An experimental analysis of the effect of refrigerant charge level on an automotive refrigeration system

被引:24
|
作者
Ratts, EB
Brown, JS
机构
[1] Univ Michigan, Dearborn, MI 48128 USA
[2] Catholic Univ Amer, Washington, DC 20064 USA
关键词
automotive; refrigeration; charge; entropy; generation;
D O I
10.1016/S1290-0729(00)00208-8
中图分类号
O414.1 [热力学];
学科分类号
摘要
The performance of an automotive refrigeration system is dependent on the refrigerant charge level. Due to inevitable leaks in the system, the amount of refrigerant will decrease over time and thus ultimately reduce the system's performance. A reduction in the amount of refrigerant charge results in excessive compressor cycling, a lower condenser pressure, a higher refrigeration temperature, and an increase in the amount of superheat. This paper identifies and quantifies the individual component losses in an automotive refrigeration system as a function of the refrigerant charge level. A second law analysis, based on nondimensional entropy generation, is carried out to quantify the thermodynamic losses. A passenger vehicle with a cycling-clutch, orifice tube refrigeration system was instrumented to measure various temperatures and pressures, and relative humidity. The data were collected at idle conditions. Thermodynamic equations, which are used to determine the system's thermal performance, are presented. The system's second law efficiency increases 26% as the amount of refrigerant charge decreases by 44%. Also the individual component losses are quantified as a function of the refrigerant charge level. The compressor and the condenser losses account for the largest percentage of the total losses, and are of similar magnitude. The evaporator-accumulator and the orifice tube losses account for a smaller percentage of the total losses, and are also of similar magnitude. With a reduction in the refrigerant charge level of 44%, the losses in the compressor, the condenser, the evaporator-accumulator, and the orifice tube decrease 13 %, 8 %, 10 %, and 33 %, respectively. (C) 2000 Editions scientifiques et medicales Elsevier SAS.
引用
收藏
页码:592 / 604
页数:13
相关论文
共 50 条
  • [1] AN EXPERIMENTAL INVESTIGATION OF THE EFFECT OF REFRIGERANT CHARGE LEVEL ON AN AUTOMOTIVE AIR CONDITIONING SYSTEM
    Atik, Kemal
    Aktas, Abdurrazzak
    [J]. ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2011, 31 (01) : 11 - 17
  • [2] Determination of a Vapor Compression Refrigeration System Refrigerant Charge
    Yang Chun-Xin
    Dang Chao-Bin (Institute of Air Conditioning and Refrigeration Engineering
    [J]. Journal of Thermal Science, 1995, (03) : 162 - 168
  • [3] AN EXPERIMENTAL ANALYSIS OF THE EFFECT OF REFRIGERANT CHARGE LEVEL AND OUTDOOR CONDITION ON A WINDOW AIR CONDITIONER
    Raj, M. Herbert
    Lal, D. Mohan
    [J]. THERMAL SCIENCE, 2010, 14 (04): : 1121 - 1138
  • [4] Refrigeration systems with minimized refrigerant charge: system design and performance
    Primal, F
    Lundqvist, P
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2005, 219 (E2) : 127 - 137
  • [5] Refrigeration systems with minimum charge of refrigerant
    Palm, Bjorn
    [J]. APPLIED THERMAL ENGINEERING, 2007, 27 (10) : 1693 - 1701
  • [6] Experimental investigation of the parameters influencing refrigerant migration in a refrigeration system
    Kocaturk, Serdar
    Guldali, Yalcin
    Egrican, A. Nilufer
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION 2007, VOL 8, PTS A AND B: HEAT TRANSFER, FLUID FLOWS, AND THERMAL SYSTEMS, 2008, : 1409 - 1419
  • [7] EXPERIMENTAL STUDY ON SINGLE-REFRIGERANT CASCADE REFRIGERATION SYSTEM
    Kong, Shuai
    Yang, Yongan
    [J]. 5TH IIR INTERNATIONAL CONFERENCE ON SUSTAINABILITY AND THE COLD CHAIN, 2018, : 340 - 347
  • [8] Refrigeration system development with limited charge of flammable Refrigerant, R-290
    Jones, Alan
    Wolf, Arne
    Kwark, Sang Muk
    [J]. THERMAL SCIENCE AND ENGINEERING PROGRESS, 2023, 34
  • [9] EXPERIMENTAL ANALYSIS ON VAPOUR COMPRESSION REFRIGERATION SYSTEM USING NANOLUBRICANT WITH HFC-134a REFRIGERANT
    Babu, A. Manoj
    Nallusamy, S.
    Rajan, K.
    [J]. NANO HYBRIDS, 2015, 9 : 33 - 43
  • [10] Numerical and experimental study of the transient behavior of a domestic vapor compression refrigeration system - Influence of refrigerant charge and ambient temperature
    Gardenghi, Alvaro Roberto
    Lacerda, Jonatas Ferreira
    Tibirica, Cristiano Bigonha
    Cabezas-Gomez, Luben
    [J]. APPLIED THERMAL ENGINEERING, 2021, 190