Coupling one-dimensional arterial blood flow to three-dimensional tissue perfusion models for in silico trials of acute ischaemic stroke

被引:29
|
作者
Padmos, Raymond M. [1 ]
Jozsa, Tamas, I [2 ]
El-Bouri, Wahbi K. [2 ]
Konduri, Praneeta R. [3 ,4 ]
Payne, Stephen J. [2 ]
Hoekstra, Alfons G. [1 ]
机构
[1] Univ Amsterdam, Fac Sci, Inst Informat, Computat Sci Lab, Sci Pk 904, NL-1098 XH Amsterdam, Netherlands
[2] Univ Oxford, Inst Biomed Engn, Dept Engn Sci, Parks Rd, Oxford OX1 3PJ, England
[3] Amsterdam UMC, Locat AMC, Dept Radiol & Nucl Med, NL-1105 AZ Amsterdam, Netherlands
[4] Amsterdam UMC, Locat AMC, Biomed Engn & Phys, NL-1105 AZ Amsterdam, Netherlands
关键词
one-dimensional blood flow model; perfusion territories; cerebral perfusion; acute ischaemic stroke; MIDDLE CEREBRAL-ARTERY; PULSATILITY INDEX; HUMAN BRAIN; STIFFNESS; TERRITORIES; BEHAVIOR; NETWORK; LIFE; 1-D;
D O I
10.1098/rsfs.2019.0125
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
An acute ischaemic stroke is due to the sudden blockage of an intracranial blood vessel by an embolized thrombus. In the context of setting up in silico trials for the treatment of acute ischaemic stroke, the effect of a stroke on perfusion and metabolism of brain tissue should be modelled to predict final infarcted brain tissue. This requires coupling of blood flow and tissue perfusion models. A one-dimensional intracranial blood flow model and a method to couple this to a brain tissue perfusion model for patient-specific simulations is presented. Image-based patient-specific data on the anatomy of the circle of Willis are combined with literature data and models for vessel anatomy not visible in the images, to create an extended model for each patient from the larger vessels down to the pial surface. The coupling between arterial blood flow and tissue perfusion occurs at the pial surface through the estimation of perfusion territories. The coupling method is able to accurately estimate perfusion territories. Finally, we argue that blood flow can be approximated as steady-state flow at the interface between arterial blood flow and tissue perfusion to reduce the cost of organ-scale simulations.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] IMPLICIT COUPLING OF ONE-DIMENSIONAL AND THREE-DIMENSIONAL BLOOD FLOW MODELS WITH COMPLIANT VESSELS
    Malossi, A. Cristiano I.
    Blanco, Pablo J.
    Crosetto, Paolo
    Deparis, Simone
    Quarteroni, Alfio
    MULTISCALE MODELING & SIMULATION, 2013, 11 (02): : 474 - 506
  • [2] One-dimensional and three-dimensional models of cerebrovascular flow
    Moore, SM
    Moorhead, KT
    Chase, JG
    David, T
    Fink, J
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (03): : 440 - 449
  • [3] Optimization of topological complexity for one-dimensional arterial blood flow models
    Fossan, Fredrik E.
    Mariscal-Harana, Jorge
    Alastruey, Jordi
    Hellevik, Leif R.
    JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2018, 15 (149)
  • [5] One-dimensional models for blood flow in arteries
    Formaggia, L
    Lamponi, D
    Quarteroni, A
    JOURNAL OF ENGINEERING MATHEMATICS, 2003, 47 (3-4) : 251 - 276
  • [6] One-dimensional models for blood flow in arteries
    Luca Formaggia
    Daniele Lamponi
    Alfio Quarteroni
    Journal of Engineering Mathematics, 2003, 47 : 251 - 276
  • [7] ON THE MODELING OF DISTRIBUTED OUTFLOW IN ONE-DIMENSIONAL MODELS OF ARTERIAL BLOOD-FLOW
    SMIT, CH
    ZEITSCHRIFT FUR ANGEWANDTE MATHEMATIK UND PHYSIK, 1981, 32 (04): : 408 - 420
  • [8] Comparison of one-dimensional and three-dimensional models for the energy accommodation coefficient
    Özer, A
    Manson, JR
    SURFACE SCIENCE, 2002, 502 : 352 - 357
  • [9] On the physical consistency between three-dimensional and one-dimensional models in haemodynamics
    Formaggia, Luca
    Quarteroni, Alfio
    Vergara, Christian
    JOURNAL OF COMPUTATIONAL PHYSICS, 2013, 244 : 97 - 112
  • [10] One-dimensional and three-dimensional coupling simulation research of centrifugal cascade hydraulics
    Yan Hao
    Che Jun
    Chen Siyu
    KERNTECHNIK, 2022, 87 (02) : 176 - 186