Sensory stimulation (TENS): effects of parameter manipulation on mechanical pain thresholds in healthy human subjects

被引:122
|
作者
Chesterton, LS
Barlas, P [1 ]
Foster, NE
Lundeberg, T
Wright, CC
Baxter, GD
机构
[1] Univ Keele, Dept Physiotherapy Studies, Keele ST5 5BG, Staffs, England
[2] Karolinska Inst, Dept Physiol & Pharmacol, Stockholm, Sweden
[3] Coventry Univ, Sch Hlth & Social Sci, Coventry, W Midlands, England
[4] Univ Ulster, Sch Rehabil Sci, Jordanstown, North Ireland
关键词
transcutaneous electrical nerve stimulation; electrostimulation; parameters; mechanical pain; humans;
D O I
10.1016/S0304-3959(02)00118-5
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Transcutaneous electrical nerve stimulation (TENS) is a popular form of electrostimulation. Despite an extensive research base, there remains no consensus regarding the parameter selection required to achieve maximal hypoalgesic effects. The aim of this double blind, sham-controlled study was to investigate the relative hypoalgesic effects of different TENS parameters (frequency, intensity and stimulation site) upon experimentally induced mechanical pain. Two hundred and forty participants were recruited in order to provide statistical analysis with 80% power at alpha = 0.05. Subjects were randomised to one of the six TENS groups, a control, and a sham TENS group (n = 30, 15 males, 15 females, per group). TENS groups differed in their combinations of stimulation; frequency (4 or 110 Hz), intensity ('to tolerance' or 'strong but comfortable') and stimulation site (segmental - over the distribution of the radial nerve or, extrasegmental - over acupuncture point 'gall bladder 34', or a combination of both segmental and extrasegmental). Pulse duration was fixed at 200 mus. Stimulation was delivered for 30 min and subjects were then monitored for a further 30 min. Mechanical pain threshold (MPT) was measured using a pressure algometer and taken from the first dorsal interosseous muscle of the dominant hand, ipsilateral to the stimulation site. MPT measures were taken, at baseline, and at 10-min intervals for 60 min. Difference scores were analysed using repeated measures and one-way ANOVA and relevant post hoc tests. Low frequency, high intensity, extrasegmental stimulation produced a rapid onset hypoalgesic effect, which increased during the stimulation period (P < 0.0005 control and sham) and was sustained for 30 min post-stimulation (P < 0.0005(control), P = 0.024(sham)). Whilst high frequency, 'strong but comfortable' intensity, segmental stimulation produced comparable hypoalgesic levels during stimulation, this effect was not sustained post-stimulation. Stimulation at a combination of the two sites did not produce any greater hypoalgesic, effects. These results may have implications for the clinical use of sensory stimulation. (C) 2002 International Association for the Study of Pain. Published by Elsevier Science B.V. All rights reserved.
引用
收藏
页码:253 / 262
页数:10
相关论文
共 50 条
  • [1] Effects of TENS frequency, intensity and stimulation site parameter manipulation on pressure pain thresholds in healthy human subjects
    Chesterton, LS
    Foster, NE
    Wright, CC
    Baxter, GD
    Barlas, P
    PAIN, 2003, 106 (1-2) : 73 - 80
  • [2] The effects of TENS, heat, and cold on the pain thresholds induced by mechanical pressure in healthy volunteers
    Solomon, J
    Shebshacvich, V
    Adler, R
    Vulfsons, S
    Rosenbach, A
    Eisenberg, E
    NEUROMODULATION, 2003, 6 (02): : 102 - 107
  • [3] Effects of loperamide on pain thresholds in healthy subjects
    Whitehead, WE
    Jones, KR
    Meyer, K
    GASTROENTEROLOGY, 1999, 116 (04) : A1102 - A1102
  • [4] The effects of transcutaneous electrical nerve stimulation (TENS) upon unilateral nerve conduction, mechanical pain and tactile thresholds in humans
    Walsh, DM
    Baxter, GD
    Allen, JM
    JOURNAL OF PHYSIOLOGY-LONDON, 1997, 501P : P46 - P46
  • [5] Deep pain thresholds in the distal limbs of healthy human subjects
    Rolke, R
    Campbell, KA
    Magerl, W
    Treede, RD
    EUROPEAN JOURNAL OF PAIN, 2005, 9 (01) : 39 - 48
  • [6] The effects of transcutaneous electrical nerve stimulation (TENS) parameters upon bilateral nerve conduction, mechanical pain and tactile thresholds in humans
    Lowe, AS
    McCormack, K
    Walsh, DM
    Baxter, GD
    Allen, JM
    JOURNAL OF PHYSIOLOGY-LONDON, 1996, 495P : P131 - P131
  • [7] Is mechanical pain threshold after transcutaneous electrical nerve stimulation (TENS) increased locally and unilaterally? A randomized placebocontrolled trial in healthy subjects
    Aarskog, Reidar
    Johnson, Mark I.
    Demmink, Jan Hendrik
    Lofthus, Anne
    Iversen, Vegard
    Lopes-Martins, Rodrigo
    Joensen, Jon
    Bjordal, Jan M.
    PHYSIOTHERAPY RESEARCH INTERNATIONAL, 2007, 12 (04) : 251 - 263
  • [8] BARORECEPTOR STIMULATION - PAIN PERCEPTION AND SENSORY THRESHOLDS
    DROSTE, C
    KARDOS, A
    BRODY, S
    GREENLEE, MW
    ROSKAMM, H
    RAU, H
    BIOLOGICAL PSYCHOLOGY, 1994, 37 (02) : 101 - 113
  • [9] Effects of Spinal Cord Stimulation on Pain Thresholds and Sensory Perceptions in Chronic Pain Patients
    Ahmed, Shihab U.
    Zhang, Yi
    Chen, Lucy
    St Hillary, Kristin
    Cohen, Abigail
    Trang Vo
    Houghton, Mary
    Mao, Jianren
    NEUROMODULATION, 2015, 18 (05): : 355 - 360
  • [10] BDNF as an effect modifier for gender effects on pain thresholds in healthy subjects
    Stefani, Luciana Cadore
    da Silva Torres, Iraci Lucena
    Custodio de Souza, Izabel Cristina
    Rozisky, Joanna Ripoll
    Fregni, Felipe
    Caumo, Wolnei
    NEUROSCIENCE LETTERS, 2012, 514 (01) : 62 - 66