Influence of a building's integrated-photovoltaics on heating and cooling loads

被引:108
|
作者
Wang, Yiping [1 ]
Tian, Wei [1 ]
Ren, Jianbo [1 ]
Zhu, Li [1 ]
Wang, Qingzhao [1 ]
机构
[1] Tianjin Univ, Sch Chem Engn & Technol, Tianjin 300072, Peoples R China
关键词
BIPV; cooling load; heating load; heat transfer;
D O I
10.1016/j.apenergy.2005.10.002
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Building integrated photovoltaics (BIPV) has the potential to become a major source of renewable energy in the urban environment. BIPV has significant influence on the heat transfer through the building envelope because of the change of the thermal resistance by adding or replacing the building elements. Four different roofs are used to assess the impacts of BIPV on the building's heating-and-cooling loads; namely ventilated air-gap BIPV, non-ventilated (closed) air-gap BIPV, closeroof mounted BIPV, and the conventional roof with no PV and no air gap. One-dimensional transient models of four cases are derived to evaluate the PV performances and building cooling-and-heating loads across the different roofs in order to select the appropriate PV building integration method in Tianjin, China. The simulation results show that the PV roof with ventilated air-gap is suitable for the application in summer because this integration leads to the low cooling load and high PV conversion efficiency. The PV roof with ventilation air-gap has a high time lag and small decrement factor in comparison with other three roofs and has the same heat gain as the cool roof of absorptance 0.4. In winter, BIPV of non-ventilated air gap is more appropriate due to the combination of the low heating-load through the PV roof and high PV electrical output. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:989 / 1003
页数:15
相关论文
共 50 条
  • [1] Influence of insulation configuration on heating and cooling loads in a continuously used building
    Kossecka, E
    Kosny, J
    [J]. ENERGY AND BUILDINGS, 2002, 34 (04) : 321 - 331
  • [2] Comfort air temperature influence on heating and cooling loads of a residential building
    Stanciu, C.
    Soriga, I.
    Gheorghian, A. T.
    Stanciu, D.
    [J]. 7TH INTERNATIONAL CONFERENCE ON ADVANCED CONCEPTS IN MECHANICAL ENGINEERING, 2016, 147
  • [3] Simulation Analysis of a Ventilated Building Integrated-Photovoltaics Air-Gap Duct System for Natural Ventilation of a Building
    Zarmehr, Arash
    Kider, Joseph T., Jr.
    [J]. PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA, 2020, : 724 - 731
  • [4] An improved bin method for building heating and cooling loads
    Yan, Yongmin
    Zhang, Guoqiang
    Zhou, Jin
    Liu, Hongcheng
    [J]. PROCEEDINGS OF THE 5TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I AND II, 2007, : 66 - 72
  • [5] A computer analysis of heating and cooling loads for different types of building
    Stritih, U
    Muhic, S
    Novak, P
    [J]. STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2000, 46 (08): : 503 - 508
  • [6] Coloured building integrated photovoltaics: Influence on energy efficiency
    Royset, Arne
    Kolas, Tore
    Jelle, Bjorn Petter
    [J]. ENERGY AND BUILDINGS, 2020, 208
  • [7] Building-integrated photovoltaics: Effect on the cooling load component of building façades
    Yang, H.
    Burnett, J.
    Zhu, Z.
    [J]. Building Services Engineering Research and Technology, 2001, 22 (03) : 157 - 165
  • [8] Building Integrated Photovoltaics
    不详
    [J]. BAUINGENIEUR, 2016, 91 : A20 - A20
  • [9] Building Integrated Photovoltaics
    Siebert, Barbara
    [J]. CHALLENGING GLASS 3, 2012, : 971 - 979
  • [10] Uncertainty and sensitivity analysis of cooling and heating loads for building energy planning
    Zhu, Li
    Zhang, Jiqiang
    Gao, Yuzhe
    Tian, Wei
    Yan, Zhexing
    Ye, Xueshun
    Sun, Yong
    Wu, Cuigu
    [J]. JOURNAL OF BUILDING ENGINEERING, 2022, 45