Detection of lung perfusion abnormalities using computed tomography in a porcine model of pulmonary embolism

被引:48
|
作者
Screaton, NJ
Coxson, HO
Kalloger, SE
Baile, EM
Nakano, Y
Hiorns, M
Mayo, JR
机构
[1] Vancouver Gen Hosp, Dept Radiol, Vancouver, BC V5Z 1M9, Canada
[2] Univ British Columbia, MaDonald Res Labs, iCapture Ctr, St Pauls Hosp, Vancouver, BC, Canada
关键词
lung perfusion; computed tomography; pulmonary embolism;
D O I
10.1097/00005382-200301000-00002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to identify perfusion defects of the lung using computed tomography (CT). A balloon catheter was placed in a lobar pulmonary artery of six anesthetized, ventilated juvenile pigs to simulate occlusive segmental embolus. Contrast medium was injected via a central venous catheter at rates of 1.5, 3, 4.5, and 9 ml/s in each pig. A 40-second single-level cine CT was acquired distal to the inflated balloon during suspended inspiration. Three computer-manipulated images (time to maximal enhancement, change in maximal attenuation, maximal contrast minus precontrast subtraction.) were generated using custom software and compared with the unmodified maximal enhancement and precontrast images. Two independent observers identified perfusion defects and scored the level of confidence (5-point scale) on all five images, Regions of interest were drawn in perfused and nonperfused lung and time-attenuation curves were generated. Perfusion defects were accurately (99.8 +/- 0.3%) and confidently (4.5 +/- 0.6) detected and there was excellent interobserver agreement (Kappa 0.99 +/- 0.02) on all computer-manipulated images. There was a significant increase in confidence (p < 0.05) between contrast medium injection rates of 1.5 and 9 ml/s. A linear relationship exists (r(2) = 0.88) between injection rate and change in maximal attenuation. In conclusion, perfusion defects of the lung are seen using computer-manipulated CT images.
引用
收藏
页码:14 / 20
页数:7
相关论文
共 50 条
  • [1] CT perfusion image of the lung - Value in the detection of pulmonary embolism in a porcine model
    Chung, MJ
    Goo, JM
    Im, JG
    Lee, KS
    Kim, KG
    Park, JH
    [J]. INVESTIGATIVE RADIOLOGY, 2004, 39 (10) : 633 - 640
  • [2] Computed tomography scan versus ventilation-perfusion lung scan in the detection of pulmonary embolism
    Cueto, SM
    Cavanaugh, SH
    Benenson, RS
    Redclift, MS
    [J]. JOURNAL OF EMERGENCY MEDICINE, 2001, 21 (02): : 155 - 164
  • [3] Ventilation perfusion scan or computed tomography pulmonary angiography for the detection of pulmonary embolism?
    Hitchen, Sophy
    James, Jacqueline
    Thachil, Jecko
    [J]. EUROPEAN JOURNAL OF INTERNAL MEDICINE, 2016, 32 : E26 - E27
  • [4] Diagnostic value of perfusion lung scintigraphy in SPECT/CT and computed tomography pulmonary angiography for detection of pulmonary embolism
    Naydenska, Sevda
    Zlatareva, Dora
    Stancheva, Bilyana
    Smilkova, Elina
    Bilyukov, Radoslav
    Pencheva, Ventsislava
    Miletieva, Daniela
    Mondeshki, Tzanko
    Petrova, Daniela
    Georgiev, Ognian
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2017, 50
  • [5] Comparison Between Chest Computed Tomography and Perfusion Lung Scan Images in Pulmonary Embolism
    Corsi, G.
    Romei, C.
    Marconi, L.
    Falaschi, F.
    Palla, A.
    Celi, A.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 199
  • [6] Computed tomography densitometry of the lung: a method to assess perfusion defects in acute pulmonary embolism
    Groell, R
    Peichel, KH
    Uggowitzer, MM
    Schmid, F
    Hartwagner, K
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 1999, 32 (03) : 192 - 196
  • [7] Discrepancy between Dual-Energy Computed Tomography Lung Perfusion Blood Volume and Lung Perfusion Single-Photon Emission Computed Tomography/Computed Tomography Images in Pulmonary Embolism
    Koike, Hirofumi
    Sueyoshi, Eijun
    Nagayama, Hiroki
    Ashizawa, Kazuto
    Sakamoto, Ichiro
    Uetani, Masataka
    Kudo, Takashi
    Ikeda, Satoshi
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2014, 189 (12) : E71 - E72
  • [8] Ventilation/Perfusion SPECT lung scintigraphy and computed tomography pulmonary angiography in patients with clinical suspicion of pulmonary embolism
    Ibanez-Bravo, S.
    Banzo, I.
    Quirce, R.
    Martinez-Rodriguez, I.
    Jimenez-Bonilla, J.
    Martinez-Amador, N.
    Parra, J. A.
    Gonzalez-Macias, J.
    Carril, J. M.
    [J]. REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2016, 35 (04): : 215 - 220
  • [9] Frequency of computed tomography abnormalities in patients with chronic thromboembolic pulmonary hypertension: a comparative study between lung perfusion scan and computed tomography pulmonary angiography
    Fathala, Ahmed
    Aldurabi, Alaa
    [J]. MULTIDISCIPLINARY RESPIRATORY MEDICINE, 2021, 16
  • [10] Pulmonary embolism in COVID-19: Ventilation and perfusion computed tomography
    Ierardi, Anna Maria
    Angileri, Salvatore Alessio
    Arrichiello, Antonio
    Di Meglio, Letizia
    Gurgitano, Martina
    Roda, Giovanni Maria
    Carrafiello, Gianpaolo
    [J]. IDCASES, 2020, 21