorf, Dept Neuroradiol, Dusseldorf, Germany
[4] Univ Hosp Cologne, Dept Neuroradiol, Cologne, Germany
关键词
FLOW-DIVERTOR; DIVERSION; COILING; COMPLICATIONS;
D O I
10.1136/neurintsurg-2018-014166
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Background The Derivo Embolization Device (DED) is a novel flow diverter with advanced X-ray visibility, potentially lower thrombogenicity, and an improved delivery system. Objective To evaluate the safety and efficacy of the DED for emergency treatment of ruptured intracranial aneurysms. Methods Between February 2016 and March 2018, 10 patients (median age 54.5 years, seven women) with 11 aneurysms were treated with the DED at three neurovascular centers. Procedural details, complications, morbidity, and aneurysm occlusion (O'Kelly-Marotta scale, OKM) were retrospectively reviewed. Results A mong 11 aneurysms treated, there were nine anterior circulation and two posterior circulation aneurysms. Aneurysm morphology was saccular in four cases, dissecting in three, blister-like in three, and fusiform in one. In each case, a single DED was implanted and deployment was technically successful without exception. Adjunctive coiling was performed in two aneurysms. We observed one in-stent thrombosis, presumably due to low response to clopidogrel 4 days after the procedure, which remained with a mild hemiparesis after aspiration thrombectomy. No further thromboembolic or hemorrhagic events occurred. Favorable outcome (modified Rankin scale score >= 2) at last follow-up was achieved in all patients. Among 10 aneurysms available for angiographic follow-up, complete aneurysm occlusion (OKM D) was obtained in nine cases (90.0%). Conclusions I n this pilot study, endovascular treatment of ruptured intracranial aneurysms with the DED was feasible and not associated with any incidence of rebleeding. Larger series with longer follow-up are warranted to reach a definite conclusion about this device.
引用
收藏
页码:290 / +
页数:7
相关论文
共 50 条
  • [1] Safety and efficacy of the Derivo Embolization Device for the treatment of unruptured intracranial aneurysms: a multicentric study
    Kraus, Bastian
    Goertz, Lukas
    Turowski, Bernd
    Borggrefe, Jan
    Schlamann, Marc
    Dorn, Franziska
    Kabbasch, Christoph
    [J]. JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2019, 11 (01) : 68 - 73
  • [2] The DERIVO®2 Embolization Device in the treatment of ruptured and unruptured intracranial aneurysms: A multicenter analysis
    Thormann, Maximilian
    Sillis, Nele
    Thoma, Taina
    Altenbernd, Jens
    Berger, Bjoern
    Cioltan, Andrea
    Loehr, Christian
    Bohner, Georg
    Siebert, Eberhard
    Nordmeyer, Hannes
    Mpotsaris, Anastasios
    Behme, Daniel
    [J]. INTERVENTIONAL NEURORADIOLOGY, 2022,
  • [3] The DERIVO 2 Heal Embolization Device in the Treatment of Ruptured and Unruptured Intracranial Aneurysms: a Retrospective Multicenter Study
    Schwab, Roland
    Kabbasch, Christoph
    Goertz, Lukas
    Kaschner, Marius
    Weiss, Daniel
    Loehr, Christian
    Wensing, Hauke
    Bester, Maxim
    Simgen, Andreas
    Kemmling, Andre
    Wendl, Christina
    Fuchs, Erelle
    Thormann, Maximilian
    Behme, Daniel
    Nordmeyer, Hannes
    [J]. CLINICAL NEURORADIOLOGY, 2024,
  • [4] Derivo Embolization Device for the Treatment of Intracranial Aneurysms A Multicenter Study of 183 Aneurysms
    Trivelato, Felipe Padovani
    Abud, Daniel Giansante
    Ulhoa, Alexandre Cordeiro
    Waihrich, Eduardo Siqueira
    Abud, Thiago Giansante
    Castro Afonso, Luis Henrique
    Nakiri, Guilherme Seizem
    de Castro, Guilherme Duarte
    Mendes Parente, Bruno de Sousa
    Silva, Rodrigo dos Santos
    Manzato, Luciano Bambini
    Bonadio, Lucas Eduardo
    Viana, Dinark Conceicao
    Vanzin, Jose Ricardo
    Baccin, Carlos Eduardo
    Salles Rezende, Marco Tulio
    [J]. STROKE, 2019, 50 (09) : 2351 - 2358
  • [5] Endovascular treatment of intracranial aneurysms using the Derivo Embolization Device: a multicenter experience
    Lourenco, Galileu Chagas
    Dantas, Francois
    Carvalho, Tiago Silva E.
