Success rates for computed tomography-guided musculoskeletal biopsies performed using a low-dose technique

被引:3
|
作者
Motamedi, Kambiz [1 ]
Levine, Benjamin D. [1 ]
Seeger, Leanne L. [1 ]
McNitt-Gray, Michael F. [1 ]
机构
[1] UCLA Hlth Syst, Radiol, Los Angeles, CA 90095 USA
关键词
CT-guided biopsy; Low-dose CT; Bone and soft tissue tumors; CT; REDUCTION;
D O I
10.1007/s00256-014-1892-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To evaluate the success rate of a low-dose (50 % mAs reduction) computed tomography (CT) biopsy technique. This protocol was adopted based on other successful reduced-CT radiation dose protocols in our department, which were implemented in conjunction with quality improvement projects. The technique included a scout view and initial localizing scan with standard dose. Additional scans obtained for further guidance or needle adjustment were acquired by reducing the tube current-time product (mAs) by 50 %. The radiology billing data were searched for CT-guided musculoskeletal procedures performed over a period of 8 months following the initial implementation of the protocol. These were reviewed for the type of procedure and compliance with the implemented protocol. The compliant CT-guided biopsy cases were then retrospectively reviewed for patient demographics, tumor pathology, and lesion size. Pathology results were compared to the ultimate diagnoses and were categorized as diagnostic, accurate, or successful. Of 92 CT-guided procedures performed during this period, two were excluded as they were not biopsies (one joint injection and one drainage), 19 were excluded due to non-compliance (operators neglected to follow the protocol), and four were excluded due to lack of available follow-up in our electronic medical records. A total of 67 compliant biopsies were performed in 63 patients (two had two biopsies, and one had three biopsies). There were 32 males and 31 females with an average age of 50 (range, 15-84 years). Of the 67 biopsies, five were non-diagnostic and inaccurate and thus unsuccessful (7 %); five were diagnostic but inaccurate and thus unsuccessful (7 %); 57 were diagnostic and accurate thus successful (85 %). These results were comparable with results published in the radiology literature. The success rate of CT-guided biopsies using a low-dose protocol is comparable to published rates for conventional dose biopsies. The implemented low-dose protocol did not change the success rate of CT-guided musculoskeletal biopsies.
引用
收藏
页码:1599 / 1603
页数:5
相关论文
共 50 条
  • [1] Success rates for computed tomography-guided musculoskeletal biopsies performed using a low-dose technique
    Kambiz Motamedi
    Benjamin D. Levine
    Leanne L. Seeger
    Michael F. McNitt-Gray
    [J]. Skeletal Radiology, 2014, 43 : 1599 - 1603
  • [2] COMPUTED TOMOGRAPHY-GUIDED RETROPERITONEAL BIOPSIES
    KNELSON, M
    HAAGA, J
    LAZARUS, H
    GHOSH, C
    ABDULKARIM, F
    SORENSON, K
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 1989, 7 (08) : 1169 - 1173
  • [3] Computed tomography-guided biopsies in children: accuracy, efficiency and dose usage
    Gruber-Rouh, Tatjana
    Thalhammer, Axel
    Klingebiel, Thomas
    Nour-Eldin, Nour-Eldin A.
    Vogl, Thomas. J.
    Eichler, Katrin
    Naguib, Nagy
    Beeres, Martin
    [J]. ITALIAN JOURNAL OF PEDIATRICS, 2017, 43 : 1 - 6
  • [4] Computed tomography-guided biopsies in children: accuracy, efficiency and dose usage
    Tatjana Gruber-Rouh
    Axel Thalhammer
    Thomas Klingebiel
    Nour-Eldin A. Nour-Eldin
    Thomas. J. Vogl
    Katrin Eichler
    Nagy Naguib
    Martin Beeres
    [J]. Italian Journal of Pediatrics, 43
  • [5] FURTHER EXPERIENCE UTILIZING THE GILDENBERG TECHNIQUE FOR COMPUTED TOMOGRAPHY-GUIDED STEREOTAXIC BIOPSIES
    BULLARD, DE
    OSBORNE, D
    BURGER, PC
    NASHOLD, BS
    [J]. NEUROSURGERY, 1986, 19 (03) : 386 - 391
  • [6] Low-Dose Computed Tomography Colonography Technique
    Chang, Kevin J.
    Yee, Judy
    [J]. RADIOLOGIC CLINICS OF NORTH AMERICA, 2018, 56 (05) : 709 - +
  • [7] Computed tomography-guided lung biopsy: A meta-analysis of low-dose and standard-dose protocols
    Zhang, Ping
    Liu, Jing-Mei
    Zhang, Ying-Ying
    Hua, Rong
    Xia, Feng-Fei
    Shi, Yi-Bing
    [J]. JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2021, 17 (03) : 695 - 701
  • [8] Computed tomography-guided needle biopsies in pediatric oncology
    Guimaraes, AC
    Chapchap, P
    de Camargo, B
    Chojniak, R
    [J]. JOURNAL OF PEDIATRIC SURGERY, 2003, 38 (07) : 1066 - 1068
  • [9] Computed tomography-guided percutaneous bone biopsies in outpatients
    Maas, R
    Krupski, G
    Habermann, CR
    Lund, CH
    Steiner, P
    Buecheler, E
    [J]. RADIOLOGY, 1999, 213P : 417 - 417
  • [10] Radiation Dose Reduction in Computed Tomography-Guided Lung Interventions using an Iterative Reconstruction Technique
    Chang, D. H.
    Hiss, S.
    Mueller, D.
    Hellmich, M.
    Borggrefe, J.
    Bunck, A. C.
    Maintz, D.
    Hackenbroch, M.
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2015, 187 (10): : 906 - 914