Very high position resolution gamma imaging with resistive plate chambers

被引:4
|
作者
Blanco, A. [1 ]
Carolino, N.
Correia, C. M. B. A.
Fazendeiro, L.
Ferreira, Nuno C.
Marques, M. F. Ferreira
Marques, R. Ferreira
Fonte, P.
Gil, C.
Macedo, M. P.
机构
[1] Lab Instrumentacao & Fis Expt Particulas, LIP, P-3004516 Coimbra, Portugal
[2] Univ Coimbra, CEI, P-3004516 Coimbra, Portugal
[3] Univ Coimbra, Fac Med, IBILI, P-3000 Coimbra, Portugal
[4] Univ Coimbra, Dept Fis, ICEMS, P-3004516 Coimbra, Portugal
[5] ISEC, P-3031199 Coimbra, Portugal
[6] Univ Coimbra, Dept Fis, P-3004516 Coimbra, Portugal
关键词
gaseous detectors; photodetectors; RPC; PET;
D O I
10.1016/j.nima.2006.05.074
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this study we present experimental results from a first prototype of a positron emission tomography system based on the resistive plate chamber (RPC) technology. The system is composed of two counting heads, each one containing 16 single-gap RPC detectors capable of detecting the photon interaction point in the transaxial plane. Uniformity studies were performed for image resolution and sensitivity, yielding a rather uniform image resolution close to 0.3 mm FWHM across the field of view. The contribution of the photons noncolinearity effect to the intrinsic spatial resolution was also studied, causing a variation from 0.52 to 0.63mm when the system diameter ranges from 60 to 120mm, in agreement with calculations. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:96 / 99
页数:4
相关论文
共 50 条
  • [1] High resolution muon tracking with resistive plate chambers
    Baesso, P.
    Cussans, D.
    Davies, J.
    Glaysher, P.
    Thomay, C.
    Vassallo, C.
    Velthuis, J.
    Quillin, S.
    Robertson, S.
    Steer, C.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [2] Angular resolution of stacked resistive plate chambers
    Samuel, Deepak
    Onikeri, Pratibha B.
    Murgod, Lakshmi P.
    JOURNAL OF COSMOLOGY AND ASTROPARTICLE PHYSICS, 2017, (01):
  • [3] High rate resistive plate chambers
    Zeballos, EC
    Crotty, I
    Hatzifotiadou, D
    Valverde, JL
    Neupane, S
    Singh, S
    Williams, MCS
    Zichichi, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 367 (1-3): : 388 - 393
  • [4] Resistive Plate Chambers for imaging calorimetry - The DHCAL
    Repond, J.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [5] Accurate timing of gamma rays with high-rate Resistive Plate Chambers
    Lopes, L.
    Pereira, A.
    Fonte, P.
    Marques, R. Ferreira
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 573 (1-2): : 4 - 7
  • [6] Resistive plate chambers working at high rate
    Abbrescia, M
    Bacci, C
    Bencze, C
    Camarri, P
    Cardarelli, R
    Ceradini, F
    Ciapetti, G
    DiCiaccio, A
    Iaselli, G
    Lacava, F
    Makeev, V
    Nisati, A
    Petrolo, E
    Pontecorvo, L
    Radermacher, E
    Santonico, R
    Seez, C
    Veneziano, S
    Verzocchi, M
    Zaets, VG
    Zanello, L
    Zito, G
    NUCLEAR PHYSICS B, 1995, : 218 - 221
  • [7] Resistive Plate Chambers in high energy experiments
    Ratti, SP
    HIGH ENERGY PHYSICS, VOLS I AND II, 2001, : 1261 - 1263
  • [8] Study on the position resolution of resistive plate chamber
    Ye Jin
    Cheng Hanping
    Yue Qian
    Li Yuanjing
    Li Jin
    Wang Yi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 591 (02): : 411 - 416
  • [9] The physics of Resistive Plate Chambers
    Riegler, W
    Lippmann, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 518 (1-2): : 86 - 90
  • [10] Time resolution of resistive plate chambers investigated with 10 MeV electrons
    Paradela, C.
    Ayyad, Y.
    Benlliure, J.
    Casarejos, E.
    Duran, I.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 735 : 94 - 101