Effects of Supporting Systems During Cardiopulmonary Resuscitation: a Prospective Simulation Study to Evaluate Metronome and Real-Time Feedback

被引:4
|
作者
Gude, P. [1 ]
Lukas, R. P. [2 ]
Weber, T. P. [1 ]
Wecker, S. [3 ]
Bohn, A. [4 ]
机构
[1] Klinikum Ruhr Univ Bochum, St Josef Hosp, Klin Anasthesiol & Intens Med, Bochum, Germany
[2] Univ Klin Munster, Klin Anasthesiol Operat Intens Med & Schmerzthera, Munster, Germany
[3] Feuerwehrarztlicher Dienst, Feuerwehr, Stadt Paderborn, Paderborn, Germany
[4] Arztliche Leitung Rettungsdienst, Feuerwehr, Stadt Munster, Munster, Germany
来源
NOTARZT | 2016年 / 32卷 / 06期
关键词
cardiopulmonary resuscitation; real-time feedback; metronome; attention; HOSPITAL CARDIAC-ARREST; BASIC LIFE-SUPPORT; AUDIOVISUAL FEEDBACK; CHEST COMPRESSIONS; COUNCIL GUIDELINES; QUALITY; CPR; SURVIVAL; IMPACT;
D O I
10.1055/s-0042-110688
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Chest compression is an essential component of cardiopulmonary resuscitation (CPR), and influences survival of cardiac arrest victims. Adherence to guideline and chest compression quality differ widely. The medical industry as well as software engineers has developed technical support (e.g. metronome and real-time feedback) to improve chest compression quality. However, which elements of real-time feedback devices best assist rescuers remain unclear. We hypothesized that only a combination of metronome and audio-visual real-time feedback and not a stand-alone metronome improves chest compression quality. In this prospective manikin study, 100 emergency medical technicians were randomly assigned to 50 teams and performed CPR in three simulated cardiac arrest scenarios. Scenario A without any technical support during CPR was the control situation. In scenario B, there was support from a stand-alone metronome (100/min). In scenario C, the team was supported by a metronome (100/min) and audio-visual real-time feedback on chest compression depth. Endpoints in each 10-minute simulation were chest compression rate, correct chest compressions (defined as correct hand position, depth, recoil in a minimum of 70%), mean ventilation rate and tidal volume. There were differences in the mean compression rate (Scenario A 118 +/- 14cc/min; Scenario B 101 +/- 4cc/min; Scenario C 101 +/- 2cc/min; B and C vs. A; p<0.05) as well as in correct chest compression (A 40% correct; B 38% correct; C 92% correct compressions; A and B vs. C, P<0.05). We found no differences in ventilation. As in previous studies, in the CPR scenarios without any technical support, chest compressions were carried out too fast and were too shallow compared with the guidelines. A stand-alone metronome improved chest compression rate but diminished chest compression depth significantly. The combination of a metronome and audio-visual feedback improved both chest compression rate and depth. A feedback-system has to take human abilities of signal perception and processing into account. A metronome can distract the rescuer from other quality characteristics of chest compressions. This study supports a combination of a metronome with a chest compression depth measurement for real-time support during CPR. More research is needed on human-machine interface for the design of feedback systems in resuscitation.
引用
收藏
页码:271 / 276
页数:6
相关论文
共 50 条
  • [1] Real-time feedback systems for cardiopulmonary resuscitation training: time for a paradigm shift
    Cortegiani, Andrea
    Baldi, Enrico
    Iozzo, Pasquale
    Vitale, Filippo
    Raineri, Santi Maurizio
    Giarratano, Antonino
    JOURNAL OF THORACIC DISEASE, 2018, 10 (02) : E162 - E163
  • [2] Effect of real-time feedback during cardiopulmonary resuscitation outside hospital: prospective, cluster-randomised trial
    Hostler, David
    Everson-Stewart, Siobhan
    Rea, Thomas D.
    Stiell, Ian G.
    Callaway, Clifton W.
    Kudenchuk, Peter J.
    Sears, Gena K.
    Emerson, Scott S.
    Nichol, Graham
    BRITISH MEDICAL JOURNAL, 2011, 342 : 371
  • [3] Effect of real-time feedback during cardiopulmonary resuscitation training on quality of performances: A prospective cluster-randomized trial
    Kong, So Yeon Joyce
    Song, Kyoung Jun
    Shin, Sang Do
    Ro, Young Sun
    Myklebust, Helge
    Birkenes, Tonje Soraas
    Kim, Tae Han
    Park, Kwan Jin
    HONG KONG JOURNAL OF EMERGENCY MEDICINE, 2020, 27 (04) : 187 - 196
  • [4] Real-Time Audiovisual Feedback Training Improves Cardiopulmonary Resuscitation Performance A Controlled Study
    Eshel, Ron
    Wacht, Oren
    Schwartz, Dagan
    SIMULATION IN HEALTHCARE-JOURNAL OF THE SOCIETY FOR SIMULATION IN HEALTHCARE, 2019, 14 (06): : 359 - 365
  • [5] Smartphone Application to Provide Real-Time Cardiopulmonary Resuscitation Quality Feedback
    Stumpf, Emily
    Ambati, Ravi
    Shekhar, Raj
    Staffa, Steven
    Zurakowski, David
    Sinha, Pranava
    CIRCULATION, 2019, 140
  • [6] A Smartphone application to provide real-time cardiopulmonary resuscitation quality feedback
    Stumpf, Emily
    Ambati, Ravi Tej
    Shekhar, Raj
    Staffa, Steven J.
    Zurakowski, David
    Sinha, Pranava
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2022, 60 : 34 - 39
  • [7] Effectiveness of real-time chest compression feedback devices for individuals experienced in cardiopulmonary resuscitation: a randomized controlled simulation study
    Won, Moonho
    Kim, Jae Hwan
    Ahn, Chiwon
    Lee, Sae Youn
    Oh, Yoonseok
    SIGNA VITAE, 2024, 20 (10) : 1 - 8
  • [8] Real-time feedback systems for improvement of resuscitation quality
    Lukas, R. P.
    Van Aken, H.
    Engel, P.
    Bohn, A.
    ANAESTHESIST, 2011, 60 (07): : 653 - 660
  • [9] Effects of vibration-guided cardiopulmonary resuscitation with a smartwatch versus metronome guidance cardiopulmonary resuscitation during adult cardiac arrest: a randomized controlled simulation study
    Choi, Sungwoo
    Han, Sangsoo
    Chae, Minjung Kathy
    Lee, Young Hwan
    AUSTRALASIAN EMERGENCY CARE, 2021, 24 (04) : 302 - 307
  • [10] Quality of out-of-hospital cardiopulmonary resuscitation with real time automated feedback: A prospective interventional study
    Kramer-Johansen, Jo
    Myklebust, Helge
    Wik, Lars
    Fellows, Bob
    Svensson, Leif
    Sorebo, Hallstein
    Steen, Petter Andreas
    RESUSCITATION, 2006, 71 (03) : 283 - 292