    Rodrigues Firmino, Roberti Uili
    Filgueiras Filho, Marcelo Quesado
    Tosello, Renato Tavares
    Leao, Claudio Jose
    Piske, Ronie Leo
    Darwich, Rogerio Zenobio
    [J]. JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2023, 15 (08) : 776 - 780
  • [6] Treatment of Ruptured Intracranial Aneurysms With the Pipeline Embolization Device
    Chalouhi, Nohra
    Zanaty, Mario
    Whiting, Alex
    Tjoumakaris, Stavropoula
    Hasan, David
    Ajiboye, Norman
    Hann, Shannon
    Rosenwasser, Robert H.
    Jabbour, Pascal
    [J]. NEUROSURGERY, 2015, 76 (02) : 165 - 172
  • [7] Derivo embolization device in the treatment of unruptured intracranial aneurysms: a prospective multicenter study
    Taschner, Christian A.
    Stracke, Christian Paul
    Dorn, Franziska
    Kadziolka, Krzysztof Bartosz
    Kreiser, Kornelia
    Solymosi, Laszlo
    Pham, Mirko
    Buhk, Jan Hendrik
    Turowski, Bernd
    Reith, Wolfgang
    Elsheikh, Samer
    Meckel, Stephan
    Janssen, Hendrik
    Hammer, Alexander
    Beuing, Oliver
    Jansen, Olav
    Urbach, Horst
    Knauth, Michael
    Jenkner, Carolin
    Chapot, Rene
    [J]. JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2021, 13 (06) : 541 - 546
  • [8] The DERIVO Embolization Device in the Treatment of Intracranial Aneurysms: Short- and Midterm Results
    Akgul, Erol
    Onan, Hasan Bilen
    Akpinar, Suha
    Balli, Huseyin Tugsan
    Aksungur, Erol Huseyin
    [J]. WORLD NEUROSURGERY, 2016, 95 : 229 - 240
  • [9] Efficacy and Safety of Treatment of Ruptured Intracranial Aneurysms
    Hammer, Alexander
    Steiner, Anahi
    Kerry, Ghassan
    Ranaie, Gholamreza
    Yakubov, Eduard
    Lichtenstern, David
    Baer, Ingrid
    Hammer, Christian M.
    Kunze, Stefan
    Steiner, Hans-Herbert
    [J]. WORLD NEUROSURGERY, 2017, 98 : 780 - 789
  • [10] Derivo embolization device for intracranial aneurysms: a Spanish multicenter retrospective study
    Pinana, Carlos
    Remollo, Sebastian
    Zamarro, Joaquin
    Werner, Mariano
    Espinosa de Rueda, Mariano
    Vega, Pedro
    Hernandez, David
    Murias, Eduardo
    Rivera, Eila
    Olier, Jorge
    San Roman, Luis
    Paez-Carpio, Alfredo
    Requena, Manuel
    Aixut, Sonia
    de Dios Lascuevas, Marta
    Moreu, Manuel
    Rosati, Santiago
    Gramegna, Laura Ludovica
    Castano, Carlos
    Tomasello, Alejandro
    [J]. JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2023, 15 (09) : 871 - 875