Simplified follow-up after early medical abortion: 12-month experience of a telephone call and self-performed low-sensitivity urine pregnancy test

被引:38
|
作者
Michie, Lucy [1 ,2 ]
Cameron, Sharon T. [1 ,2 ]
机构
[1] Univ Edinburgh, Dept Reprod & Dev Sci, Edinburgh EH16 5SU, Midlothian, Scotland
[2] Royal Infirm Edinburgh NHS Trust, Simpson Ctr Reprod Hlth, Edinburgh EH16 4SA, Midlothian, Scotland
关键词
Termination of pregnancy; Medical termination of pregnancy; Telephone follow-up; Postabortal; FINAL STAGE; HOME; ALTERNATIVES;
D O I
10.1016/j.contraception.2014.01.010
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: The objective was to determine if simplified follow-up after early medical abortion, consisting of a telephone call 2 weeks after the procedure plus a self-performed low-sensitivity urine pregnancy (LSUP) test, was successful for screening for ongoing pregnancies in the year following its introduction as standard service. Study design: A retrospective computerized database review of 1084 women at a hospital abortion service in Edinburgh, UK, who had a medical abortion 9 weeks) and went home to expel the pregnancy was performed. Women who screened 'positive' at telephone follow-up on the basis of ongoing pregnancy symptoms, scant bleeding or LSUP test result were scheduled for an ultrasound. The main outcome measures were the proportion of women scheduled for telephone follow-up successfully contacted and the proportion of ongoing pregnancies detected. Results: A total of 943 women were scheduled for telephone follow-up. Ten women presented to the hospital before the time of the follow-up call. Of the remaining 933 women, 656 [70%, 95% confidence interval (Cl) 67.7-73.2] were successfully contacted. Five hundred seventy-three (87%, 95% CI 84.5-89.7) of those contacted screened 'negative'; no false negatives occurred. Eighty-three (13%, 95% CI 10.2-15.5) screened 'positive,' and of those, three had ongoing pregnancies. Of the 277 (30%, 95% CI 26.7-32.7) who were not contacted, two ongoing pregnancies occurred. The sensitivity of telephone follow-up with LSUP to detect ongoing pregnancy was 100% (95% CI 30.9%-100%), and specificity was 88% (95% CI 84.9%-90.1%). The negative predictive value was 100% (95% CI 99.1%-100%), and positive predictive value was 3.6% (95% CI 0.9%-10.9%). Conclusion: A telephone call and LSUP test at 2 weeks are suitable as a standard method of follow-up for screening for ongoing pregnancy after early medical abortion. Implications statement: For most women, a routine clinic follow-up after early medical abortion (to exclude ongoing pregnancy) can be replaced with a telephone call and a self-performed LSUP test at 2 weeks postprocedure. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:440 / 445
页数:6
相关论文
共 7 条
  • [1] Telephone follow-up and self-performed urine pregnancy testing after early medical abortion: a service evaluation
    Cameron, Sharon T.
    Glasier, Anna
    Dewart, Helen
    Johnstone, Anne
    Burnside, Audrey
    [J]. CONTRACEPTION, 2012, 86 (01) : 67 - 73
  • [2] Feasibility of self-performed urine pregnancy testing for follow-up after medical abortion
    Hassoun, Danielle
    Perin, Ines
    Hien, Helena
    Demars, Helene Herman
    [J]. EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2016, 197 : 174 - 178
  • [3] Telephone follow-up after early medical abortion using Australia's first low sensitivity urine pregnancy test
    Melville, Catriona
    Goldstone, Philip
    Moosa, Nisreen
    [J]. AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 2023, 63 (06): : 797 - 802
  • [4] Self-assessment of success of early medical abortion using a self-performed urine pregnancy test
    Cameron, Sharon
    Rowlands, Sam
    Gemzell-Danielsson, Kristina
    [J]. EUROPEAN JOURNAL OF CONTRACEPTION AND REPRODUCTIVE HEALTH CARE, 2019, 24 (04): : 319 - 321
  • [5] Simplified follow-up after medical abortion using a low-sensitivity urinary pregnancy test and a pictorial instruction sheet in Rajasthan, India – study protocol and intervention adaptation of a randomised control trial
    Mandira Paul
    Kirti Iyengar
    Sharad Iyengar
    Kristina Gemzell-Danielsson
    Birgitta Essén
    Marie Klingberg-Allvin
    [J]. BMC Women's Health, 14
  • [6] Simplified follow-up after medical abortion using a low-sensitivity urinary pregnancy test and a pictorial instruction sheet in Rajasthan, India study protocol and intervention adaptation of a randomised control trial
    Paul, Mandira
    Iyengar, Kirti
    Iyengar, Sharad
    Gemzell-Danielsson, Kristina
    Essen, Birgitta
    Klingberg-Allvin, Marie
    [J]. BMC WOMENS HEALTH, 2014, 14
  • [7] Acceptability and feasibility of phone follow-up with a semiquantitative urine pregnancy test after medical abortion in Moldova and Uzbekistan
    Platais, Ingrida
    Tsereteli, Tamar
    Comendant, Rodica
    Kurbanbekoya, Dilfuza
    Winikoff, Beverly
    [J]. CONTRACEPTION, 2015, 91 (02) : 178 - 183